<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Level Measurement Archives - CentralXL | Industrial Marketplace</title>
	<atom:link href="https://centralxl.com/product-category/industrial-sensors/level-measurement-industrial-sensors/feed/" rel="self" type="application/rss+xml" />
	<link>https://centralxl.com/product-category/industrial-sensors/level-measurement-industrial-sensors/</link>
	<description>The Marketplace for Industrial Supply &#38; Demand</description>
	<lastBuildDate>Tue, 20 Jan 2026 13:30:51 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://centralxl.com/wp-content/uploads/2025/10/cropped-centralxl-white-32x32.png</url>
	<title>Level Measurement Archives - CentralXL | Industrial Marketplace</title>
	<link>https://centralxl.com/product-category/industrial-sensors/level-measurement-industrial-sensors/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Pepperl Fuchs LVL-B1</title>
		<link>https://centralxl.com/product/pepperl-fuchs-lvl-b1/</link>
					<comments>https://centralxl.com/product/pepperl-fuchs-lvl-b1/#respond</comments>
		
		<dc:creator><![CDATA[sales@partnerplc.com]]></dc:creator>
		<pubDate>Tue, 20 Jan 2026 13:30:51 +0000</pubDate>
				<guid isPermaLink="false">https://centralxl.com/product/pepperl-fuchs-lvl-b1/</guid>

					<description><![CDATA[<p>Vibration Limit Switch. Limit switch for bulk solids, Compact device, No calibration: easy commissioning (plug and play), Insensitive to build-up: maintenance-free operation, No mechanically moving pa...</p>
<p>The post <a href="https://centralxl.com/product/pepperl-fuchs-lvl-b1/">Pepperl Fuchs LVL-B1</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Vibration Limit Switch. Limit switch for bulk solids, Compact device, No calibration: easy commissioning (plug and play), Insensitive to build-up: maintenance-free operation, No mechanically moving parts: no wear, long operating life, Sensor material stainless steel: hardly any abrasion even with building materials, Insensitive to external vibration and flow noises. Measuring method: A piezoelectric drive excites the vibrating rod of the device to its resonance frequency. If medium covers the vibrating rod, the rod&#8217;s vibrating amplitude changes (the vibration is damped). The electronics of the device compare the actual amplitude with a target value and indicates whether the vibrating rod is vibrating freely or whether it is covered by medium.. Equipment architecture: The measuring system consists of:- the device with electronic insert- a supply point- the connected control systems, switching units, signalling systems (e. g. lamps, horns, PCS, PLC, etc.). Construction type: compact device. Operating mode: MAX = maximum safety:The device switches if the probe is covered or if the supply voltage is disconnected in a safety-oriented manner (signal on alarm).example application: overspill protectionMIN = minimum safety:The device switches if the probe is uncovered or if the supply voltage is disconnected in a safetyoriented manner (signal on alarm).example application: dry-running protection. Series: Vibracon LVL-B1. Rated voltage: electronic insert FEM22 (E5): 10 &#8230; 45 V DCelectronic insert FEM24 (WA): 19 &#8230; 253 V AC, 50/60 Hz or 19 &#8230; 55 V DC. Ripple: electronic insert FEM22 (E5): max. 5 V, 0 &#8230; 400 Hz. Current consumption: electronic insert FEM22 (E5): max. 18 mA. Power consumption: electronic insert FEM22 (E5): max. 0.81 Welectronic insert FEM 24 (WA): max. 1.3 W. Reverse polarity protection: separation voltage 2.2 kV. Surge protection: electronic insert FEM22 (E5) : overvoltage category III. Input signal: probe covered &#8211; small amplitudeprobe not covered &#8211; large amplitude. Measured variable: level (according to the mounting location and the overall length). Measuring range: The measuring range depends on the mounting location of the device. Load: electronic insert FEM22 (E5):- load switched via transistor and separate PNP connection- load current: max. 45 V (cyclical overload and short-circuit protection), continuous max. 350 mA- residual current: &lt; 100 µA (for blocked transistor)- capacitive load: max. 0.5 µF for 45 V, max. 1.0 µF for 24 V- residual voltage:  0.7- version DC: I max. 6 A to 30 V, I max. 0.2 A to 125 V- the following applies when connecting a functional extra-low voltage circuit with double insulation as per IEC 1010: sum of voltages of relay output and power supply max. 300 V. Switch-on delay: correct switching after max. 3 s. Output signal: digital. Signal on alarm: electronic insert FEM22 (E5): output signal on power failure or in the event of device failure &#8211; &lt; 100 µAelectronic insert FEM24 (WA): output signal in event of power failure &#8211; relay de-energised. Input/power supply: electronic insert FEM22 (E5). Input/Other circuits: electronic insert FEM24 (WA). Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2006 , EN 61326-2-3:2006: . Directive 2014/30/EU: EN 61326-1:2006 , EN 61326-2-3:2006. Low voltage: . Directive 2014/35/EUelectronic insert FEM24 (WA) : EN 61010-1:2010: . Directive 2014/35/EU: electronic insert FEM24 (WA) : EN 61010-1:2010. Electromagnetic compatibility: NE 21. Degree of protection: IEC 60529:2001. Vibration resistance: EN 60068-2-27. Climate class: EN 60068, part 2-38, fig. 2a. Measuring frequency: 700 &#8230; 800 Hz. Switching time: when covering the sensor approx. 0.5 s, when uncovering the sensor approx. 1.0 s. Installation conditions: . Installation positionsee section mounting position: . Installation position: see section mounting position. Process conditions: . Process temperature-40 &#8230; 150 °C (-40 &#8230; 302 °F)Medium pressure limits-1 &#8230; 25 bar max. working pressure 25 bar, burst pressure 100 barThermal shock resistancemax. 120 KState of aggregationsolidsSolid contents≤ ∅25 mmBulk density≥ 200 g/l, not fluidised: . Process temperature: -40 &#8230; 150 °C (-40 &#8230; 302 °F). Medium pressure limits: -1 &#8230; 25 bar max. working pressure 25 bar, burst pressure 100 bar. Thermal shock resistance: max. 120 K. State of aggregation: solids. Solid contents: ≤ ∅25 mm. Bulk density: ≥ 200 g/l, not fluidised. Ambient temperature: -40 &#8230; 70 °C (-40 &#8230; 158 °F). Storage temperature: -40 &#8230; 85 °C (-40 &#8230; 185 °F). Degree of protection: IP66 / IP67, NEMA 4X. Connection: gland M20thread G1/2, NPT1/2. Material: F16 housing: PTB-FR, cover with transparent glass made of PA12, EPDM cover sealF18 housing: aluminum EN-AC-AlSi10Mg, plastic coatedcover seal: EPDMprocess connections, sensor: stainless steel 1.4435/316L. Mass: device with F16 housing, electronic insert FEM24 (WA) and R1 thread: approx. 1.0 kg. Dimensions: max. ∅85 mm (3.3 inch), length 372 mm (14.6 inch). Process connection: thread R1, R1-1/2 acc. to DIN 2999thread 1-1/4 &#8211; 11-1/2 NPT, 1-1/2 &#8211; 11-1/2 NPT acc. to ANSI B 1.20.1. EU-type examination certificate: see instruction manuals. IECEx approval: see instruction manuals. Supplementary documentation: technical information (TI) manuals, brief instructions (BA, KA) instruction manuals. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.</p>
<p>The post <a href="https://centralxl.com/product/pepperl-fuchs-lvl-b1/">Pepperl Fuchs LVL-B1</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://centralxl.com/product/pepperl-fuchs-lvl-b1/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Pepperl Fuchs LFL2-CK-U-PUR5-EMS</title>
		<link>https://centralxl.com/product/pepperl-fuchs-lfl2-ck-u-pur5-ems/</link>
					<comments>https://centralxl.com/product/pepperl-fuchs-lfl2-ck-u-pur5-ems/#respond</comments>
		
		<dc:creator><![CDATA[sales@partnerplc.com]]></dc:creator>
		<pubDate>Tue, 20 Jan 2026 13:30:29 +0000</pubDate>
				<guid isPermaLink="false">https://centralxl.com/product/pepperl-fuchs-lfl2-ck-u-pur5-ems/</guid>

					<description><![CDATA[<p>Float Switch. Switch element: microswitch, <b>mercury-free</b>, Limit value detection for fluids, Sleeve design: small diameter, mounting through G1 tap hole possible. Series: LFL2-**-U. Construction...</p>
<p>The post <a href="https://centralxl.com/product/pepperl-fuchs-lfl2-ck-u-pur5-ems/">Pepperl Fuchs LFL2-CK-U-PUR5-EMS</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Float Switch. Switch element: microswitch, mercury-free, Limit value detection for fluids, Sleeve design: small diameter, mounting through G1 tap hole possible. Series: LFL2-**-U. Construction type: sleeve design. Contact loading: 250 V AC/3 A; 150 V DC/0.25 A resistive load; 60 V DC/1 A resistive load. Rated insulation voltage: 300 V. Pulse withstand voltage: 4 kV. Electrical life: ≥ 5 x 104 switching cycles. Low voltage: . Directive 2014/35/EUEN 60947-5-1:2004 + Cor.:2005 + A1:2009: . Directive 2014/35/EU: EN 60947-5-1:2004 + Cor.:2005 + A1:2009. Degree of protection: IEC 60529:2001. Description: microswitch with switching ball, change-over contact. Equipment architecture: This device may be used with any sequential circuit, as long as the circuit can support the electrical circuit values of the switching elements.. CCC approval: Certified by China Compulsory Certification (CCC). Installation conditions: . Installation instructionsrange of application and minimum length between mounting and float:≥ 100 mm (4 inch), preferred for fuels, heating oils, oily fluidsmounting:- The float switch is mounted either from sidewards through a cable gland ≥ G1A into the vessel or- by means of a counter weight or rods (e. g. float switch combination) from the top.The pivot of the cable should always be horizontal.: . Installation instructions: range of application and minimum length between mounting and float:≥ 100 mm (4 inch), preferred for fuels, heating oils, oily fluidsmounting:- The float switch is mounted either from sidewards through a cable gland ≥ G1A into the vessel or- by means of a counter weight or rods (e. g. float switch combination) from the top.The pivot of the cable should always be horizontal.. Process conditions: . Process pressure (static pressure)≤ 3 bar (43.5 psi) at 20 °C (68 °F)Density≥ 0.8 g/cm3: . Process pressure (static pressure): ≤ 3 bar (43.5 psi) at 20 °C (68 °F). Density: ≥ 0.8 g/cm3. Ambient temperature: 5 &#8230; 70 °C (41 &#8230; 158 °F). Storage temperature: -25 &#8230; 70 °C (-13 &#8230; 158 °F). Altitude: ≤ 2000 m above MSL. Degree of protection: IP68. Cable: . LengthL5 m: L. Length: 5 m. Material: float: PP (Polypropylene)cable: PUR, highly flexible (3 x 0.50 mm2). Switching point: switch angle, measured against the horizontal:- upper switch point 25° ±10°- lower switch point 6° ±6°. Supplementary information: Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.</p>
<p>The post <a href="https://centralxl.com/product/pepperl-fuchs-lfl2-ck-u-pur5-ems/">Pepperl Fuchs LFL2-CK-U-PUR5-EMS</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://centralxl.com/product/pepperl-fuchs-lfl2-ck-u-pur5-ems/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Pepperl Fuchs LFL2-BK-U-PUR5-EMS</title>
		<link>https://centralxl.com/product/pepperl-fuchs-lfl2-bk-u-pur5-ems/</link>
					<comments>https://centralxl.com/product/pepperl-fuchs-lfl2-bk-u-pur5-ems/#respond</comments>
		
		<dc:creator><![CDATA[sales@partnerplc.com]]></dc:creator>
		<pubDate>Tue, 20 Jan 2026 13:30:28 +0000</pubDate>
				<guid isPermaLink="false">https://centralxl.com/product/pepperl-fuchs-lfl2-bk-u-pur5-ems/</guid>

					<description><![CDATA[<p>Float Switch. Switch element: microswitch, <b>mercury-free</b>, Limit value detection for fluids, Ball design: high buoyancy. Series: LFL2-**-U. Construction type: ball design. Contact loading: 250 V...</p>
<p>The post <a href="https://centralxl.com/product/pepperl-fuchs-lfl2-bk-u-pur5-ems/">Pepperl Fuchs LFL2-BK-U-PUR5-EMS</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Float Switch. Switch element: microswitch, mercury-free, Limit value detection for fluids, Ball design: high buoyancy. Series: LFL2-**-U. Construction type: ball design. Contact loading: 250 V AC/3 A; 150 V DC/0.25 A resistive load; 60 V DC/1 A resistive load. Rated insulation voltage: 300 V. Pulse withstand voltage: 4 kV. Electrical life: ≥ 5 x 104 switching cycles. Low voltage: . Directive 2014/35/EUEN 60947-5-1:2004 + Cor.:2005 + A1:2009: . Directive 2014/35/EU: EN 60947-5-1:2004 + Cor.:2005 + A1:2009. Degree of protection: IEC 60529:2001. Description: microswitch with switching ball, change-over contact. Equipment architecture: This device may be used with any sequential circuit, as long as the circuit can support the electrical circuit values of the switching elements.. CCC approval: Certified by China Compulsory Certification (CCC). Installation conditions: . Installation instructionsrange of application and minimum length between mounting and float:≥ 100 mm (4 inch), preferred for fuels, heating oils, oily fluidsmounting:The float switch is mounted by means of a counter weight or rods (e. g. float switch combination) from the top.The pivot of the cable should always be horizontal.: . Installation instructions: range of application and minimum length between mounting and float:≥ 100 mm (4 inch), preferred for fuels, heating oils, oily fluidsmounting:The float switch is mounted by means of a counter weight or rods (e. g. float switch combination) from the top.The pivot of the cable should always be horizontal.. Process conditions: . Process pressure (static pressure)≤ 2 bar (29 psi) at 20 °C (68 °F)Density≥ 0.6 g/cm3: . Process pressure (static pressure): ≤ 2 bar (29 psi) at 20 °C (68 °F). Density: ≥ 0.6 g/cm3. Ambient temperature: 5 &#8230; 70 °C (41 &#8230; 158 °F). Storage temperature: -25 &#8230; 70 °C (-13 &#8230; 158 °F). Altitude: ≤ 2000 m above MSL. Degree of protection: IP68. Cable: . LengthL5 m: L. Length: 5 m. Material: float: PP (Polypropylene)cable: PUR, highly flexible (3 x 0.50 mm2). Switching point: switch angle, measured against the horizontal:- upper switch point 25° ±10°- lower switch point 6° ±6°. Supplementary information: Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.</p>
<p>The post <a href="https://centralxl.com/product/pepperl-fuchs-lfl2-bk-u-pur5-ems/">Pepperl Fuchs LFL2-BK-U-PUR5-EMS</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://centralxl.com/product/pepperl-fuchs-lfl2-bk-u-pur5-ems/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
