<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>H-System (Termination Board Mounting) Archives - CentralXL | Industrial Marketplace</title>
	<atom:link href="https://centralxl.com/product-category/hazardous-area-products-and-solutions/intrinsic-safety-barriers/h-system-termination-board-mounting/feed/" rel="self" type="application/rss+xml" />
	<link>https://centralxl.com/product-category/hazardous-area-products-and-solutions/intrinsic-safety-barriers/h-system-termination-board-mounting/</link>
	<description>The Marketplace for Industrial Supply &#38; Demand</description>
	<lastBuildDate>Tue, 20 Jan 2026 13:27:38 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://centralxl.com/wp-content/uploads/2025/10/cropped-centralxl-white-32x32.png</url>
	<title>H-System (Termination Board Mounting) Archives - CentralXL | Industrial Marketplace</title>
	<link>https://centralxl.com/product-category/hazardous-area-products-and-solutions/intrinsic-safety-barriers/h-system-termination-board-mounting/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Pepperl Fuchs HiCTB32-HIM-RAS-SP-DI320X</title>
		<link>https://centralxl.com/product/pepperl-fuchs-hictb32-him-ras-sp-di320x/</link>
					<comments>https://centralxl.com/product/pepperl-fuchs-hictb32-him-ras-sp-di320x/#respond</comments>
		
		<dc:creator><![CDATA[sales@partnerplc.com]]></dc:creator>
		<pubDate>Tue, 20 Jan 2026 13:27:38 +0000</pubDate>
				<guid isPermaLink="false">https://centralxl.com/product/pepperl-fuchs-hictb32-him-ras-sp-di320x/</guid>

					<description><![CDATA[<p>Termination Board. System board for HIMA, HIMax, For 32-channel cards X-DI 32 01 or X-DI 32 04 (DI), For 32 modules, Recommended modules: HiC2821 (DI), HiC2841 (DI), 24 V DC supply, Hazardous area: sp...</p>
<p>The post <a href="https://centralxl.com/product/pepperl-fuchs-hictb32-him-ras-sp-di320x/">Pepperl Fuchs HiCTB32-HIM-RAS-SP-DI320X</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Termination Board. System board for HIMA, HIMax, For 32-channel cards X-DI 32 01 or X-DI 32 04 (DI), For 32 modules, Recommended modules: HiC2821 (DI), HiC2841 (DI), 24 V DC supply, Hazardous area: spring terminals, blue, Non-hazardous area: HIMA system connector, 96-pin, Non-hazardous area: spring terminals, black, Number of modules: 32, Signal type: Digital Input, Manufacturer: HIMA, Control system type: HIMax. Connection: XG2: terminals 1, 3 (+); 2, 4 (-). Nominal voltage: 24 V DC , in consideration of rated voltage of used isolators. Voltage drop: 0.9 V , voltage drop across the series diode on the termination board must be considered. Ripple: ≤ 10 %. Fusing: 4 A , in each case for 32 modules. Power dissipation: ≤ 500 mW , without modules. Reverse polarity protection: yes. Supply: Redundancy available. The supply for the isolators is decoupled, monitored and fused.. Connection: XG2: terminals 5, 6. Output type: volt-free contact. Switch behaviour: no fault: relay contact closed power supply fault: relay contact open module fault: relay contact open. Contact loading: 30 V DC, 1 A. Display elements: LED PWR1 (termination board power supply), green LEDLED PWR2 (termination board power supply), green LED LED FAULT (fault indication), red LED- LED lits: power supply fault- LED flashes: module fault LED Run, green LED- The HIMax I/O module is supplied with power and is connected to the Termination Board (FTA) via a system cable.LED Field, red LED- The HIMax I/O module detects faults in the connection between HIMax I/O module and Termination Board (FTA).. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013 (industrial locations): . Directive 2014/30/EU: EN 61326-1:2013 (industrial locations). Electromagnetic compatibility: NE 21:2017For further information see system description.. Degree of protection: IEC 60529:2001. Ambient temperature: -20 &#8230; 60 °C (-4 &#8230; 140 °F). Storage temperature: -40 &#8230; 85 °C (-40 &#8230; 185 °F). Degree of protection: IP20. Connection: . Field sideexplosion hazardous area: spring terminals , blueControl sidenon-explosion hazardous area: HIMA system connector, 96-pin and spring terminals , blackSupplypluggable spring terminals , blackFault outputpluggable spring terminals , black: . Field side: explosion hazardous area: spring terminals , blue. Control side: non-explosion hazardous area: HIMA system connector, 96-pin and spring terminals , black. Supply: pluggable spring terminals , black. Fault output: pluggable spring terminals , black. Core cross section: spring terminals: 0.25 &#8230; 1.5 mm2 (24 &#8230; 16 AWG). Material: housing: polycarbonate, 10 % glass fiber reinforced. Mass: approx. 1360 g. Dimensions: 432 x 200 x 163 mm (17 x 7.9 x 6.42 inch) (W x H x D) , depth including module assembly. Height200 mmWidth432 mmDepth163 mm: . Height: 200 mm. Width: 432 mm. Depth: 163 mm. Mounting: on 35 mm DIN mounting rail acc. to EN 60715:2001. EU-type examination certificate: CESI 06 ATEX 022. Marking II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I: . Marking: II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I. Non-hazardous area: . Maximum safe voltage250 V (Attention! Um is no rated voltage.): . Maximum safe voltage: 250 V (Attention! Um is no rated voltage.). Galvanic isolation: . Field circuit/control circuitsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V: . Field circuit/control circuit: safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 50303:2000: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 50303:2000. UL approval: E106378. Control drawing116-0327: . Control drawing: 116-0327. IECEx approval: . IECEx certificateIECEx CES 06.0003IECEx marking[Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Ma] I: . IECEx certificate: IECEx CES 06.0003. IECEx marking: [Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Ma] I. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.</p>
<p>The post <a href="https://centralxl.com/product/pepperl-fuchs-hictb32-him-ras-sp-di320x/">Pepperl Fuchs HiCTB32-HIM-RAS-SP-DI320X</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://centralxl.com/product/pepperl-fuchs-hictb32-him-ras-sp-di320x/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Pepperl Fuchs HiCTB32-HIM-RAC-SP-DI320X</title>
		<link>https://centralxl.com/product/pepperl-fuchs-hictb32-him-rac-sp-di320x/</link>
					<comments>https://centralxl.com/product/pepperl-fuchs-hictb32-him-rac-sp-di320x/#respond</comments>
		
		<dc:creator><![CDATA[sales@partnerplc.com]]></dc:creator>
		<pubDate>Tue, 20 Jan 2026 13:27:37 +0000</pubDate>
				<guid isPermaLink="false">https://centralxl.com/product/pepperl-fuchs-hictb32-him-rac-sp-di320x/</guid>

					<description><![CDATA[<p>Termination Board. System board for HIMA, HIMax, For 32-channel cards X-DI 32 01 or X-DI 32 04 (DI), For 32 modules, Recommended modules: HiC2441 (UIO), HiC2821 (DI), HiC2841 (DI), 24 V DC supply, Haz...</p>
<p>The post <a href="https://centralxl.com/product/pepperl-fuchs-hictb32-him-rac-sp-di320x/">Pepperl Fuchs HiCTB32-HIM-RAC-SP-DI320X</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Termination Board. System board for HIMA, HIMax, For 32-channel cards X-DI 32 01 or X-DI 32 04 (DI), For 32 modules, Recommended modules: HiC2441 (UIO), HiC2821 (DI), HiC2841 (DI), 24 V DC supply, Hazardous area: spring terminals, blue, Non-hazardous area: HIMA system connector, 96-pin, Number of modules: 32, Signal type: Digital Input, Manufacturer: HIMA, Control system type: HIMax. Connection: XG2: terminals 1, 3 (+); 2, 4 (-). Nominal voltage: 24 V DC , in consideration of rated voltage of used isolators. Voltage drop: 0.9 V , voltage drop across the series diode on the termination board must be considered. Ripple: ≤ 10 %. Fusing: 4 A , in each case for 32 modules. Power dissipation: ≤ 500 mW , without modules. Reverse polarity protection: yes. Supply: Redundancy available. The supply for the isolators is decoupled, monitored and fused.. Connection: XG2: terminals 5, 6. Output type: volt-free contact. Switch behaviour: no fault: relay contact closed power supply fault: relay contact open module fault: relay contact open. Contact loading: 30 V DC, 1 A. Display elements: LED PWR1 (termination board power supply), green LEDLED PWR2 (termination board power supply), green LED LED FAULT (fault indication), red LED- LED lits: power supply fault- LED flashes: module fault LED Run, green LED- The HIMax I/O module is supplied with power and is connected to the Termination Board (FTA) via a system cable.LED Field, red LED- The HIMax I/O module detects faults in the connection between HIMax I/O module and Termination Board (FTA).. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013 (industrial locations): . Directive 2014/30/EU: EN 61326-1:2013 (industrial locations). Electromagnetic compatibility: NE 21:2017For further information see system description.. Degree of protection: IEC 60529:2001. Ambient temperature: -20 &#8230; 60 °C (-4 &#8230; 140 °F). Storage temperature: -40 &#8230; 85 °C (-40 &#8230; 185 °F). Degree of protection: IP20. Connection: . Field sideexplosion hazardous area: spring terminals , blueControl sidenon-explosion hazardous area: HIMA system connector, 96-pinSupplypluggable spring terminals , blackFault outputpluggable spring terminals , black: . Field side: explosion hazardous area: spring terminals , blue. Control side: non-explosion hazardous area: HIMA system connector, 96-pin. Supply: pluggable spring terminals , black. Fault output: pluggable spring terminals , black. Core cross section: spring terminals: 0.25 &#8230; 1.5 mm2 (24 &#8230; 16 AWG). Material: housing: polycarbonate, 10 % glass fiber reinforced. Mass: approx. 1280 g. Dimensions: 432 x 200 x 163 mm (17 x 7.9 x 6.42 inch) (W x H x D) , depth including module assembly. Height200 mmWidth432 mmDepth163 mm: . Height: 200 mm. Width: 432 mm. Depth: 163 mm. Mounting: on 35 mm DIN mounting rail acc. to EN 60715:2001. EU-type examination certificate: CESI 06 ATEX 022. Marking II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I: . Marking: II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I. Non-hazardous area: . Maximum safe voltage250 V (Attention! Um is no rated voltage.): . Maximum safe voltage: 250 V (Attention! Um is no rated voltage.). Galvanic isolation: . Field circuit/control circuitsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V: . Field circuit/control circuit: safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 50303:2000: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 50303:2000. UL approval: E106378. Control drawing116-0327: . Control drawing: 116-0327. IECEx approval: . IECEx certificateIECEx CES 06.0003IECEx marking[Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Ma] I: . IECEx certificate: IECEx CES 06.0003. IECEx marking: [Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Ma] I. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.</p>
<p>The post <a href="https://centralxl.com/product/pepperl-fuchs-hictb32-him-rac-sp-di320x/">Pepperl Fuchs HiCTB32-HIM-RAC-SP-DI320X</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://centralxl.com/product/pepperl-fuchs-hictb32-him-rac-sp-di320x/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Pepperl Fuchs HiCTB32-HIM-RAS-SP-DI3202</title>
		<link>https://centralxl.com/product/pepperl-fuchs-hictb32-him-ras-sp-di3202/</link>
					<comments>https://centralxl.com/product/pepperl-fuchs-hictb32-him-ras-sp-di3202/#respond</comments>
		
		<dc:creator><![CDATA[sales@partnerplc.com]]></dc:creator>
		<pubDate>Tue, 20 Jan 2026 13:27:37 +0000</pubDate>
				<guid isPermaLink="false">https://centralxl.com/product/pepperl-fuchs-hictb32-him-ras-sp-di3202/</guid>

					<description><![CDATA[<p>Termination Board. System board for HIMA, HIMax, For 32-channel card X-DI 32 02 (DI), For 32 modules, Recommended modules: HiC2831 (DI), HiC2853 (DI), 24 V DC supply, Hazardous area: spring terminals,...</p>
<p>The post <a href="https://centralxl.com/product/pepperl-fuchs-hictb32-him-ras-sp-di3202/">Pepperl Fuchs HiCTB32-HIM-RAS-SP-DI3202</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Termination Board. System board for HIMA, HIMax, For 32-channel card X-DI 32 02 (DI), For 32 modules, Recommended modules: HiC2831 (DI), HiC2853 (DI), 24 V DC supply, Hazardous area: spring terminals, blue, Non-hazardous area: HIMA system connector, 96-pin, Non-hazardous area: spring terminals, black, Number of modules: 32, Signal type: Digital Input, Manufacturer: HIMA, Control system type: HIMax. Connection: XG2: terminals 1, 3 (+); 2, 4 (-). Nominal voltage: 24 V DC , in consideration of rated voltage of used isolators. Voltage drop: 0.9 V , voltage drop across the series diode on the termination board must be considered. Ripple: ≤ 10 %. Fusing: 4 A , in each case for 32 modules. Power dissipation: ≤ 500 mW , without modules. Reverse polarity protection: yes. Supply: Redundancy available. The supply for the isolators is decoupled, monitored and fused.. Connection: XG2: terminals 5, 6. Output type: volt-free contact. Switch behaviour: no fault: relay contact closed power supply fault: relay contact open module fault: relay contact open. Contact loading: 30 V DC, 1 A. Display elements: LED PWR1 (termination board power supply), green LEDLED PWR2 (termination board power supply), green LED LED FAULT (fault indication), red LED- LED lits: power supply fault- LED flashes: module fault LED Run, green LED- The HIMax I/O module is supplied with power and is connected to the Termination Board (FTA) via a system cable.LED Field, red LED- The HIMax I/O module detects faults in the connection between HIMax I/O module and Termination Board (FTA).. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013 (industrial locations): . Directive 2014/30/EU: EN 61326-1:2013 (industrial locations). Electromagnetic compatibility: NE 21:2017For further information see system description.. Degree of protection: IEC 60529:2001. Ambient temperature: -20 &#8230; 60 °C (-4 &#8230; 140 °F). Storage temperature: -40 &#8230; 85 °C (-40 &#8230; 185 °F). Degree of protection: IP20. Connection: . Field sideexplosion hazardous area: spring terminals , blueControl sidenon-explosion hazardous area: HIMA system connector, 96-pin and spring terminals , blackSupplypluggable spring terminals , blackFault outputpluggable spring terminals , black: . Field side: explosion hazardous area: spring terminals , blue. Control side: non-explosion hazardous area: HIMA system connector, 96-pin and spring terminals , black. Supply: pluggable spring terminals , black. Fault output: pluggable spring terminals , black. Core cross section: spring terminals: 0.25 &#8230; 1.5 mm2 (24 &#8230; 16 AWG). Material: housing: polycarbonate, 10 % glass fiber reinforced. Mass: approx. 1380 g. Dimensions: 432 x 200 x 163 mm (17 x 7.9 x 6.42 inch) (W x H x D) , depth including module assembly. Height200 mmWidth432 mmDepth163 mm: . Height: 200 mm. Width: 432 mm. Depth: 163 mm. Mounting: on 35 mm DIN mounting rail acc. to EN 60715:2001. EU-type examination certificate: CESI 06 ATEX 022. Marking II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I: . Marking: II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I. Non-hazardous area: . Maximum safe voltage250 V (Attention! Um is no rated voltage.): . Maximum safe voltage: 250 V (Attention! Um is no rated voltage.). Galvanic isolation: . Field circuit/control circuitsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V: . Field circuit/control circuit: safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 50303:2000: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 50303:2000. UL approval: E106378. Control drawing116-0327: . Control drawing: 116-0327. IECEx approval: . IECEx certificateIECEx CES 06.0003IECEx marking[Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Ma] I: . IECEx certificate: IECEx CES 06.0003. IECEx marking: [Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Ma] I. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.</p>
<p>The post <a href="https://centralxl.com/product/pepperl-fuchs-hictb32-him-ras-sp-di3202/">Pepperl Fuchs HiCTB32-HIM-RAS-SP-DI3202</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://centralxl.com/product/pepperl-fuchs-hictb32-him-ras-sp-di3202/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Pepperl Fuchs HiCTB32-HIM-RAC-SP-DI3202</title>
		<link>https://centralxl.com/product/pepperl-fuchs-hictb32-him-rac-sp-di3202/</link>
					<comments>https://centralxl.com/product/pepperl-fuchs-hictb32-him-rac-sp-di3202/#respond</comments>
		
		<dc:creator><![CDATA[sales@partnerplc.com]]></dc:creator>
		<pubDate>Tue, 20 Jan 2026 13:27:30 +0000</pubDate>
				<guid isPermaLink="false">https://centralxl.com/product/pepperl-fuchs-hictb32-him-rac-sp-di3202/</guid>

					<description><![CDATA[<p>Termination Board. System board for HIMA, HIMax, For 32-channel card X-DI 32 02 (DI), For 32 modules, Recommended modules: HiC2831 (DI), HiC2853 (DI), 24 V DC supply, Hazardous area: spring terminals,...</p>
<p>The post <a href="https://centralxl.com/product/pepperl-fuchs-hictb32-him-rac-sp-di3202/">Pepperl Fuchs HiCTB32-HIM-RAC-SP-DI3202</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Termination Board. System board for HIMA, HIMax, For 32-channel card X-DI 32 02 (DI), For 32 modules, Recommended modules: HiC2831 (DI), HiC2853 (DI), 24 V DC supply, Hazardous area: spring terminals, blue, Non-hazardous area: HIMA system connector, 96-pin, Number of modules: 32, Signal type: Digital Input, Manufacturer: HIMA, Control system type: HIMax. Connection: XG2: terminals 1, 3 (+); 2, 4 (-). Nominal voltage: 24 V DC , in consideration of rated voltage of used isolators. Voltage drop: 0.9 V , voltage drop across the series diode on the termination board must be considered. Ripple: ≤ 10 %. Fusing: 4 A , in each case for 32 modules. Power dissipation: ≤ 500 mW , without modules. Reverse polarity protection: yes. Supply: Redundancy available. The supply for the isolators is decoupled, monitored and fused.. Connection: XG2: terminals 5, 6. Output type: volt-free contact. Switch behaviour: no fault: relay contact closed power supply fault: relay contact open module fault: relay contact open. Contact loading: 30 V DC, 1 A. Display elements: LED PWR1 (termination board power supply), green LEDLED PWR2 (termination board power supply), green LED LED FAULT (fault indication), red LED- LED lits: power supply fault- LED flashes: module fault LED Run, green LED- The HIMax I/O module is supplied with power and is connected to the Termination Board (FTA) via a system cable.LED Field, red LED- The HIMax I/O module detects faults in the connection between HIMax I/O module and Termination Board (FTA).. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013 (industrial locations): . Directive 2014/30/EU: EN 61326-1:2013 (industrial locations). Electromagnetic compatibility: NE 21:2017For further information see system description.. Degree of protection: IEC 60529:2001. Ambient temperature: -20 &#8230; 60 °C (-4 &#8230; 140 °F). Storage temperature: -40 &#8230; 85 °C (-40 &#8230; 185 °F). Degree of protection: IP20. Connection: . Field sideexplosion hazardous area: spring terminals , blueControl sidenon-explosion hazardous area: HIMA system connector, 96-pinSupplypluggable spring terminals , blackFault outputpluggable spring terminals , black: . Field side: explosion hazardous area: spring terminals , blue. Control side: non-explosion hazardous area: HIMA system connector, 96-pin. Supply: pluggable spring terminals , black. Fault output: pluggable spring terminals , black. Core cross section: spring terminals: 0.25 &#8230; 1.5 mm2 (24 &#8230; 16 AWG). Material: housing: polycarbonate, 10 % glass fiber reinforced. Mass: approx. 1270 g. Dimensions: 432 x 200 x 163 mm (17 x 7.9 x 6.42 inch) (W x H x D) , depth including module assembly. Height200 mmWidth432 mmDepth163 mm: . Height: 200 mm. Width: 432 mm. Depth: 163 mm. Mounting: on 35 mm DIN mounting rail acc. to EN 60715:2001. EU-type examination certificate: CESI 06 ATEX 022. Marking II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I: . Marking: II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I. Non-hazardous area: . Maximum safe voltage250 V (Attention! Um is no rated voltage.): . Maximum safe voltage: 250 V (Attention! Um is no rated voltage.). Galvanic isolation: . Field circuit/control circuitsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V: . Field circuit/control circuit: safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 50303:2000: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 50303:2000. UL approval: E106378. Control drawing116-0327: . Control drawing: 116-0327. IECEx approval: . IECEx certificateIECEx CES 06.0003IECEx marking[Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Ma] I: . IECEx certificate: IECEx CES 06.0003. IECEx marking: [Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Ma] I. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.</p>
<p>The post <a href="https://centralxl.com/product/pepperl-fuchs-hictb32-him-rac-sp-di3202/">Pepperl Fuchs HiCTB32-HIM-RAC-SP-DI3202</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://centralxl.com/product/pepperl-fuchs-hictb32-him-rac-sp-di3202/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Pepperl Fuchs HiCTB16-HIM-RAC-SP-DI320X</title>
		<link>https://centralxl.com/product/pepperl-fuchs-hictb16-him-rac-sp-di320x/</link>
					<comments>https://centralxl.com/product/pepperl-fuchs-hictb16-him-rac-sp-di320x/#respond</comments>
		
		<dc:creator><![CDATA[sales@partnerplc.com]]></dc:creator>
		<pubDate>Tue, 20 Jan 2026 13:27:28 +0000</pubDate>
				<guid isPermaLink="false">https://centralxl.com/product/pepperl-fuchs-hictb16-him-rac-sp-di320x/</guid>

					<description><![CDATA[<p>Termination Board. System board for HIMA, HIMax, For 32-channel cards X-DI 32 01 or X-DI 32 04 (DI), For 16 modules, Recommended modules: HiC2822 (DI), HiC2842 (DI), 24 V DC supply, Hazardous area: sp...</p>
<p>The post <a href="https://centralxl.com/product/pepperl-fuchs-hictb16-him-rac-sp-di320x/">Pepperl Fuchs HiCTB16-HIM-RAC-SP-DI320X</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Termination Board. System board for HIMA, HIMax, For 32-channel cards X-DI 32 01 or X-DI 32 04 (DI), For 16 modules, Recommended modules: HiC2822 (DI), HiC2842 (DI), 24 V DC supply, Hazardous area: spring terminals, blue, Non-hazardous area: HIMA system connector, 96-pin, Number of modules: 16, Signal type: Digital Input, Manufacturer: HIMA, Control system type: HIMax. Connection: XG2: terminals 1, 3 (+); 2, 4 (-). Nominal voltage: 24 V DC , in consideration of rated voltage of used isolators. Voltage drop: 0.9 V , voltage drop across the series diode on the termination board must be considered. Ripple: ≤ 10 %. Fusing: 4 A , in each case for 16 modules. Power dissipation: ≤ 500 mW , without modules. Reverse polarity protection: yes. Supply: Redundancy available. The supply for the isolators is decoupled, monitored and fused.. Connection: XG2: terminals 5, 6. Output type: volt-free contact. Switch behaviour: no fault: relay contact closed power supply fault: relay contact open module fault: relay contact open. Contact loading: 30 V DC, 1 A. Display elements: LED PWR1 (termination board power supply), green LEDLED PWR2 (termination board power supply), green LED LED FAULT (fault indication), red LED- LED lits: power supply fault- LED flashes: module fault LED Run, green LED- The HIMax I/O module is supplied with power and is connected to the Termination Board (FTA) via a system cable.LED Field, red LED- The HIMax I/O module detects faults in the connection between HIMax I/O module and Termination Board (FTA).. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013 (industrial locations): . Directive 2014/30/EU: EN 61326-1:2013 (industrial locations). Electromagnetic compatibility: NE 21:2017For further information see system description.. Degree of protection: IEC 60529:2001. Ambient temperature: -20 &#8230; 60 °C (-4 &#8230; 140 °F). Storage temperature: -40 &#8230; 85 °C (-40 &#8230; 185 °F). Degree of protection: IP20. Connection: . Field sideexplosion hazardous area: spring terminals , blueControl sidenon-explosion hazardous area: HIMA system connector, 96-pinSupplypluggable spring terminals , blackFault outputpluggable spring terminals , black: . Field side: explosion hazardous area: spring terminals , blue. Control side: non-explosion hazardous area: HIMA system connector, 96-pin. Supply: pluggable spring terminals , black. Fault output: pluggable spring terminals , black. Core cross section: spring terminals: 0.25 &#8230; 1.5 mm2 (24 &#8230; 16 AWG). Material: housing: polycarbonate, 10 % glass fiber reinforced. Mass: approx. 785 g. Dimensions: 266 x 200 x 163 mm (10.5 x 7.9 x 6.42 inch) (W x H x D) , depth including module assembly. Height200 mmWidth266 mmDepth163 mm: . Height: 200 mm. Width: 266 mm. Depth: 163 mm. Mounting: on 35 mm DIN mounting rail acc. to EN 60715:2001. EU-type examination certificate: CESI 06 ATEX 022. Marking II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I: . Marking: II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I. Non-hazardous area: . Maximum safe voltage250 V (Attention! Um is no rated voltage.): . Maximum safe voltage: 250 V (Attention! Um is no rated voltage.). Galvanic isolation: . Field circuit/control circuitsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V: . Field circuit/control circuit: safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 50303:2000: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 50303:2000. UL approval: E106378. Control drawing116-0327: . Control drawing: 116-0327. IECEx approval: . IECEx certificateIECEx CES 06.0003IECEx marking[Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Ma] I: . IECEx certificate: IECEx CES 06.0003. IECEx marking: [Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Ma] I. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.</p>
<p>The post <a href="https://centralxl.com/product/pepperl-fuchs-hictb16-him-rac-sp-di320x/">Pepperl Fuchs HiCTB16-HIM-RAC-SP-DI320X</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://centralxl.com/product/pepperl-fuchs-hictb16-him-rac-sp-di320x/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Pepperl Fuchs HiCTB16-UNI-D16SFR-SP-SP</title>
		<link>https://centralxl.com/product/pepperl-fuchs-hictb16-uni-d16sfr-sp-sp/</link>
					<comments>https://centralxl.com/product/pepperl-fuchs-hictb16-uni-d16sfr-sp-sp/#respond</comments>
		
		<dc:creator><![CDATA[sales@partnerplc.com]]></dc:creator>
		<pubDate>Tue, 20 Jan 2026 13:27:28 +0000</pubDate>
				<guid isPermaLink="false">https://centralxl.com/product/pepperl-fuchs-hictb16-uni-d16sfr-sp-sp/</guid>

					<description><![CDATA[<p>Termination Board. For 16 modules, 24 V DC supply, Supported signal types: DI/DO/AI/TI/AO, Module supply fused separately, Hazardous area: spring terminals, blue, Non-hazardous area: spring terminals,...</p>
<p>The post <a href="https://centralxl.com/product/pepperl-fuchs-hictb16-uni-d16sfr-sp-sp/">Pepperl Fuchs HiCTB16-UNI-D16SFR-SP-SP</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Termination Board. For 16 modules, 24 V DC supply, Supported signal types: DI/DO/AI/TI/AO, Module supply fused separately, Hazardous area: spring terminals, blue, Non-hazardous area: spring terminals, black, Number of modules: 16, Signal type: Universal, Manufacturer: Generic, Control system type: Universal. Connection: X20: terminals 3, 5(+); 4, 6(-). Nominal voltage: 24 V DC , in consideration of rated voltage of used isolators. Voltage drop: 0.9 V , voltage drop across the series diode on the termination board must be considered. Ripple: ≤ 10 %. Fusing: 250 mA per module. Power dissipation: ≤ 500 mW , without modules. Reverse polarity protection: yes. Supply: Redundancy available. The supply for the isolators is decoupled, monitored and fused.. Connection: fault bus (Fault) : X20: terminals 1, 2. Output type: volt-free contact. Switch behaviour: fault bus (Fault)- no fault: relay contact of the fault indication board closed- power supply fault: relay contact of the fault indication board open- module fault: relay contact of the fault indication board open. Contact loading: fault bus (Fault) : 30 V DC , 1 A , see fault indication board. Display elements: LED Supply1 (power supply termination board), green LEDLED Supply2 (power supply termination board), green LED. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013 (industrial locations): . Directive 2014/30/EU: EN 61326-1:2013 (industrial locations). Electromagnetic compatibility: NE 21:2017For further information see system description.. Degree of protection: IEC 60529:2001. Ambient temperature: -20 &#8230; 60 °C (-4 &#8230; 140 °F). Storage temperature: -40 &#8230; 70 °C (-40 &#8230; 158 °F). Degree of protection: IP20. Connection: . Field sideexplosion hazardous area: spring terminals , blueControl sidenon-explosion hazardous area: spring terminals , blackSupplypluggable screw terminals , blackFault outputpluggable screw terminals , black: . Field side: explosion hazardous area: spring terminals , blue. Control side: non-explosion hazardous area: spring terminals , black. Supply: pluggable screw terminals , black. Fault output: pluggable screw terminals , black. Core cross section: screw terminals: 0.25 &#8230; 1.5 mm2 (24 &#8230; 16 AWG). Material: housing: polycarbonate, 10 % glass fiber reinforced. Mass: approx. 810 g. Dimensions: 216 x 200 x 163 mm (8.5 x 7.9 x 6.42 inch) (W x H x D) , depth including module assembly. Height200 mmWidth216 mmDepth163 mm: . Height: 200 mm. Width: 216 mm. Depth: 163 mm. Mounting: on 35 mm DIN mounting rail acc. to EN 60715:2001. EU-type examination certificate: CESI 06 ATEX 022. Marking II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I: . Marking: II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I. Non-hazardous area: . Maximum safe voltage250 V (Attention! Um is no rated voltage.): . Maximum safe voltage: 250 V (Attention! Um is no rated voltage.). Galvanic isolation: . Field circuit/control circuitsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V: . Field circuit/control circuit: safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 50303:2000: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 50303:2000. UL approval: E106378. Control drawing116-0327: . Control drawing: 116-0327. IECEx approval: . IECEx certificateIECEx CES 06.0003IECEx marking[Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Ma] I: . IECEx certificate: IECEx CES 06.0003. IECEx marking: [Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Ma] I. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.</p>
<p>The post <a href="https://centralxl.com/product/pepperl-fuchs-hictb16-uni-d16sfr-sp-sp/">Pepperl Fuchs HiCTB16-UNI-D16SFR-SP-SP</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://centralxl.com/product/pepperl-fuchs-hictb16-uni-d16sfr-sp-sp/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Pepperl Fuchs HiCTB16-HIM-RAC-SP-DI3202</title>
		<link>https://centralxl.com/product/pepperl-fuchs-hictb16-him-rac-sp-di3202/</link>
					<comments>https://centralxl.com/product/pepperl-fuchs-hictb16-him-rac-sp-di3202/#respond</comments>
		
		<dc:creator><![CDATA[sales@partnerplc.com]]></dc:creator>
		<pubDate>Tue, 20 Jan 2026 13:27:27 +0000</pubDate>
				<guid isPermaLink="false">https://centralxl.com/product/pepperl-fuchs-hictb16-him-rac-sp-di3202/</guid>

					<description><![CDATA[<p>Termination Board. System board for HIMA, HIMax, For 32-channel card X-DI 32 02 (DI), For 16 modules, Recommended module: HiC2832 (DI), 24 V DC supply, Hazardous area: spring terminals, blue, Non-haza...</p>
<p>The post <a href="https://centralxl.com/product/pepperl-fuchs-hictb16-him-rac-sp-di3202/">Pepperl Fuchs HiCTB16-HIM-RAC-SP-DI3202</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Termination Board. System board for HIMA, HIMax, For 32-channel card X-DI 32 02 (DI), For 16 modules, Recommended module: HiC2832 (DI), 24 V DC supply, Hazardous area: spring terminals, blue, Non-hazardous area: HIMA system connector, 96-pin, Number of modules: 16, Signal type: Digital Input, Manufacturer: HIMA, Control system type: HIMax. Connection: XG2: terminals 1, 3 (+); 2, 4 (-). Nominal voltage: 24 V DC , in consideration of rated voltage of used isolators. Voltage drop: 0.9 V , voltage drop across the series diode on the termination board must be considered. Ripple: ≤ 10 %. Fusing: 4 A , in each case for 16 modules. Power dissipation: ≤ 500 mW , without modules. Reverse polarity protection: yes. Supply: Redundancy available. The supply for the isolators is decoupled, monitored and fused.. Connection: XG2: terminals 5, 6. Output type: volt-free contact. Switch behaviour: no fault: relay contact closed power supply fault: relay contact open module fault: relay contact open. Contact loading: 30 V DC, 1 A. Display elements: LED PWR1 (termination board power supply), green LEDLED PWR2 (termination board power supply), green LED LED FAULT (fault indication), red LED- LED lits: power supply fault- LED flashes: module fault LED Run, green LED- The HIMax I/O module is supplied with power and is connected to the Termination Board (FTA) via a system cable.LED Field, red LED- The HIMax I/O module detects faults in the connection between HIMax I/O module and Termination Board (FTA).. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013 (industrial locations): . Directive 2014/30/EU: EN 61326-1:2013 (industrial locations). Electromagnetic compatibility: NE 21:2017For further information see system description.. Degree of protection: IEC 60529:2001. Ambient temperature: -20 &#8230; 60 °C (-4 &#8230; 140 °F). Storage temperature: -40 &#8230; 85 °C (-40 &#8230; 185 °F). Degree of protection: IP20. Connection: . Field sideexplosion hazardous area: spring terminals , blueControl sidenon-explosion hazardous area: HIMA system connector, 96-pinSupplypluggable spring terminals , blackFault outputpluggable spring terminals , black: . Field side: explosion hazardous area: spring terminals , blue. Control side: non-explosion hazardous area: HIMA system connector, 96-pin. Supply: pluggable spring terminals , black. Fault output: pluggable spring terminals , black. Core cross section: spring terminals: 0.25 &#8230; 1.5 mm2 (24 &#8230; 16 AWG). Material: housing: polycarbonate, 10 % glass fiber reinforced. Mass: approx. 790 g. Dimensions: 266 x 200 x 163 mm (10.5 x 7.9 x 6.42 inch) (W x H x D) , depth including module assembly. Height200 mmWidth266 mmDepth163 mm: . Height: 200 mm. Width: 266 mm. Depth: 163 mm. Mounting: on 35 mm DIN mounting rail acc. to EN 60715:2001. EU-type examination certificate: CESI 06 ATEX 022. Marking II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I: . Marking: II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I. Non-hazardous area: . Maximum safe voltage250 V (Attention! Um is no rated voltage.): . Maximum safe voltage: 250 V (Attention! Um is no rated voltage.). Galvanic isolation: . Field circuit/control circuitsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V: . Field circuit/control circuit: safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 50303:2000: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 50303:2000. UL approval: E106378. Control drawing116-0327: . Control drawing: 116-0327. IECEx approval: . IECEx certificateIECEx CES 06.0003IECEx marking[Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Ma] I: . IECEx certificate: IECEx CES 06.0003. IECEx marking: [Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Ma] I. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.</p>
<p>The post <a href="https://centralxl.com/product/pepperl-fuchs-hictb16-him-rac-sp-di3202/">Pepperl Fuchs HiCTB16-HIM-RAC-SP-DI3202</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://centralxl.com/product/pepperl-fuchs-hictb16-him-rac-sp-di3202/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Pepperl Fuchs HiCTB16-FBM-RSC-SP-DO16</title>
		<link>https://centralxl.com/product/pepperl-fuchs-hictb16-fbm-rsc-sp-do16/</link>
					<comments>https://centralxl.com/product/pepperl-fuchs-hictb16-fbm-rsc-sp-do16/#respond</comments>
		
		<dc:creator><![CDATA[sales@partnerplc.com]]></dc:creator>
		<pubDate>Tue, 20 Jan 2026 13:27:26 +0000</pubDate>
				<guid isPermaLink="false">https://centralxl.com/product/pepperl-fuchs-hictb16-fbm-rsc-sp-do16/</guid>

					<description><![CDATA[<p>Termination Board. System board for Schneider, Foxboro FBM series, For 16 modules, For 16-channel DO card FBM242c, 24 V DC supply, Recommended modules: HiC2871A (DO), HiC2883 (DO), Hazardous area: spr...</p>
<p>The post <a href="https://centralxl.com/product/pepperl-fuchs-hictb16-fbm-rsc-sp-do16/">Pepperl Fuchs HiCTB16-FBM-RSC-SP-DO16</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Termination Board. System board for Schneider, Foxboro FBM series, For 16 modules, For 16-channel DO card FBM242c, 24 V DC supply, Recommended modules: HiC2871A (DO), HiC2883 (DO), Hazardous area: spring terminals, blue, Non-hazardous area: Sub-D connector (male), 37-pin, Number of modules: 16, Signal type: Digital Output, Manufacturer: Foxboro, Control system type: FBM. Connection: X20: terminals 3, 5(+); 4, 6(-). Nominal voltage: 24 V DC , in consideration of rated voltage of used isolators. Voltage drop: 0.9 V , voltage drop across the series diode on the termination board must be considered. Ripple: ≤ 10 %. Fusing: 4 A , in each case for 16 modules. Power dissipation: ≤ 500 mW , without modules. Reverse polarity protection: yes. Supply: Redundancy available. The supply for the isolators is decoupled, monitored and fused.. Connection: X20: terminals 1, 2. Output type: volt-free contact. Switch behaviour: no fault: relay contact closed power supply fault: relay contact open. Contact loading: 30 V DC, 1 A. Display elements: LED PWR1 (termination board power supply), green LEDLED PWR2 (termination board power supply), green LED LED FAULT (fault indication), red LED- LED flashes: power supply fault. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013 (industrial locations): . Directive 2014/30/EU: EN 61326-1:2013 (industrial locations). Electromagnetic compatibility: NE 21:2017For further information see system description.. Degree of protection: IEC 60529:2001. Ambient temperature: -20 &#8230; 60 °C (-4 &#8230; 140 °F). Storage temperature: -40 &#8230; 70 °C (-40 &#8230; 158 °F). Degree of protection: IP20. Connection: . Field sideexplosion hazardous area: 4 spring terminals per module , blueControl sidenon-explosion hazardous area: Sub-D connector , 37-pinSupplypluggable spring terminals , blackFault outputpluggable spring terminals , black: . Field side: explosion hazardous area: 4 spring terminals per module , blue. Control side: non-explosion hazardous area: Sub-D connector , 37-pin. Supply: pluggable spring terminals , black. Fault output: pluggable spring terminals , black. Core cross section: 0.25 &#8230; 1.5 mm2 (24 &#8230; 16 AWG). Material: housing: polycarbonate, 10 % glass fiber reinforced. Mass: approx. 655 g. Dimensions: 216 x 200 x 163 mm (8.5 x 7.9 x 6.42 inch) (W x H x D) , depth including module assembly. Height200 mmWidth216 mmDepth163 mm: . Height: 200 mm. Width: 216 mm. Depth: 163 mm. Mounting: on 35 mm DIN mounting rail acc. to EN 60715:2001. EU-type examination certificate: CESI 06 ATEX 022. Marking II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I: . Marking: II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I. Non-hazardous area: . Maximum safe voltage250 V (Attention! Um is no rated voltage.): . Maximum safe voltage: 250 V (Attention! Um is no rated voltage.). Galvanic isolation: . Field circuit/control circuitsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V: . Field circuit/control circuit: safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 50303:2000: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 50303:2000. UL approval: E106378. Control drawing116-0327: . Control drawing: 116-0327. IECEx approval: . IECEx certificateIECEx CES 06.0003IECEx marking[Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Ma] I: . IECEx certificate: IECEx CES 06.0003. IECEx marking: [Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Ma] I. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.</p>
<p>The post <a href="https://centralxl.com/product/pepperl-fuchs-hictb16-fbm-rsc-sp-do16/">Pepperl Fuchs HiCTB16-FBM-RSC-SP-DO16</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://centralxl.com/product/pepperl-fuchs-hictb16-fbm-rsc-sp-do16/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Pepperl Fuchs HiC2031</title>
		<link>https://centralxl.com/product/pepperl-fuchs-hic2031/</link>
					<comments>https://centralxl.com/product/pepperl-fuchs-hic2031/#respond</comments>
		
		<dc:creator><![CDATA[sales@partnerplc.com]]></dc:creator>
		<pubDate>Tue, 20 Jan 2026 13:27:25 +0000</pubDate>
				<guid isPermaLink="false">https://centralxl.com/product/pepperl-fuchs-hic2031/</guid>

					<description><![CDATA[<p>SMART Current Driver. 1-channel isolated barrier, 24 V DC supply (bus powered), Current output up to 650 Ω load, Low power dissipation, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 12.5 mm,...</p>
<p>The post <a href="https://centralxl.com/product/pepperl-fuchs-hic2031/">Pepperl Fuchs HiC2031</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>SMART Current Driver. 1-channel isolated barrier, 24 V DC supply (bus powered), Current output up to 650 Ω load, Low power dissipation, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, Transfer direction: to the field, HART communication, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 &#8230; 30 V DC bus powered via Termination Board, Signal: 1  x 4 &#8230; 20 mA, Field device: 1  x positioner, Field device [2]: 1  x I/P converters. Signal type: Analog output. Safety Integrity Level (SIL): SIL 2. Systematic capability (SC): SC 3. Connection: SL1: 1a(-), 1b(-); 2a(+), 2b(+). Rated voltage: 19 &#8230; 30 V DC bus powered via Termination Board. Ripple: ≤ 10 %. Rated current: ≤ 30 mA at 24 V. Power dissipation: ≤ 600 mW at 20 mA and 500 Ω load. Power consumption: ≤ 700 mW. Connection side: control side. Connection: SL1: 8a(+), 7a(-). Input signal: 4 &#8230; 20 mA , limited to approx. 26 mA. Input voltage: open loop voltage of the control system  100 kΩ, with field wiring open. Connection side: field side. Connection: SL2: 5a(+), 5b(-). Voltage: ≥ 13 V at 20 mA. Current: 4 &#8230; 20 mA. Load: 0 &#8230; 650 Ω. Ripple: 20 mV rms. Deviation: at 20 °C (68 °F), 4 &#8230; 20 mA&lt; 0.1 % of full scale, incl. non-linearity and hysteresis. Influence of ambient temperature&lt; 2 µA/K (-20 &#8230; 70 °C (-4 &#8230; 158 °F)); &lt; 4 µA/K (-40 &#8230; -20 °C (-40 &#8230; -4 °F)): . Influence of ambient temperature: &lt; 2 µA/K (-20 &#8230; 70 °C (-4 &#8230; 158 °F)); &lt; 4 µA/K (-40 &#8230; -20 °C (-40 &#8230; -4 °F)). Frequency range: field side into the control side: bandwidth with 0.5 Vpp signal 0 &#8230; 3 kHz (-3 dB) control side into the field side: bandwidth with 1 mApp signal 0 &#8230; 3 kHz (-3 dB). Rise time: 10 to 90 % ≤ 10 ms. Input/Output: safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V. Input/power supply: basic insulation according to IEC/EN 61010-1, rated insulation voltage 60 Veff. Output/power supply: safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V. Display elements: LED. Labeling: space for labeling at the front. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013 (industrial locations): . Directive 2014/30/EU: EN 61326-1:2013 (industrial locations). Electromagnetic compatibility: NE 21:2017 EN 61326-3-2:2018 For further information see system description.. Degree of protection: IEC 60529:2001. Protection against electrical shock: UL 61010-1:2018. Ambient temperature: -40 &#8230; 70 °C (-40 &#8230; 158 °F). Degree of protection: IP20. Mass: approx. 100 g. Dimensions: 12.5 x 106 x 128 mm (0.5 x 4.2 x 5.1 inch) (W x H x D). Mounting: on termination board. Coding: pin 1 and 3 trimmed For further information see system description.. EU-type examination certificate: CESI 06 ATEX 017. Marking II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] IOutputEx ia: . Marking: II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I. Output: Ex ia. Supply: . Maximum safe voltageUm250 V AC (Attention! Um is no rated voltage.): Um. Maximum safe voltage: 250 V AC (Attention! Um is no rated voltage.). Equipment: SL2: 5a(+), 5b(-). VoltageUo25.2 VCurrentIo100 mAPowerPo630 mWInternal capacitanceCi5.7 nFInternal inductanceLinegligible: Uo. Voltage: 25.2 V. Current: 100 mA. Power: 630 mW. Internal capacitance: 5.7 nF. Internal inductance: negligible. Certificate: CESI 19 ATEX 027 X. Marking II 3G Ex ec IIC T4 Gc: . Marking: II 3G Ex ec IIC T4 Gc. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018 , EN 60079-11:2012 , EN IEC 60079-7:2015/A1:2018: . Directive 2014/34/EU: EN IEC 60079-0:2018 , EN 60079-11:2012 , EN IEC 60079-7:2015/A1:2018. FM approval: . FM certificateFM 19 US 0122 X , FM 19 CA 0065 XControl drawing116-0470 (cFMus): . FM certificate: FM 19 US 0122 X , FM 19 CA 0065 X. Control drawing: 116-0470 (cFMus). UL approval: E106378. Control drawing116-0458 (cULus): . Control drawing: 116-0458 (cULus). IECEx approval: . IECEx certificateIECEx CES 06.0002XIECEx marking[Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I Ex ec IIC T4 Gc: . IECEx certificate: IECEx CES 06.0002X. IECEx marking: [Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I Ex ec IIC T4 Gc. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.</p>
<p>The post <a href="https://centralxl.com/product/pepperl-fuchs-hic2031/">Pepperl Fuchs HiC2031</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://centralxl.com/product/pepperl-fuchs-hic2031/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Pepperl Fuchs HiC2821</title>
		<link>https://centralxl.com/product/pepperl-fuchs-hic2821/</link>
					<comments>https://centralxl.com/product/pepperl-fuchs-hic2821/#respond</comments>
		
		<dc:creator><![CDATA[sales@partnerplc.com]]></dc:creator>
		<pubDate>Tue, 20 Jan 2026 13:27:25 +0000</pubDate>
				<guid isPermaLink="false">https://centralxl.com/product/pepperl-fuchs-hic2821/</guid>

					<description><![CDATA[<p>Switch Amplifier. 1-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR input, Usable as signal splitter (1 input and 2 outputs), 2 relay contact outputs, Fault relay contact...</p>
<p>The post <a href="https://centralxl.com/product/pepperl-fuchs-hic2821/">Pepperl Fuchs HiC2821</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Switch Amplifier. 1-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR input, Usable as signal splitter (1 input and 2 outputs), 2 relay contact outputs, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 19 &#8230; 30 V DC bus powered via Termination Board, Field device: NAMUR sensor, Field device [2]: volt-free contact. Signal type: Digital Input. Safety Integrity Level (SIL): SIL 2. Connection: SL1: 1a(-), 1b(-); 2a(+), 2b(+). Rated voltage: 19 &#8230; 30 V DC bus powered via Termination Board. Ripple: ≤ 10 %. Rated current: ≤ 30 mA. Power dissipation: ≤ 500 mW. Power consumption: ≤ 500 mW. Connection side: field side. Connection: SL2: 5a(+), 5b(-). Rated values: acc. to EN 60947-5-6 (NAMUR), see manual for electrical data. Open circuit voltage/short-circuit current: approx. 10 V DC / approx. 8 mA. Switching point/switching hysteresis: 1.2 &#8230; 2.1 mA / approx. 0.2 mA. Line fault detection: breakage I ≤ 0.1 mA , short-circuit I ≥ 6.7 mA. Pulse/Pause ratio: min. 20 ms / min. 20 ms. Connection side: control side. Connection: SL1: 8a, 7a; 10a, 9a. Output I: signal ; relay. Output II: signal or fault message ; relay. Contact loading: 50 V DC / 0.5 A. Minimum switch current: 2 mA / 24 V DC. Energized/De-energized delay: ≤ 20 ms / ≤ 20 ms. Mechanical life: 107 switching cycles. Connection: SL1: 6b. Output type: open collector transistor (internal fault bus). Switching frequency: ≤ 10 Hz. Output/power supply: basic insulation acc. to EN 50178, rated insulation voltage of 50 V AC. Output/Output: basic insulation acc. to EN 50178, rated insulation voltage of 50 V AC. Display elements: LEDs. Control elements: DIP switch. Configuration: via DIP switches. Labeling: space for labeling at the front. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013 (industrial locations): . Directive 2014/30/EU: EN 61326-1:2013 (industrial locations). Galvanic isolation: EN 50178:1997. Electromagnetic compatibility: EN IEC 61326-3-2:2018 , NE 21:2012For further information see system description.. Degree of protection: IEC 60529:2001. Input: EN 60947-5-6:2000. Ambient temperature: -20 &#8230; 60 °C (-4 &#8230; 140 °F). Degree of protection: IP20. Mass: approx. 100 g. Dimensions: 12.5 x 106 x 128 mm (0.5 x 4.2 x 5.1 inch) (W x H x D). Height106 mmWidth12.5 mmDepth128 mm: . Height: 106 mm. Width: 12.5 mm. Depth: 128 mm. Mounting: on termination board. Coding: pin 1 and 2 trimmed For further information see system description.. EU-type examination certificate: BASEEFA 06 ATEX 0093 X. Marking II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] IInput[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] IVoltageUo10.5 VCurrentIo17.1 mAPowerPo45 mW (linear characteristic): . Marking: II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I. Input: [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I. Voltage: 10.5 V. Current: 17.1 mA. Power: 45 mW (linear characteristic). Supply: . Maximum safe voltageUm253 V AC (Attention! Um is no rated voltage.): Um. Maximum safe voltage: 253 V AC (Attention! Um is no rated voltage.). Output: . Contact loading50 V DC / 0.5 AMaximum safe voltageUm253 V AC (Attention! The rated voltage can be lower.): . Contact loading: 50 V DC / 0.5 A. Maximum safe voltage: 253 V AC (Attention! The rated voltage can be lower.). Certificate: PF 08 CERT 1047 X. Marking II 3G Ex nA nC IIC T4 Gc: . Marking: II 3G Ex nA nC IIC T4 Gc. Galvanic isolation: . Input/Outputsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 VInput/power supplysafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V: . Input/Output: safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V. Input/power supply: safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010. FM approval: . Control drawing16-534FM-12 (cFMus): . Control drawing: 16-534FM-12 (cFMus). UL approval: E106378. Control drawing116-0434: . Control drawing: 116-0434. IECEx approval: . IECEx certificateIECEx BAS 06.0026XIECEx marking[Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Ma] I: . IECEx certificate: IECEx BAS 06.0026X. IECEx marking: [Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Ma] I. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.</p>
<p>The post <a href="https://centralxl.com/product/pepperl-fuchs-hic2821/">Pepperl Fuchs HiC2821</a> appeared first on <a href="https://centralxl.com">CentralXL | Industrial Marketplace</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://centralxl.com/product/pepperl-fuchs-hic2821/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
