B&R 8V1016.501-2
Designed for operation on a single-phase or three-phase power mainsModular mechanical design using plug-in modulesIntegrated line filterIntegrated braking resistorIntegrated electronic restart inhibit…
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
From $20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From $40
-
Warranty 1 year
-
Free 30-Day returns
Description
Designed for operation on a single-phase or three-phase power mainsModular mechanical design using plug-in modulesIntegrated line filterIntegrated braking resistorIntegrated electronic restart inhibitPartially-coated circuit boards – more robust in regard to environmental influences
ACOPOS servo drive, 3x 110-230 V / 1x 110-230 V, 3.6 A, 0.7 kW, coated, integrated line filter, braking resistor and electronic safe restart interlock
Specification
| Note |
Variant with partially coated printed circuit boards |
|---|---|
| B&R ID code |
0xA6D7 |
| Slots for plug-in modules |
3 |
| CE |
Yes |
| UKCA |
Yes |
| CRA (Cyber Resilience Act) |
Evaluation ongoing |
| Functional safety |
Yes |
| UL |
cULus E225616Power conversion equipment |
| KC |
Yes |
| Permissible network configurations |
TT, TN |
| Mains input voltage |
3x 110 VAC to 230 VAC ±10% or 1x 110 VAC to 230 VAC ±10% |
| Frequency |
50 / 60 Hz ±4% |
| Installed load |
Max. 2.1 kVA |
| Inrush current |
5 A (at 230 VAC) |
| Switch-on interval |
>10 s |
| Integrated line filter per EN 61800-3, category C3 |
Yes |
| Power dissipation at device nominal power without braking resistor |
110 W |
| DC bus capacitance |
2040 µF |
| Input voltage |
24 VDC +25% / -20% |
| Input capacitance |
5600 µF |
| Current consumption |
Max. 1.47 A + Current for motor holding brake |
| Quantity |
2 |
| Continuous current |
3.6 Aeff |
| Switching frequency 5 kHz |
No reduction |
| Switching frequency 10 kHz |
No reduction |
| Switching frequency 20 kHz |
No reduction |
| Starting at 500 m above sea level |
0.36 Aeff per 1000 m |
| Peak current |
12 Aeff |
| Nominal switching frequency |
10 kHz |
| Possible switching frequencies |
5 / 10 / 20 kHz |
| Insulation stress of the connected motor per IEC TS 60034-25:2004 |
Limit value curve A |
| Max. motor line length |
15 m |
| Overload protection |
Yes |
| Short-circuit and ground fault protection |
Yes |
| Max. output frequency |
598 Hz |
| With wire end sleeve |
0.25 to 4 mm² |
| UL/C-UL-US |
30 to 10 AWG |
| CSA |
28 to 10 AWG |
| Response threshold for open-circuit monitoring |
Approx. 245 mA |
| Max. output current |
1.3 A |
| Max. number of switching cycles |
Unlimited since implemented electronically |
| Peak power output |
1.9 kW |
| Continuous power |
130 W |
| Circuit |
Sink |
| Input - ACOPOS |
Yes |
| Input - Input |
No |
| Nominal |
5 to 40°C |
| Maximum |
55°C |
| Low |
<5 V |
| High |
>15 V |
| Input current at nominal voltage |
Approx. 10 mA |
| Switching delay |
Max. 2.0 ms |
| Modulation compared to ground potential |
Max. ±38 V |
| Enable 0 → 1, ready for PWM |
Max. 100 µs |
| Enable 1 → 0, PWM off |
Max. 2.0 ms |
| OSSD signal connections |
Not permitted |
| Rising edge |
52 µs ±0.5 µs (digitally filtered) |
| Falling edge |
53 µs ±0.5 µs (digitally filtered) |
| Power dissipation relative to continuous apparent power |
IE2 (10,25) 2.7% IE2 (50,25) 2.7% IE2 (10,50) 2.9% IE2 (50,50) 3% IE2 (90,50) 3.1% IE2 (10,100) 3.4% IE2 (50,100) 3.6% IE2 (90,100) 3.9% |
| Nominal losses in standby mode |
12.5 W |
| Hanging vertically |
Yes |
| Horizontal, face up |
Yes |
| Standing horizontally |
No |
| Pollution degree per EN 61800-5-1 |
2 (non-conductive pollution) |
| Overvoltage category per EN 61800-5-1 |
II |
| Degree of protection per EN 60529 |
IP20 |
| Storage |
5 to 95% |
| Transport |
Max. 95% at 40°C |
| Operation |
5 to 85% |
| Width |
58.5 mm |
| Height |
257 mm |
| Depth |
220 mm |
| Weight |
2.5 kg |