Fast delivery within 72 Hours

B&R 0PS3050.1

400 to 500 VAC wide-range input2-phase and 3-phase operationReliable supply even if one phase fails in 3-phase operationHigh dielectric strengthCan be connected in parallel for increased capacity and…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

400 to 500 VAC wide-range input2-phase and 3-phase operationReliable supply even if one phase fails in 3-phase operationHigh dielectric strengthCan be connected in parallel for increased capacity and redundancyReliable operation due to long power failure bypass function under full load and high MTBF (>500,000 h)International certification packageWide temperature range from -25 to 70°CClosed metal housing

24 VDC power supply, 3-phase, 5 A, input 400 to 500 VAC, wide range, top-hat rail installation

Specification

Status displayGreen LED (DC OK), threshold value Uout = 21.5 V
Input - Output4 kV AC (type test) 2 kV AC (routine test)
Input - Ground2 kV AC (type test) 2 kV AC (routine test)
Output - Ground500 VDC (routine test)
Connection typeScrew terminal
Wire end sleevesFlexible cables require wire end sleeves in order to fulfill EN 62368 / UL 60950
Flexible0.2 to 2.5 mm² / 16 to 12 AWG
Inflexible0.2 to 2.5 mm² / 16 to 12 AWG
Wire stripping length9 mm (input/output)
CEYes
UKCAYes
CRA (Cyber Resilience Act)Evaluation ongoing
ULcULus E123528 Industrial control equipment
Nominal input voltage2/3x 400 to 500 VAC
Input voltage3x 320 to 575 VAC, 45 to 65 Hz 2x 360 to 575 VAC, 45 to 65 Hz
Input currentApprox. 3x 0.3 A (400 VAC) Approx. 3x 0.3 A (500 VAC) Approx. 2x 0.65 A (400 VAC) Approx. 2x 0.5 A (500 VAC)
Inrush current limiting<15 A
I2t0.2 A2s
Power failure bypass>20 ms (400 VAC) >30 ms (480 VAC)
Switch-on time<1 s (typical)
Leakage current to PE<3.5 mA
Protective circuitTransient surge protection with varistor
Required line fuse for device and line protection2/3x 6 A (characteristic B) 2/3x 10 A (characteristic B) 2/3x 16 A (characteristic B)
Nominal voltage24 VDC ±1%
Output power120 W
Setting range for output voltage22.5 to 29.5 VDC
-25 to 55°C5.0 A
>55°CDerating: 2.5% per °C
Current limitingApprox. 6 A (for short circuit)
Control deviation<1% (static load change 10 to 90%) <2% (dynamic load change 10 to 90%) <0.1% (input voltage change ±10%)
Rise time<2 ms (UOUT (10 to 90%))
Residual ripple<30 mVSS
Switching peaks<30 mVSS
Can be connected in parallelYes, to establish redundancy and increase capacity
Can be connected in seriesNo
Max. capacitive loadUnlimited
Protection against internal overvoltagesYes, limited to <35 VDC
Protective functionsOutput protected against continuous short circuit, open circuit and overload
Power back immunityMax. 35 VDC
Output noise suppressionDevice complies with EN 55011 (class B)
Efficiency>89%
MTBF>500,000 h, per IEC 61709 (SN 29500)
Rated loadMax. 15 W
No-load operationMax. 4 W
HorizontalYes
VerticalNo
Maximum3000 m
Ventilation/CoolingNormal convection, no fan required
Degree of protection per EN 60529IP20
Protection classI, with PE connection
Operation30 g in each direction, per IEC 60068-2-27
Storage-40 to 85°C
Transport-40 to 85°C
Pollution degree2, per EN 50178
Climate category3K3, per EN 60721
MaterialSteel sheet, galvanized Side panels: Aluminum
InstallationEasy top-hat rail installation (NS 35 rails, EN 60715)
Width40 mm
Height130 mm
Depth115 mm
Weight600 g

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “B&R 0PS3050.1”

Your email address will not be published. Required fields are marked *