B&R 8BVE0500HC00.000-1

For distributing the DC bus power supply and 24 VDC auxiliary supply to multiple mounting platesFor setting up decentralized units in the ACOPOSmulti drive systemOutput for overload protection…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

For distributing the DC bus power supply and 24 VDC auxiliary supply to multiple mounting platesFor setting up decentralized units in the ACOPOSmulti drive systemOutput for overload protection

ACOPOSmulti expansion module 40 A, AS, cold plate or pass-through mounting

Specification

Cooling and mounting typeCold plate or pass-through mounting
CEYes
UKCAYes
CRA (Cyber Resilience Act)Not applicable
ULcULus E225616Power conversion equipment
KCYes
Nominal5 to 40°C
10 ANo (overload indicated via LED, dry alarm contacts present)
20 ANo (overload indicated via LED, dry alarm contacts present)
50 ANo (overload indicated via LED, dry alarm contacts present)
Reduction of continuous power at ambient temperatures starting at 40°C1.25% per °Kelvin
Starting at 500 m above sea level10% per 1000 m
Reduction of continuous power depending on cooling methodNo reduction
Power dissipation with continuous power200 W
VariantACOPOSmulti backplane
Input voltage25 VDC ±1.6%
12 A240 W
30 A600 W
Max. power consumption5 W
Quantity2
TypeMelting fuse ø 10 x 38 mm
Tripping characteristicFast-acting
Rated current12 / 30 A
Short-circuit and ground fault protectionYes
Max. line length between two expansion modules5 m
DC+, DC-, PEConnector
Shield connectionNo
With wire end sleeve0.25 to 6 mm²
UL/C-UL-US22 to 10 AWG
CSA22 to 10 AWG
Terminal cable cross section dimension of shield connection12 to 22 mm
DC bus voltage (UDC): 260 to 315 VDC25 VDC * (DC bus voltage / 315)
DC bus voltage (UDC): 315 to 800 VDC24 VDC ±6%
Overload protectionYes
Short-circuit proofNo
24 VDC, COMConnector
Alarm contact 1Normally closed contact
Alarm contact 2Normally open contact
Alarm contact - ACOPOSmulti moduleYes
Alarm contact - Alarm contactYes
Nominal voltage30 VDC
Maximum current1 A
Switching delay3 ms
Max. number of switching cycles100,000
Overload-proofNo
Hanging verticallyYes
Horizontal, face upYes
Standing horizontallyNo
Maximum55°C
Pollution degree per EN 61800-5-12 (non-conductive pollution)
Overvoltage category per EN 61800-5-1III
Degree of protection per EN 60529IP20
Storage5 to 95%
TransportMax. 95% at 40°C
Operation5 to 85%
Width53 mm
Height317 mm
Cold plate212 mm
Pass-through mounting209 mm
WeightApprox. 2.6 kg
Module width1