Fast delivery within 72 Hours
Wago 774-9993/016-301
Cable assembly WINSTA® RD rated current 16 AThe WINSTA® RD cable assembly A coding allows installation of fine-stranded and solid conductors. WAGO pluggable installation connectors can be used when cr…
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Cable assembly WINSTA® RD rated current 16 AThe WINSTA® RD cable assembly A coding allows installation of fine-stranded and solid conductors. WAGO pluggable installation connectors can be used when criteria repeat or are distributed on a specified grid, for example for installing grid lighting or flush-mount lighting. The coding options reduce installation errors, allowing fast, secure wiring of all components. The pluggable installation connector is protected against ingress by solid objects in accordance with protection type IP20 (When mated: IP2xC (These compact connectors are not designed for use in open, easily accessible areas!)). With WINSTA® RD, we have created a product line that fits like a glove into boreholes or conduits thanks to its design. According to the European CPR, the fire class of the cables used for construction is decisive for the safety of buildings as well. For houses with average safety requirements, cable assemblies with fire class E are suitable. Eliminating halogens as an additive in the manufacture of this cable assembly noticeably increases fire safety and minimises environmental pollution.Fast, error-free assembly thanks to cable assemblies from WAGOThe cable is pre-assembled with a socket and a plug. The WINSTA® Pluggable Connection System is ideally tailored to the very strict requirements of building installation. It makes electrical installation pluggable, and consequently faster, more reliable, and error-free. Use of this pre-assembled system decreases time spent on assembly and errors during installation at the construction site. Now you can also cut installation expenses without compromising safety and quality: with protection against mismating eliminates the need for servicing and prevents unnecessary downtime. protection against mismating eliminates errorssaves time, since no wiring is required at the construction sitesuitable for any applicationready for immediate userapid, structured electrical installation
Specification
Notes
| Note | Cables with a different fire class can be found in the eShop. |
|---|
Electrical data - Ratings per IEC/EN
| Ratings per | IEC/EN 60664-1 |
|---|---|
| Nominal voltage (III/3) | 250 V |
| Rated impulse withstand voltage (III / 3) | 4 kV |
| Rated current | 16 A |
| Legend (ratings) | (III / 3) ≙ Overvoltage category III / Pollution degree 3 |
| Ratings per | IEC/EN 60664-1 / IEC/EN 60664-1 / IEC/EN 60664-1 |
| Overvoltage category | III / III / II |
| Pollution degree | 3 / 2 / 2 |
| Nominal voltage | 250 V |
| Rated impulse withstand voltage | 4 kV |
| Rated current | 16 A |
Electrical data - General information
| Note on contact resistance | approx. 1 mΩ of contact resistance approx. 0.25 mΩ contact transition plug/socket |
|---|
Connection data
| Total number of potentials | 3 |
|---|---|
| PE function | Preceding PE contact |
Connection data - Connection 1
| Pole number | 3 |
|---|---|
| Wire cross-section | 1.5 mm² |
| Connection type | Socket - Plug |
Physical data
| Width | 17.5 mm / 0.689 inches |
|---|---|
| Height | 17.5 mm / 0.689 inches |
| Total length | 3 m |
Mechanical data
| Use | General mains applications |
|---|---|
| Variable coding | No |
| Marking | L ⏚ N |
| Mating force of a plug-in connection | approx. 30 … 70 N (depending on pole number) |
| Retention force of a plug-in connection | when locked: > 80N |
| Unmating force of a plug-in connection | Unlocked: approx. 30 … 70 N (depending on pole number) |
| Number of mating cycles | 200, without resistive load |
| Connection type | Socket - Plug |
| Type of pre-assembled cable | Interconnecting cable |
| Cable type | H05Z1Z1-F 3G1.5 |
| Protection type | IP20; When mated: IP2xC (These compact connectors are not designed for use in open, easily accessible areas!) |
Plug-in connection
| Mismating protection | Yes |
|---|---|
| Note on mismating protection | All WINSTA® components are 100% protected against mismating when:a.) plugging different numbers of polesb.) plugging while incorrectly rotated c.) plugging while laterally staggered |
| Locking lever | yes |
| Locking of plug-in connection | locking lever |
Material data
| Note (material data) | Information on material specifications can be found here |
|---|---|
| Color | black |
| Insulation material (main housing) | Polyamide (PA66) |
| Fire class per EN 50575 | Eca |
| Contact material | Copper or copper alloy; surface-treated |
| Contact plating | Tin |
| Fire load | 88.824 MJ |
| Connector color | black |
| Strain relief color | black |
| Sheathed cable color | black |
| Printing color of sheathed cable | white |
| Halogen-free | Yes |
| Silicon-free | Yes |
| Sheath material | Halogen-free |
| Rubber cable | No |
| Weight | 301.9 g |
| Copper weight of the raw cable | 0.043 kg/m |
Environmental requirements
| Processing temperature | -5 … +40 °C |
|---|---|
| Continuous operating temperature | -35 … +85 °C |
| Note on continuous operating temperature | Cable for temperatures ≤ 70 °C (including halogen-free)Insulating parts for temperatures ≤ 105 °C |
Commercial data
| PU (SPU) | 1 pcs |
|---|---|
| Packaging type | unpacked |
| Country of origin | DE |
| GTIN | 4045454320843 |
| Customs tariff number | 85444290900 |
Product Classification
| UNSPSC | 26121629 |
|---|---|
| eCl@ss 10.0 | 27-44-06-04 |
| eCl@ss 9.0 | 27-44-06-04 |
| ETIM 9.0 | EC002587 |
| ETIM 10.0 | EC002587 |
| ECCN | NO US CLASSIFICATION |
Environmental Product Compliance
| RoHS Compliance Status | Compliant,No Exemption |
|---|

Reviews