B&R 8V1640.001-2

Modular mechanical design using plug-in modulesIntegrated line filterIntegrated or optional external braking resistorIntegrated electronic restart inhibitPartially-coated circuit boards – more robust…

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

2-3 Days

From $20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From $40

  • Warranty 1 year
  • Free 30-Day returns

Description

Modular mechanical design using plug-in modulesIntegrated line filterIntegrated or optional external braking resistorIntegrated electronic restart inhibitPartially-coated circuit boards – more robust in regard to environmental influences (8Vxxxx.001-2)

ACOPOS servo drive, 3x 400-480 V, 64 A, 32 kW, coated, integrated line filter, braking resistor, DC bus power supply unit and electronic safe restart interlock

Specification

Note

Variant with partially coated printed circuit boards

B&R ID code

0xA09C

Slots for plug-in modules

4

CE

Yes

UKCA

Yes

CRA (Cyber Resilience Act)

Evaluation ongoing

Functional safety

Yes

UL

cULus E225616
Power conversion equipment

KC

Yes

Permissible network configurations

TT, TN

Mains input voltage

3x 400 VAC to 480 VAC ±10%

Frequency

50 / 60 Hz ±4%

Installed load

Max. 54 kVA

Inrush current at 400 VAC

26 A

Switch-on interval

>10 s

Integrated line filter per EN 61800-3, category C3

Yes

Power dissipation at device nominal power without braking resistor

Approx. 1600 W

DC bus capacitance

3300 µF

Input voltage

24 VDC +25% / -20%

Input capacitance

32,800 µF

Mains input voltage applied

22 to 24 VDC

Mains input voltage not applied

16.7 to 30 VDC

Switch-on voltage

455 VDC

Output current

Max. 0.5 A

Quantity

2

Continuous current

64 Aeff

Switching frequency 5 kHz

No reduction

Switching frequency 10 kHz

0.96 Aeff per °C (starting at 50°C)

Switching frequency 20 kHz

0.96 Aeff per °C (starting at 10°C)

Starting at 500 m above sea level

6.4 Aeff per 1000 m

Peak current

200 Aeff

Nominal switching frequency

10 kHz

Possible switching frequencies

5 / 10 / 20 kHz

Insulation stress of the connected motor per IEC TS 60034-25:2004

Limit value curve A

Max. motor line length

25 m

Overload protection

Yes

Short-circuit and ground fault protection

Yes

Max. output frequency

598 Hz

With wire end sleeve

10 to 35 mm²

UL/C-UL-US

10 to 2 AWG

CSA

10 to 2 AWG

Response threshold for open-circuit monitoring

Approx. 210 mA

Max. output current

3 A

Max. number of switching cycles

Approx. 80,000

Peak power int./ext.

7 / 250 kW

Continuous power int./ext.

0.2 / 24 kW

Minimum braking resistance (ext.)

2.5 Ω

Rated current of built-in fuse

30 A (fast-acting)

Circuit

Sink

Input - ACOPOS

Yes

Input - Input

No

Nominal

5 to 40°C

Maximum

55°C

Low

<5 V

High

>15 V

Input current at nominal voltage

Approx. 10 mA

Switching delay

Max. 2.0 ms

Modulation compared to ground potential

Max. ±38 V

Enable 0 → 1, ready for PWM

Max. 100 µs

Enable 1 → 0, PWM off

Max. 2.0 ms

OSSD signal connections

Not permitted

Rising edge

52 µs ±0.5 µs (digitally filtered)

Falling edge

53 µs ±0.5 µs (digitally filtered)

Discharge capacitance

5.4 µF

Power dissipation relative to continuous apparent power

IE2 (10,25) 0.9%
IE2 (50,25) 0.9%
IE2 (10,50) 1.1%
IE2 (50,50) 1.2%
IE2 (90,50) 1.3%
IE2 (10,100) 1.7%
IE2 (50,100) 2%
IE2 (90,100) 2.3%

Nominal losses in standby mode

32 W

Hanging vertically

Yes

Horizontal, face up

Yes

Standing horizontally

No

Pollution degree per EN 61800-5-1

2 (non-conductive pollution)

Overvoltage category per EN 61800-5-1

II

Degree of protection per EN 60529

IP20

Storage

5 to 95%

Transport

Max. 95% at 40°C

Operation

5 to 85%

Width

276 mm

Height

460 mm

Depth

295 mm

Weight

24.1 kg