Fast delivery within 72 Hours
B&R 0PS1025.2
100 to 240 VAC wide-range inputCan be connected in parallel for increased capacity and redundancyReliable operation due to long power failure bypass function under full load and high MTBF (>500,000 h)…
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
From $20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From $40
-
Warranty 1 year
-
Free 30-Day returns
Description
100 to 240 VAC wide-range inputCan be connected in parallel for increased capacity and redundancyReliable operation due to long power failure bypass function under full load and high MTBF (>500,000 h)International certification packageWide temperature range from -25 to 70°CExtra flat designEasy DIN rail or wall mounting
24 VDC power supply, 1-phase, 2.5 A, input 100 to 240 VAC, wide range, top-hat rail installation
Specification
| Status display |
Green LED (DC OK), threshold value Uout = 21.5 V |
|---|---|
| Input - Output |
4 kV AC (type test) |
| Input - Ground |
3.5 kV AC (type test) |
| Output - Ground |
500 VDC (type test) |
| Connection type |
Screw terminal |
| Wire end sleeves |
Flexible cables require wire end sleeves in order to fulfill EN 62368 / UL 60950 |
| Flexible |
0.2 to 2.5 mm² / 24 to 12 AWG |
| Inflexible |
0.2 to 2.5 mm² / 24 to 12 AWG |
| Wire stripping length |
6.5 mm (input/output) |
| CE |
Yes |
| UKCA |
Yes |
| CRA (Cyber Resilience Act) |
Evaluation ongoing |
| UL |
cULus E123528 |
| Nominal input voltage |
100 to 240 VAC |
| Input voltage |
AC 85 to 264 V (wide range), 45 to 65 Hz |
| Input current |
Approx. 0.8 A (120 VAC) |
| Inrush current limiting |
<15 A (typical) |
| I2t |
<0.6 A2s |
| Power failure bypass |
>20 ms (120 VAC) |
| Switch-on time |
<0.5 s |
| Power factor (cos φ) |
0.65 |
| Protective circuit |
Transient surge protection with varistor |
| Internal fuse |
3.15 A slow-blow |
| Required line fuse for line protection |
6 A (characteristic B) |
| Nominal voltage |
24 VDC ±1% |
| Output power |
60 W |
| Setting range for output voltage |
22.5 to 29.5 VDC (>24 VDC power constant) |
| -25 to 40°C |
2.75 A |
| 40 to 55°C |
2.5 A |
| >55°C |
Derating: 2.5% per °C |
| Current limiting |
Max. 4.4 A |
| Control deviation |
<1% (static load change 10 to 90%) |
| Rise time |
<0.5 s (UOUT (10 to 90%)) |
| Residual ripple |
<50 mVpp (at nominal values) |
| Switching peaks |
<50 mVSS (at nominal values) |
| Can be connected in parallel |
Yes, to establish redundancy and increase capacity |
| Can be connected in series |
Yes |
| Protection against internal overvoltages |
Yes, limited to approximately 35 VDC |
| Protective functions |
Output protected against continuous short circuit, open circuit and overload |
| Power back immunity |
Max. 35 VDC |
| Output noise suppression |
Device complies with EN 55011 (class B) |
| Efficiency |
>86% (at 230 VAC and nominal values) |
| MTBF |
>500,000 h, per IEC 61709 (SN 29500) |
| Rated load |
Max. 9.9 W |
| No-load operation |
Max. 0.7 W |
| Maximum |
3000 m |
| Ventilation/Cooling |
Normal convection, no fan required |
| Degree of protection per EN 60529 |
IP20 |
| Protection class |
II |
| Operation |
30 g in each direction, per IEC 60068-2-27 |
| Storage |
-40 to 85°C |
| Transport |
-40 to 85°C |
| Pollution degree |
2, per EN 50178 |
| Climate category |
3K3, per EN 60721 |
| Material |
Polycarbonate |
| Installation |
Easy top-hat rail (NS 35 rails, EN 60715) or wall installation |
| Width |
72 mm |
| Height |
90 mm |
| Depth |
61 mm |
| Weight |
300 g |

Reviews
Clear filtersThere are no reviews yet.