B&R 8V1010.50-2

 210,94

3 in stock

Designed for operation on a single-phase or three-phase power mainsModular mechanical design using plug-in modulesIntegrated line filterIntegrated braking resistorIntegrated electronic restart inhibit…

3 in stock

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Designed for operation on a single-phase or three-phase power mainsModular mechanical design using plug-in modulesIntegrated line filterIntegrated braking resistorIntegrated electronic restart inhibit

ACOPOS servo drive, 3x 110-230 V / 1x 110-230 V, 2.3 A, 0.45 kW, integrated line filter, braking resistor and electronic safe restart interlock

Specification

B&R ID code0x18D4
Slots for plug-in modules3
CEYes
UKCAYes
CRA (Cyber Resilience Act)Evaluation ongoing
Functional safetyYes
ULcULus E225616Power conversion equipment
KCYes
Permissible network configurationsTT, TN
Mains input voltage3x 110 VAC to 230 VAC ±10% or 1x 110 VAC to 230 VAC ±10%
Frequency50 / 60 Hz ±4%
Installed loadMax. 1.35 kVA
Inrush current5 A (at 230 VAC)
Switch-on interval>10 s
Integrated line filter per EN 61800-3, category C3Yes
Power dissipation at device nominal power without braking resistor80 W
DC bus capacitance2040 µF
Input voltage24 VDC +25% / -20%
Input capacitance5600 µF
Current consumptionMax. 1.47 A + Current for motor holding brake
Quantity2
Continuous current2.3 Aeff
Switching frequency 5 kHzNo reduction
Switching frequency 10 kHzNo reduction
Switching frequency 20 kHzNo reduction
Starting at 500 m above sea level0.23 Aeff per 1000 m
Peak current7.8 Aeff
Nominal switching frequency10 kHz
Possible switching frequencies5 / 10 / 20 kHz
Insulation stress of the connected motor per IEC TS 60034-25:2004Limit value curve A
Max. motor line length15 m
Overload protectionYes
Short-circuit and ground fault protectionYes
Max. output frequency598 Hz
With wire end sleeve0.25 to 4 mm²
UL/C-UL-US30 to 10 AWG
CSA28 to 10 AWG
Response threshold for open-circuit monitoringApprox. 245 mA
Max. output current1.3 A
Max. number of switching cyclesUnlimited since implemented electronically
Peak power output1.9 kW
Continuous power130 W
CircuitSink
Input - ACOPOSYes
Input - InputNo
Nominal5 to 40°C
Maximum55°C
Low<5 V
High>15 V
Input current at nominal voltageApprox. 10 mA
Switching delayMax. 2.0 ms
Modulation compared to ground potentialMax. ±38 V
Enable 0 → 1, ready for PWMMax. 100 µs
Enable 1 → 0, PWM offMax. 2.0 ms
OSSD signal connectionsNot permitted
Rising edge52 µs ±0.5 µs (digitally filtered)
Falling edge53 µs ±0.5 µs (digitally filtered)
Discharge capacitance330 nF
Power dissipation relative to continuous apparent powerIE2 (10,25) 4.2%IE2 (50,25) 4.2%IE2 (10,50) 4.2%IE2 (50,50) 4.3%IE2 (90,50) 4.4%IE2 (10,100) 4.5%IE2 (50,100) 4.7%IE2 (90,100) 4.9%
Nominal losses in standby mode12.5 W
Hanging verticallyYes
Horizontal, face upYes
Standing horizontallyNo
Pollution degree per EN 61800-5-12 (non-conductive pollution)
Overvoltage category per EN 61800-5-1II
Degree of protection per EN 60529IP20
Storage5 to 95%
TransportMax. 95% at 40°C
Operation5 to 85%
Width58.5 mm
Height257 mm
Depth220 mm
Weight2.5 kg

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.