<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Analog inputs Archives - CentralXL | Industrial Marketplace</title>
	<atom:link href="https://centralxl.com/product-category/io-systems/x20-system-io-systems/analog-inputs/feed/" rel="self" type="application/rss+xml" />
	<link>https://centralxl.com/product-category/io-systems/x20-system-io-systems/analog-inputs/</link>
	<description>The Marketplace for Industrial Supply &#38; Demand</description>
	<lastBuildDate>Mon, 22 Dec 2025 11:07:11 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://centralxl.com/wp-content/uploads/2025/10/cropped-centralxl-white-32x32.png</url>
	<title>Analog inputs Archives - CentralXL | Industrial Marketplace</title>
	<link>https://centralxl.com/product-category/io-systems/x20-system-io-systems/analog-inputs/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>B&#038;R X20AP3171</title>
		<link>https://centralxl.com/product/br-x20ap3171/</link>
					<comments>https://centralxl.com/product/br-x20ap3171/#respond</comments>
		
		<dc:creator><![CDATA[sales@partnerplc.com]]></dc:creator>
		<pubDate>Fri, 31 Oct 2025 08:45:07 +0000</pubDate>
				<guid isPermaLink="false">https://centralxl.com/product/br-x20ap3171/</guid>

					<description><![CDATA[<p>Calculates RMS values from currents and voltagesCalculates active, reactive and apparent powerPhasing detectionMeasures individual phases and calculates cumulative valuesOptional measurement of curren...</p>
<p>The post <a href="https://centralxl.com/product/br-x20ap3171/">B&amp;R X20AP3171</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Calculates RMS values from currents and voltagesCalculates active, reactive and apparent powerPhasing detectionMeasures individual phases and calculates cumulative valuesOptional measurement of current through the neutral conductorCalculates frequency and harmonics with high precisionNetTime timestamp: Moment when measured value groups are read</p>
<p>																	Power monitoringThese modules measure active, reactive and apparent power individually for each of the 3 phases as well as all of them collectively. The power consumption of each phase is also recorded individually and in total. In addition, the modules provide the RMS values for voltage and current on the 3 phases. When measuring the current, the value of the current through the neutral conductor can also be detected and monitored. Measurement of the mains frequency and the phase angle of the 3 phases (current and voltage) complete the power measurement data.Energy managementThe integrated functions on the modules map the immediate power requirements of the machine in detail as well as record its total power consumption. For the user, all relevant data is prepared and made available in the process image.The ability to measure currents and voltages up to the 31st harmonic enables higher precision recording of RMS values than is generally possible. This allows the modules to easily cope with irregular sine curves and makes them well-suited to renewable energy applications. In these types of applications, for example, being able to accurately measure the frequency at a resolution of  0.01 Hz between 45 and 65 Hz is a great advantage. In general, the modules are suitable for use with 1-phase, 2-phase or 3-phase networks.NetTime timestamp of readout momentsFor many applications, not only the measured value is important, but also the exact moment when a group of measured values is read out. The module is equipped with a NetTime timestamp function for this that supplies a timestamp for the recorded position and trigger time with microsecond accuracy.The timestamp function is based on synchronized timers. If a timestamp event occurs, the module immediately saves the current NetTime. After the respective data is transferred to the CPU, including this precise moment, the CPU can then evaluate the data using its own NetTime (or system time), if necessary.</p>
<p>The post <a href="https://centralxl.com/product/br-x20ap3171/">B&amp;R X20AP3171</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://centralxl.com/product/br-x20ap3171/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>B&#038;R X20AP3161</title>
		<link>https://centralxl.com/product/br-x20ap3161/</link>
					<comments>https://centralxl.com/product/br-x20ap3161/#respond</comments>
		
		<dc:creator><![CDATA[sales@partnerplc.com]]></dc:creator>
		<pubDate>Fri, 31 Oct 2025 08:45:06 +0000</pubDate>
				<guid isPermaLink="false">https://centralxl.com/product/br-x20ap3161/</guid>

					<description><![CDATA[<p>Calculates RMS values from currents and voltagesCalculates active, reactive and apparent powerPhasing detectionMeasures individual phases and calculates cumulative valuesOptional measurement of curren...</p>
<p>The post <a href="https://centralxl.com/product/br-x20ap3161/">B&amp;R X20AP3161</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Calculates RMS values from currents and voltagesCalculates active, reactive and apparent powerPhasing detectionMeasures individual phases and calculates cumulative valuesOptional measurement of current through the neutral conductorCalculates frequency and harmonics with high precisionNetTime timestamp: Moment when measured value groups are read</p>
<p>																	Power monitoringThese modules measure active, reactive and apparent power individually for each of the 3 phases as well as all of them collectively. The power consumption of each phase is also recorded individually and in total. In addition, the modules provide the RMS values for voltage and current on the 3 phases. When measuring the current, the value of the current through the neutral conductor can also be detected and monitored. Measurement of the mains frequency and the phase angle of the 3 phases (current and voltage) complete the power measurement data.Energy managementThe integrated functions on the modules map the immediate power requirements of the machine in detail as well as record its total power consumption. For the user, all relevant data is prepared and made available in the process image.The ability to measure currents and voltages up to the 31st harmonic enables higher precision recording of RMS values than is generally possible. This allows the modules to easily cope with irregular sine curves and makes them well-suited to renewable energy applications. In these types of applications, for example, being able to accurately measure the frequency at a resolution of  0.01 Hz between 45 and 65 Hz is a great advantage. In general, the modules are suitable for use with 1-phase, 2-phase or 3-phase networks.NetTime timestamp of readout momentsFor many applications, not only the measured value is important, but also the exact moment when a group of measured values is read out. The module is equipped with a NetTime timestamp function for this that supplies a timestamp for the recorded position and trigger time with microsecond accuracy.The timestamp function is based on synchronized timers. If a timestamp event occurs, the module immediately saves the current NetTime. After the respective data is transferred to the CPU, including this precise moment, the CPU can then evaluate the data using its own NetTime (or system time), if necessary.</p>
<p>The post <a href="https://centralxl.com/product/br-x20ap3161/">B&amp;R X20AP3161</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://centralxl.com/product/br-x20ap3161/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>B&#038;R X20AP3132</title>
		<link>https://centralxl.com/product/br-x20ap3132/</link>
					<comments>https://centralxl.com/product/br-x20ap3132/#respond</comments>
		
		<dc:creator><![CDATA[sales@partnerplc.com]]></dc:creator>
		<pubDate>Fri, 31 Oct 2025 08:45:04 +0000</pubDate>
				<guid isPermaLink="false">https://centralxl.com/product/br-x20ap3132/</guid>

					<description><![CDATA[<p>Calculates RMS values from currents and voltagesCalculates active, reactive and apparent powerPhasing detectionMeasures individual phases and calculates cumulative valuesOptional measurement of curren...</p>
<p>The post <a href="https://centralxl.com/product/br-x20ap3132/">B&amp;R X20AP3132</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Calculates RMS values from currents and voltagesCalculates active, reactive and apparent powerPhasing detectionMeasures individual phases and calculates cumulative valuesOptional measurement of current through the neutral conductorCalculates frequency and harmonics with high precisionNetTime timestamp: Moment when measured value groups are read</p>
<p>																	Power monitoringThese modules measure active, reactive and apparent power individually for each of the 3 phases as well as all of them collectively. The power consumption of each phase is also recorded individually and in total. In addition, the modules provide the RMS values for voltage and current on the 3 phases. When measuring the current, the value of the current through the neutral conductor can also be detected and monitored. Measurement of the mains frequency and the phase angle of the 3 phases (current and voltage) complete the power measurement data.Energy managementThe integrated functions on the modules map the immediate power requirements of the machine in detail as well as record its total power consumption. For the user, all relevant data is prepared and made available in the process image.The ability to measure currents and voltages up to the 31st harmonic enables higher precision recording of RMS values than is generally possible. This allows the modules to easily cope with irregular sine curves and makes them well-suited to renewable energy applications. In these types of applications, for example, being able to accurately measure the frequency at a resolution of  0.01 Hz between 45 and 65 Hz is a great advantage. In general, the modules are suitable for use with 1-phase, 2-phase or 3-phase networks.NetTime timestamp of readout momentsFor many applications, not only the measured value is important, but also the exact moment when a group of measured values is read out. The module is equipped with a NetTime timestamp function for this that supplies a timestamp for the recorded position and trigger time with microsecond accuracy.The timestamp function is based on synchronized timers. If a timestamp event occurs, the module immediately saves the current NetTime. After the respective data is transferred to the CPU, including this precise moment, the CPU can then evaluate the data using its own NetTime (or system time), if necessary.</p>
<p>The post <a href="https://centralxl.com/product/br-x20ap3132/">B&amp;R X20AP3132</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://centralxl.com/product/br-x20ap3132/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>B&#038;R X20AP3131</title>
		<link>https://centralxl.com/product/br-x20ap3131/</link>
					<comments>https://centralxl.com/product/br-x20ap3131/#respond</comments>
		
		<dc:creator><![CDATA[sales@partnerplc.com]]></dc:creator>
		<pubDate>Fri, 31 Oct 2025 08:45:03 +0000</pubDate>
				<guid isPermaLink="false">https://centralxl.com/product/br-x20ap3131/</guid>

					<description><![CDATA[<p>Calculates RMS values from currents and voltagesCalculates active, reactive and apparent powerPhasing detectionMeasures individual phases and calculates cumulative valuesOptional measurement of curren...</p>
<p>The post <a href="https://centralxl.com/product/br-x20ap3131/">B&amp;R X20AP3131</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Calculates RMS values from currents and voltagesCalculates active, reactive and apparent powerPhasing detectionMeasures individual phases and calculates cumulative valuesOptional measurement of current through the neutral conductorCalculates frequency and harmonics with high precisionNetTime timestamp: Moment when measured value groups are read</p>
<p>																	Power monitoringThese modules measure active, reactive and apparent power individually for each of the 3 phases as well as all of them collectively. The power consumption of each phase is also recorded individually and in total. In addition, the modules provide the RMS values for voltage and current on the 3 phases. When measuring the current, the value of the current through the neutral conductor can also be detected and monitored. Measurement of the mains frequency and the phase angle of the 3 phases (current and voltage) complete the power measurement data.Energy managementThe integrated functions on the modules map the immediate power requirements of the machine in detail as well as record its total power consumption. For the user, all relevant data is prepared and made available in the process image.The ability to measure currents and voltages up to the 31st harmonic enables higher precision recording of RMS values than is generally possible. This allows the modules to easily cope with irregular sine curves and makes them well-suited to renewable energy applications. In these types of applications, for example, being able to accurately measure the frequency at a resolution of  0.01 Hz between 45 and 65 Hz is a great advantage. In general, the modules are suitable for use with 1-phase, 2-phase or 3-phase networks.NetTime timestamp of readout momentsFor many applications, not only the measured value is important, but also the exact moment when a group of measured values is read out. The module is equipped with a NetTime timestamp function for this that supplies a timestamp for the recorded position and trigger time with microsecond accuracy.The timestamp function is based on synchronized timers. If a timestamp event occurs, the module immediately saves the current NetTime. After the respective data is transferred to the CPU, including this precise moment, the CPU can then evaluate the data using its own NetTime (or system time), if necessary.</p>
<p>The post <a href="https://centralxl.com/product/br-x20ap3131/">B&amp;R X20AP3131</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://centralxl.com/product/br-x20ap3131/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>B&#038;R X20AP3122</title>
		<link>https://centralxl.com/product/br-x20ap3122/</link>
					<comments>https://centralxl.com/product/br-x20ap3122/#respond</comments>
		
		<dc:creator><![CDATA[sales@partnerplc.com]]></dc:creator>
		<pubDate>Fri, 31 Oct 2025 08:45:01 +0000</pubDate>
				<guid isPermaLink="false">https://centralxl.com/product/br-x20ap3122/</guid>

					<description><![CDATA[<p>Calculates RMS values from currents and voltagesCalculates active, reactive and apparent powerPhasing detectionMeasures individual phases and calculates cumulative valuesOptional measurement of curren...</p>
<p>The post <a href="https://centralxl.com/product/br-x20ap3122/">B&amp;R X20AP3122</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Calculates RMS values from currents and voltagesCalculates active, reactive and apparent powerPhasing detectionMeasures individual phases and calculates cumulative valuesOptional measurement of current through the neutral conductorCalculates frequency and harmonics with high precisionNetTime timestamp: Moment when measured value groups are read</p>
<p>																	Power monitoringThese modules measure active, reactive and apparent power individually for each of the 3 phases as well as all of them collectively. The power consumption of each phase is also recorded individually and in total. In addition, the modules provide the RMS values for voltage and current on the 3 phases. When measuring the current, the value of the current through the neutral conductor can also be detected and monitored. Measurement of the mains frequency and the phase angle of the 3 phases (current and voltage) complete the power measurement data.Energy managementThe integrated functions on the modules map the immediate power requirements of the machine in detail as well as record its total power consumption. For the user, all relevant data is prepared and made available in the process image.The ability to measure currents and voltages up to the 31st harmonic enables higher precision recording of RMS values than is generally possible. This allows the modules to easily cope with irregular sine curves and makes them well-suited to renewable energy applications. In these types of applications, for example, being able to accurately measure the frequency at a resolution of  0.01 Hz between 45 and 65 Hz is a great advantage. In general, the modules are suitable for use with 1-phase, 2-phase or 3-phase networks.NetTime timestamp of readout momentsFor many applications, not only the measured value is important, but also the exact moment when a group of measured values is read out. The module is equipped with a NetTime timestamp function for this that supplies a timestamp for the recorded position and trigger time with microsecond accuracy.The timestamp function is based on synchronized timers. If a timestamp event occurs, the module immediately saves the current NetTime. After the respective data is transferred to the CPU, including this precise moment, the CPU can then evaluate the data using its own NetTime (or system time), if necessary.</p>
<p>The post <a href="https://centralxl.com/product/br-x20ap3122/">B&amp;R X20AP3122</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://centralxl.com/product/br-x20ap3122/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>B&#038;R X20AP3121</title>
		<link>https://centralxl.com/product/br-x20ap3121/</link>
					<comments>https://centralxl.com/product/br-x20ap3121/#respond</comments>
		
		<dc:creator><![CDATA[sales@partnerplc.com]]></dc:creator>
		<pubDate>Fri, 31 Oct 2025 08:44:56 +0000</pubDate>
				<guid isPermaLink="false">https://centralxl.com/product/br-x20ap3121/</guid>

					<description><![CDATA[<p>Calculates RMS values from currents and voltagesCalculates active, reactive and apparent powerPhasing detectionMeasures individual phases and calculates cumulative valuesOptional measurement of curren...</p>
<p>The post <a href="https://centralxl.com/product/br-x20ap3121/">B&amp;R X20AP3121</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Calculates RMS values from currents and voltagesCalculates active, reactive and apparent powerPhasing detectionMeasures individual phases and calculates cumulative valuesOptional measurement of current through the neutral conductorCalculates frequency and harmonics with high precisionNetTime timestamp: Moment when measured value groups are read</p>
<p>																	Power monitoringThese modules measure active, reactive and apparent power individually for each of the 3 phases as well as all of them collectively. The power consumption of each phase is also recorded individually and in total. In addition, the modules provide the RMS values for voltage and current on the 3 phases. When measuring the current, the value of the current through the neutral conductor can also be detected and monitored. Measurement of the mains frequency and the phase angle of the 3 phases (current and voltage) complete the power measurement data.Energy managementThe integrated functions on the modules map the immediate power requirements of the machine in detail as well as record its total power consumption. For the user, all relevant data is prepared and made available in the process image.The ability to measure currents and voltages up to the 31st harmonic enables higher precision recording of RMS values than is generally possible. This allows the modules to easily cope with irregular sine curves and makes them well-suited to renewable energy applications. In these types of applications, for example, being able to accurately measure the frequency at a resolution of  0.01 Hz between 45 and 65 Hz is a great advantage. In general, the modules are suitable for use with 1-phase, 2-phase or 3-phase networks.NetTime timestamp of readout momentsFor many applications, not only the measured value is important, but also the exact moment when a group of measured values is read out. The module is equipped with a NetTime timestamp function for this that supplies a timestamp for the recorded position and trigger time with microsecond accuracy.The timestamp function is based on synchronized timers. If a timestamp event occurs, the module immediately saves the current NetTime. After the respective data is transferred to the CPU, including this precise moment, the CPU can then evaluate the data using its own NetTime (or system time), if necessary.</p>
<p>The post <a href="https://centralxl.com/product/br-x20ap3121/">B&amp;R X20AP3121</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://centralxl.com/product/br-x20ap3121/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>B&#038;R X20AP3111</title>
		<link>https://centralxl.com/product/br-x20ap3111/</link>
					<comments>https://centralxl.com/product/br-x20ap3111/#respond</comments>
		
		<dc:creator><![CDATA[sales@partnerplc.com]]></dc:creator>
		<pubDate>Fri, 31 Oct 2025 08:44:55 +0000</pubDate>
				<guid isPermaLink="false">https://centralxl.com/product/br-x20ap3111/</guid>

					<description><![CDATA[<p>Calculates RMS values from currents and voltagesCalculates active, reactive and apparent powerPhasing detectionMeasures individual phases and calculates cumulative valuesOptional measurement of curren...</p>
<p>The post <a href="https://centralxl.com/product/br-x20ap3111/">B&amp;R X20AP3111</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Calculates RMS values from currents and voltagesCalculates active, reactive and apparent powerPhasing detectionMeasures individual phases and calculates cumulative valuesOptional measurement of current through the neutral conductorCalculates frequency and harmonics with high precisionNetTime timestamp: Moment when measured value groups are read</p>
<p>																	Power monitoringThese modules measure active, reactive and apparent power individually for each of the 3 phases as well as all of them collectively. The power consumption of each phase is also recorded individually and in total. In addition, the modules provide the RMS values for voltage and current on the 3 phases. When measuring the current, the value of the current through the neutral conductor can also be detected and monitored. Measurement of the mains frequency and the phase angle of the 3 phases (current and voltage) complete the power measurement data.Energy managementThe integrated functions on the modules map the immediate power requirements of the machine in detail as well as record its total power consumption. For the user, all relevant data is prepared and made available in the process image.The ability to measure currents and voltages up to the 31st harmonic enables higher precision recording of RMS values than is generally possible. This allows the modules to easily cope with irregular sine curves and makes them well-suited to renewable energy applications. In these types of applications, for example, being able to accurately measure the frequency at a resolution of  0.01 Hz between 45 and 65 Hz is a great advantage. In general, the modules are suitable for use with 1-phase, 2-phase or 3-phase networks.NetTime timestamp of readout momentsFor many applications, not only the measured value is important, but also the exact moment when a group of measured values is read out. The module is equipped with a NetTime timestamp function for this that supplies a timestamp for the recorded position and trigger time with microsecond accuracy.The timestamp function is based on synchronized timers. If a timestamp event occurs, the module immediately saves the current NetTime. After the respective data is transferred to the CPU, including this precise moment, the CPU can then evaluate the data using its own NetTime (or system time), if necessary.</p>
<p>The post <a href="https://centralxl.com/product/br-x20ap3111/">B&amp;R X20AP3111</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://centralxl.com/product/br-x20ap3111/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>B&#038;R X20AIB744</title>
		<link>https://centralxl.com/product/br-x20aib744/</link>
					<comments>https://centralxl.com/product/br-x20aib744/#respond</comments>
		
		<dc:creator><![CDATA[sales@partnerplc.com]]></dc:creator>
		<pubDate>Fri, 31 Oct 2025 08:44:36 +0000</pubDate>
				<guid isPermaLink="false">https://centralxl.com/product/br-x20aib744/</guid>

					<description><![CDATA[<p>4 full-bridge strain gauge inputs5 kHz data output rate for all 4 channelsIndependently configurable strain gauge factor and filter level for each of the 4 channels...</p>
<p>The post <a href="https://centralxl.com/product/br-x20aib744/">B&amp;R X20AIB744</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>4 full-bridge strain gauge inputs5 kHz data output rate for all 4 channelsIndependently configurable strain gauge factor and filter level for each of the 4 channels</p>
<p>																	This module works with 4-wire strain gauge load cells. The concept applied by the module requires compensation in the measurement system. This compensation eliminates the absolute uncertainty in the measurement circuit, such as component tolerances, effective bridge voltage or zero offset. The measurement precision refers to the absolute (compensated) value, which will only change as a result of changes in the operating temperature.</p>
<p>The post <a href="https://centralxl.com/product/br-x20aib744/">B&amp;R X20AIB744</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://centralxl.com/product/br-x20aib744/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>B&#038;R X20AIA744</title>
		<link>https://centralxl.com/product/br-x20aia744/</link>
					<comments>https://centralxl.com/product/br-x20aia744/#respond</comments>
		
		<dc:creator><![CDATA[sales@partnerplc.com]]></dc:creator>
		<pubDate>Fri, 31 Oct 2025 08:44:35 +0000</pubDate>
				<guid isPermaLink="false">https://centralxl.com/product/br-x20aia744/</guid>

					<description><![CDATA[<p>2 full-bridge strain gauge inputs5 kHz data output rate for both channelsIndependently configurable strain gauge factor and filter level for each of the 2 channels...</p>
<p>The post <a href="https://centralxl.com/product/br-x20aia744/">B&amp;R X20AIA744</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>2 full-bridge strain gauge inputs5 kHz data output rate for both channelsIndependently configurable strain gauge factor and filter level for each of the 2 channels</p>
<p>																	This module works with 4-wire strain gauge load cells. The concept applied by the module requires compensation in the measurement system. This compensation eliminates the absolute uncertainty in the measurement circuit, such as component tolerances, effective bridge voltage or zero offset. The measurement precision refers to the absolute (compensated) value, which will only change as a result of changes in the operating temperature.</p>
<p>The post <a href="https://centralxl.com/product/br-x20aia744/">B&amp;R X20AIA744</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://centralxl.com/product/br-x20aia744/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>B&#038;R X20AI8321</title>
		<link>https://centralxl.com/product/br-x20ai8321/</link>
					<comments>https://centralxl.com/product/br-x20ai8321/#respond</comments>
		
		<dc:creator><![CDATA[sales@partnerplc.com]]></dc:creator>
		<pubDate>Fri, 31 Oct 2025 08:44:34 +0000</pubDate>
				<guid isPermaLink="false">https://centralxl.com/product/br-x20ai8321/</guid>

					<description><![CDATA[<p>8 analog inputs, 0 to 20 mA or 4 to 20 mA12-bit digital converter resolution</p>
<p>																	The module is equipped with 8 inputs with 12-bit digital converter resolution....</p>
<p>The post <a href="https://centralxl.com/product/br-x20ai8321/">B&amp;R X20AI8321</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>8 analog inputs, 0 to 20 mA or 4 to 20 mA12-bit digital converter resolution</p>
<p>																	The module is equipped with 8 inputs with 12-bit digital converter resolution. It is possible to select between the two current ranges 0 to 20 mA and 4 to 20 mA.</p>
<p>The post <a href="https://centralxl.com/product/br-x20ai8321/">B&amp;R X20AI8321</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://centralxl.com/product/br-x20ai8321/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
