<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Float Switches Archives - CentralXL | Industrial Marketplace</title>
	<atom:link href="https://centralxl.com/product-category/industrial-sensors/level-measurement-industrial-sensors/float-switches/feed/" rel="self" type="application/rss+xml" />
	<link>https://centralxl.com/product-category/industrial-sensors/level-measurement-industrial-sensors/float-switches/</link>
	<description>The Marketplace for Industrial Supply &#38; Demand</description>
	<lastBuildDate>Tue, 20 Jan 2026 13:30:29 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://centralxl.com/wp-content/uploads/2025/10/cropped-centralxl-white-32x32.png</url>
	<title>Float Switches Archives - CentralXL | Industrial Marketplace</title>
	<link>https://centralxl.com/product-category/industrial-sensors/level-measurement-industrial-sensors/float-switches/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Pepperl Fuchs LFL2-CK-U-PUR5-EMS</title>
		<link>https://centralxl.com/product/pepperl-fuchs-lfl2-ck-u-pur5-ems/</link>
					<comments>https://centralxl.com/product/pepperl-fuchs-lfl2-ck-u-pur5-ems/#respond</comments>
		
		<dc:creator><![CDATA[sales@partnerplc.com]]></dc:creator>
		<pubDate>Tue, 20 Jan 2026 13:30:29 +0000</pubDate>
				<guid isPermaLink="false">https://centralxl.com/product/pepperl-fuchs-lfl2-ck-u-pur5-ems/</guid>

					<description><![CDATA[<p>Float Switch. Switch element: microswitch, <b>mercury-free</b>, Limit value detection for fluids, Sleeve design: small diameter, mounting through G1 tap hole possible. Series: LFL2-**-U. Construction...</p>
<p>The post <a href="https://centralxl.com/product/pepperl-fuchs-lfl2-ck-u-pur5-ems/">Pepperl Fuchs LFL2-CK-U-PUR5-EMS</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Float Switch. Switch element: microswitch, mercury-free, Limit value detection for fluids, Sleeve design: small diameter, mounting through G1 tap hole possible. Series: LFL2-**-U. Construction type: sleeve design. Contact loading: 250 V AC/3 A; 150 V DC/0.25 A resistive load; 60 V DC/1 A resistive load. Rated insulation voltage: 300 V. Pulse withstand voltage: 4 kV. Electrical life: ≥ 5 x 104 switching cycles. Low voltage: . Directive 2014/35/EUEN 60947-5-1:2004 + Cor.:2005 + A1:2009: . Directive 2014/35/EU: EN 60947-5-1:2004 + Cor.:2005 + A1:2009. Degree of protection: IEC 60529:2001. Description: microswitch with switching ball, change-over contact. Equipment architecture: This device may be used with any sequential circuit, as long as the circuit can support the electrical circuit values of the switching elements.. CCC approval: Certified by China Compulsory Certification (CCC). Installation conditions: . Installation instructionsrange of application and minimum length between mounting and float:≥ 100 mm (4 inch), preferred for fuels, heating oils, oily fluidsmounting:- The float switch is mounted either from sidewards through a cable gland ≥ G1A into the vessel or- by means of a counter weight or rods (e. g. float switch combination) from the top.The pivot of the cable should always be horizontal.: . Installation instructions: range of application and minimum length between mounting and float:≥ 100 mm (4 inch), preferred for fuels, heating oils, oily fluidsmounting:- The float switch is mounted either from sidewards through a cable gland ≥ G1A into the vessel or- by means of a counter weight or rods (e. g. float switch combination) from the top.The pivot of the cable should always be horizontal.. Process conditions: . Process pressure (static pressure)≤ 3 bar (43.5 psi) at 20 °C (68 °F)Density≥ 0.8 g/cm3: . Process pressure (static pressure): ≤ 3 bar (43.5 psi) at 20 °C (68 °F). Density: ≥ 0.8 g/cm3. Ambient temperature: 5 &#8230; 70 °C (41 &#8230; 158 °F). Storage temperature: -25 &#8230; 70 °C (-13 &#8230; 158 °F). Altitude: ≤ 2000 m above MSL. Degree of protection: IP68. Cable: . LengthL5 m: L. Length: 5 m. Material: float: PP (Polypropylene)cable: PUR, highly flexible (3 x 0.50 mm2). Switching point: switch angle, measured against the horizontal:- upper switch point 25° ±10°- lower switch point 6° ±6°. Supplementary information: Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.</p>
<p>The post <a href="https://centralxl.com/product/pepperl-fuchs-lfl2-ck-u-pur5-ems/">Pepperl Fuchs LFL2-CK-U-PUR5-EMS</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://centralxl.com/product/pepperl-fuchs-lfl2-ck-u-pur5-ems/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Pepperl Fuchs LFL2-BK-U-PUR5-EMS</title>
		<link>https://centralxl.com/product/pepperl-fuchs-lfl2-bk-u-pur5-ems/</link>
					<comments>https://centralxl.com/product/pepperl-fuchs-lfl2-bk-u-pur5-ems/#respond</comments>
		
		<dc:creator><![CDATA[sales@partnerplc.com]]></dc:creator>
		<pubDate>Tue, 20 Jan 2026 13:30:28 +0000</pubDate>
				<guid isPermaLink="false">https://centralxl.com/product/pepperl-fuchs-lfl2-bk-u-pur5-ems/</guid>

					<description><![CDATA[<p>Float Switch. Switch element: microswitch, <b>mercury-free</b>, Limit value detection for fluids, Ball design: high buoyancy. Series: LFL2-**-U. Construction type: ball design. Contact loading: 250 V...</p>
<p>The post <a href="https://centralxl.com/product/pepperl-fuchs-lfl2-bk-u-pur5-ems/">Pepperl Fuchs LFL2-BK-U-PUR5-EMS</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Float Switch. Switch element: microswitch, mercury-free, Limit value detection for fluids, Ball design: high buoyancy. Series: LFL2-**-U. Construction type: ball design. Contact loading: 250 V AC/3 A; 150 V DC/0.25 A resistive load; 60 V DC/1 A resistive load. Rated insulation voltage: 300 V. Pulse withstand voltage: 4 kV. Electrical life: ≥ 5 x 104 switching cycles. Low voltage: . Directive 2014/35/EUEN 60947-5-1:2004 + Cor.:2005 + A1:2009: . Directive 2014/35/EU: EN 60947-5-1:2004 + Cor.:2005 + A1:2009. Degree of protection: IEC 60529:2001. Description: microswitch with switching ball, change-over contact. Equipment architecture: This device may be used with any sequential circuit, as long as the circuit can support the electrical circuit values of the switching elements.. CCC approval: Certified by China Compulsory Certification (CCC). Installation conditions: . Installation instructionsrange of application and minimum length between mounting and float:≥ 100 mm (4 inch), preferred for fuels, heating oils, oily fluidsmounting:The float switch is mounted by means of a counter weight or rods (e. g. float switch combination) from the top.The pivot of the cable should always be horizontal.: . Installation instructions: range of application and minimum length between mounting and float:≥ 100 mm (4 inch), preferred for fuels, heating oils, oily fluidsmounting:The float switch is mounted by means of a counter weight or rods (e. g. float switch combination) from the top.The pivot of the cable should always be horizontal.. Process conditions: . Process pressure (static pressure)≤ 2 bar (29 psi) at 20 °C (68 °F)Density≥ 0.6 g/cm3: . Process pressure (static pressure): ≤ 2 bar (29 psi) at 20 °C (68 °F). Density: ≥ 0.6 g/cm3. Ambient temperature: 5 &#8230; 70 °C (41 &#8230; 158 °F). Storage temperature: -25 &#8230; 70 °C (-13 &#8230; 158 °F). Altitude: ≤ 2000 m above MSL. Degree of protection: IP68. Cable: . LengthL5 m: L. Length: 5 m. Material: float: PP (Polypropylene)cable: PUR, highly flexible (3 x 0.50 mm2). Switching point: switch angle, measured against the horizontal:- upper switch point 25° ±10°- lower switch point 6° ±6°. Supplementary information: Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.</p>
<p>The post <a href="https://centralxl.com/product/pepperl-fuchs-lfl2-bk-u-pur5-ems/">Pepperl Fuchs LFL2-BK-U-PUR5-EMS</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://centralxl.com/product/pepperl-fuchs-lfl2-bk-u-pur5-ems/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
