Fast delivery within 72 Hours

Wago 857-369

Relay module; Nominal input voltage: 24 … 230 V AC/DC; 1 changeover contact; Limiting continuous current: 6 A; with gold contacts; Yellow status indicator; Module width: 6 mm 857-369

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Relay module; Nominal input voltage: 24 … 230 V AC/DC; 1 changeover contact; Limiting continuous current: 6 A; with gold contacts; Yellow status indicator; Module width: 6 mm 857-369

Specification

Notes

Safety InformationAdjacent devices of the same type are devices of the same design (series) that are arranged next to one another on the DIN-rail with the same orientation. An end stop (249-116) must be fitted to devices of other types for compliance with the reinforced insulation requirements.
NoteTo prevent damaging the gold layer, 30 V switching voltages and 50 mA currents must not be exceeded. Higher switching power eventually evaporates the gold layer. The resulting deposits in the housing may reduce service life., To protect the relay coils and contacts, inductive loads must be dampened with an effective protection circuit.

Technical data - Control circuit

Nominal input voltage U<sub>N</sub>24 … 230 VAC/VDC
Input voltage range-30 … +10 %
Nominal input current at U<sub>N</sub>4 mA (230 VAC); 20 mA (24 VDC)
Nominal frequency range (input voltage)50 … 60 HzAC / 0 HzDC

Technical data - Load circuit

Number of changeover/switchover contacts1
Contact material (relay)AgNi + Au
Limiting continuous current6 A
Inrush current (resistive) max.(AC) 20 A / 0.02 s
Switching Voltage, Max.250 VAC
Switching power (resistive) max.AC 1500 VA; DC (see load limit curve)
Switching capacityAC-15: 3 A / 250 VAC; DC-13: 2 A / 24 VDC
Recommended minimum load1 V / 1 mA / 1 mW
Pull-in time (typ.)15 ms
Drop-out time (typ.)25 ms
Bounce time (typ.)3.5 ms
Electrical life (NO; resistive load; 23 °C)50 x 10³ switching operations
Mechanical life5 x 10⁶ switching operations
Switching frequency with/without load (max.)6 min-1 / 60 min-1

Technical data - Signaling

Status indicatorYellow LED

Safety and protection

Rated voltage300 V
Rated impulse withstand voltage4 kV
Type of circuitsMains circuits
Overvoltage categoryIII
Pollution degree2
Dielectric strength (control/load circuit) (AC, 1 min)3.51 kVrms
Dielectric strength (open contact) (AC, 1 min)1 kVrms
Insulation type (control/load circuit)Reinforced insulation (safe isolation)
Insulation type (between adjacent devices of the same type)Double insulation (safe isolation)
Insulation type (to adjacent devices of different types)Basic insulation
Safety InformationAdjacent devices of the same type are devices of the same design (series) that are arranged next to one another on the DIN-rail with the same orientation. An end stop (249-116) must be fitted to devices of other types for compliance with the reinforced insulation requirements.
Protection typeIP20

Connection data

Connection technologyPush-in CAGE CLAMP®
Solid conductor0.34 … 2.5 mm² / 22 … 14 AWG
Fine-stranded conductor0.34 … 2.5 mm² / 22 … 14 AWG
Fine-stranded conductor; with insulated ferrule0.34 … 1.5 mm² / 22 … 16 AWG
Strip length9 … 10 mm / 0.35 … 0.39 inches

Physical data

Width6 mm / 0.236 inches
Height94 mm / 3.701 inches
Depth from upper-edge of DIN-rail81 mm / 3.189 inches

Mechanical data

Mounting typeDIN-35 rail
Mounting positionHorizontal (standing/lying); vertical

Material data

Note (material data)Information on material specifications can be found here
Insulation material (main housing)Polyamide (PA66)
Material groupI
Flammability class per UL94V0
Fire load0.484 MJ
Weight31.9 g

Environmental requirements

Ambient temperature (operation at U<sub>N</sub>)-25 … +70 °C
Ambient temperature (storage)-40 … +70 °C
Processing temperature-25 … +50 °C
Temperature range of connection cable≥ (Tambient + 30 K)
Relative humidity5 … 85 % (no condensation permissible)
Operating altitude (max.)2000 m

Standards and specifications

Standards/specificationsEN 50121-3-2, EN 61010-2-201, EN 61810-1, EN 61373, EN 61000-6-2, EN 61000-6-3, EN 50121-3, UL 508

Basic relay

WAGO Basic Relay857-151

Commercial data

PU (SPU)25 (1) pcs
Packaging typebox
Country of originDE
GTIN4050821854241
Customs tariff number85364900990

Product Classification

UNSPSC39122325
eCl@ss 10.027-37-16-01
eCl@ss 9.027-37-16-01
ETIM 9.0EC001437
ETIM 10.0EC001437
ECCNNO US CLASSIFICATION

Environmental Product Compliance

CAS-No.1303-86-2, 1317-36-8, 7439-92-1, 79-94-7
REACH Candidate List Substance2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol, Diboron trioxide, Lead, Lead monoxide
RoHS Compliance StatusCompliant,With Exemption
RoHS Exemption6(c), 7(a), 7(c)-I, 7(c)-II
SCIP notification number (Austria)0891d92a-b9b0-4855-a374-3f4c7d8bcec6
SCIP notification number (Belgium)3d6ce96b-95c2-45ca-9c75-c48432a5185f
SCIP notification number (Bulgaria)3eb596a0-fb70-479d-aa2f-992ee8d6da2a
SCIP notification number (Czech Republic)b067e2e6-b27e-489d-b6ce-e8a58bf12ab3
SCIP notification number (Denmark)736ec7f4-e597-4f9a-9f8d-e6e1d89224cb
SCIP notification number (Finland)0e46608a-ada5-42bc-a1e2-3cd98f6f5117
SCIP notification number (France)ce145d34-e7ee-4421-ba57-5016df2c4aa9
SCIP notification number (Germany)cf5584f3-5fcd-4275-b373-70c672f11f18
SCIP notification number (Hungary)7b26aae5-cb7d-40b7-becb-f97e3d03ff32
SCIP notification number (Italy)d63eee63-1ca0-49a7-bcf1-e4345d48419d
SCIP notification number (Netherlands)ce9882fe-9872-4be0-9614-5bcdf964b46a
SCIP notification number (Poland)1482eef4-4a89-4cd2-bd10-fe7e0efba63f
SCIP notification number (Romania)a3805355-5493-4993-bb06-a6fab5877d65
SCIP notification number (Sweden)75a7959b-0f84-4330-8630-470a2d3b43e1

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Wago 857-369”

Your email address will not be published. Required fields are marked *