Short description:WAGO’s module signals a value falling below a non-adjustable, asymmetric isolation resistance between +24 V or 0 V of the supply voltage and ground with a potential-free (Iso OK) contact and status LED. The Iso OK contact can be evaluated via a PLC.This status is maintained until the next measurement interval.Operation with Grounded Control Circuit (Functional Potential Equalization):The module establishes an internal connection between the 0 V (X2.2) and ground (X2.1) connections via a semiconductor switch.At 10 s intervals, this connection between 0 V and ground is interrupted for 0.5 s, and the isolation resistance between +24 V (X1.3) or 0 V (X2.2) of the supply voltage and earth (X2.1) is determined.The grounding connection on the module does not meet the requirements of a protective earth terminal (PE). It serves as a functional ground. The measurement method does not involve the module establishing any permanent connection between 0 V and ground.Operation with Ungrounded Control CircuitIn this operating mode, the semiconductor switch to establish a connection between 0 V (X2.2) and ground (X2.1) is deactivated. At 1 s intervals, the isolation resistance offset is determined for 0.5 s.The module does not meet the requirements of an isolation monitoring device per EN 61557-8.“Iso OK” Contact:The potential-free contact serves the purpose of supporting evaluation (e.g., via a PLC) of looming isolation faults.This contact must not be used to switch safety-related products that could cause the circuit to switch off.
Specification
Power supply
| Nominal supply voltage U<sub>S</sub> | 24 VDC (SELV) |
|---|---|
| Supply voltage range (DC) | 18 … 31.2 VDC |
| Current consumption at nominal supply voltage | ≤ 40 mA |
| Power loss P<sub>l</sub> | ≤ 1.7 W |
| Current at ground fault (24 VDC) max. | 56 mA |
Signaling
| Operation status indicator | 1 x LED status OK (green) |
|---|---|
| Signaling | 1 x Iso alarm LED (red), 1 x Iso-Alarm LED 24 V − Ground (yellow), 1 x Iso-Alarm LED 0 V − Ground (yellow), 1 x Iso-OK signal output |
Iso OK contact
| Switching voltage (max.) | 48 VDC (SELV) |
|---|---|
| Continuous current (max.) | 500 mA (for general use) |
| Number of Iso OK contacts connected in series (max.) | 25 (Limit value type: 1); 32 (Limit value type: 2 and 3) (per IEC 61131) |
| Function | 1 make contact (NO); closed with applied power supply and insulation resistance > limit value |
Circuit protection
| Pre-fuse (required) | The fuse must be placed in the output circuit of the power supply. The fuse must be adapted to the power supply used and must trip safely in case of a short circuit. The module is designed for use with a 10 A (max. ) fuse or with a 10 ADC (max.) circuit breaker (characteristic B or C). |
|---|
Safety and protection
| Pollution degree | 2 |
|---|---|
| Overvoltage category | II |
| Protection type | IP20 |
| Test voltage (supply/Iso OK contact) | 1.5 kVAC; 50 … 60 Hz; 1 min |
| MTBF | > 600,000 h (per MIL-HDBK-217F2) |
Mode: Ungrounded circuit
| Response value for alarm at nominal voltage | 4 kΩ (at US = 24 V; for other US values see diagram for signaling threshold) |
|---|---|
| Response time | 1 s |
| Hysteresis (typ.) | 1 kΩ |
Mode: Grounded circuit
| Response value for alarm at nominal voltage | 4 kΩ (at US = 24 V; for other US values see diagram for signaling threshold) |
|---|---|
| Response time | 10 s |
| Hysteresis (typ.) | 1 kΩ |
Connection data - Connection 1
| Connection type | X1.x |
|---|---|
| Connection technology | Push-in CAGE CLAMP® |
| WAGO connector | picoMAX® eCOM |
| Solid conductor | 0.25 … 1.5 mm² / 24 … 14 AWG |
| Fine-stranded conductor | 0.25 … 1.5 mm² / 24 … 14 AWG |
| Fine-stranded conductor; with insulated ferrule | 0.25 … 0.75 mm² |
| Fine-stranded conductor; with uninsulated ferrule | 0.25 … 1.5 mm² |
| Strip length | 8 … 9 mm / 0.31 … 0.35 inches |
Connection data - Connection 2
| Connection type | X2.x |
|---|---|
| Connection technology | Push-in CAGE CLAMP® |
| WAGO connector | picoMAX® eCOM |
| Solid conductor | 0.2 … 2.5 mm² / 24 … 12 AWG |
| Fine-stranded conductor | 0.2 … 2.5 mm² / 24 … 14 AWG |
| Fine-stranded conductor; with insulated ferrule | 0.25 … 1.5 mm² |
| Fine-stranded conductor; with uninsulated ferrule | 0.25 … 2.5 mm² |
| Strip length | 9 … 10 mm / 0.35 … 0.39 inches |
Physical data
| Width | 18 mm / 0.71 inches |
|---|---|
| Height | 90 mm / 3.54 inches |
| Depth from upper-edge of DIN-rail | 51 mm / 2.01 inches |
Mechanical data
| Mounting type | DIN-35 rail |
|---|
Material data
| Weight | 47 g |
|---|
Environmental requirements
| Ambient temperature (operation) | -40 … +70 °C |
|---|---|
| Ambient temperature (storage) | -40 … +85 °C |
| Temperature range of connection cable | ≥ (Tambient + 10 K) |
| Relative humidity | 5 … 95 % (non-condensing) |
| Operating altitude (max.) | 3000 m |
Standards and specifications
| Conformity marking | CE |
|---|---|
| EMC immunity to interference | EN 61000-6-2 |
| EMC emission of interference | EN 61000-6-3; EN 61000-6-4 |
| Standards/specifications | UL 61010-2-201 |
Commercial data
| PU (SPU) | 1 pcs |
|---|---|
| Packaging type | Box |
| Country of origin | CN |
| GTIN | 4066966120820 |
| Customs tariff number | 85365005000 |
Product Classification
| UNSPSC | 39122221 |
|---|---|
| ETIM 9.0 | EC003596 |
| ETIM 10.0 | EC003596 |
| ECCN | NO US CLASSIFICATION |
Environmental Product Compliance
| CAS-No. | 12060-00-3, 1303-86-2, 1317-36-8, 540-97-6, 541-02-6, 556-67-2, 7439-92-1, 80-05-7 |
|---|---|
| REACH Candidate List Substance | 4,4'-isopropylidenediphenol, Decamethylcyclopentasiloxane [D5], Diboron trioxide, Dodecamethylcyclohexasiloxane [D6], Lead, Lead monoxide, Lead titanium oxide (PbTiO3), Octamethylcyclotetrasiloxane [D4] |
| RoHS Compliance Status | Compliant,With Exemption |
| RoHS Exemption | 6(c), 7(a), 7(c)-I, 7(c)-II |
| SCIP notification number (Austria) | 7e2beec6-e444-4533-91ed-ca9c06e08018 |
| SCIP notification number (Belgium) | 3d57bc60-34df-4908-9ee3-46195d31d01a |
| SCIP notification number (Bulgaria) | 5e35ef1c-882c-48b4-8b73-1d7ec4268ba3 |
| SCIP notification number (Czech Republic) | b6cda593-ddd9-42ff-b4e7-d8fcd1e40d5c |
| SCIP notification number (Denmark) | a3c41961-0b22-4291-9060-47097b5f95ce |
| SCIP notification number (Finland) | 91651202-849e-4dc4-bc7a-b390c932d8de |
| SCIP notification number (France) | d9de80e6-426d-467f-b505-f4cca3e47f38 |
| SCIP notification number (Germany) | 70fe8401-9bb3-4bf6-9b1e-907872456ab1 |
| SCIP notification number (Hungary) | 8e69327f-46d3-4d3e-937a-cc4734bd95c3 |
| SCIP notification number (Italy) | d4d1cefc-62b0-4092-9838-e72a05cfb2df |
| SCIP notification number (Netherlands) | 2f63a4bb-7d52-4087-9cdb-85d03b2defa7 |
| SCIP notification number (Poland) | 403f29a9-bab2-4cc7-a1fa-13daa7af1f17 |
| SCIP notification number (Romania) | bdb7e5dd-9b1d-4ca5-b22f-3b058c47d4f7 |
| SCIP notification number (Sweden) | 97170ea2-76b4-4ba8-9f9a-a9e56636c480 |

Reviews