Fast delivery within 72 Hours
Wago 770-724/009-000
Female connector/socket WINSTA® MIDI with protection against mismatingThe WINSTA® MIDI female connector/socket A coding supports rapid, correct installation. WAGO pluggable installation connectors are…
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Female connector/socket WINSTA® MIDI with protection against mismatingThe WINSTA® MIDI female connector/socket A coding supports rapid, correct installation. WAGO pluggable installation connectors are used when specifications repeat or are distributed on a defined grid, for example for installing grid lighting or flush-mount lighting. For greater protection in electrical installations, the pluggable installation connector is equipped with mechanical protection against mismating. The pluggable installation connector offers protection against contact with live components in accordance with protection type IP20 (When mated: IP2xC (These compact connectors are not designed for use in open, easily accessible areas!)). General mains applications for almost any domain of use can be realised with WINSTA® MIDI pluggable installation connectors with A coding. This pluggable installation connector can be used for electrical currents up to 25 A. Thus the product is especially suitable for high power loads. WINSTA® MIDI with Push-in CAGE CLAMP® spring pressure connection technology is found in can be found in a variety of projects you can use for quick, easy and maximally flexible installation.Lower costs through fast commissioning and elimination of service expenses – solutions from WINSTA® MIDIWINSTA® is the pluggable connection system that is perfectly tailored to the strict requirements of electrical installation. It allows fast, secure and, above all, error-free installation of components and cables. Take advantage of the pluggable version of our maintenance-free spring pressure connection technology too! Plan your installation with with protection against mismating from WAGO. protection against mismating eliminates errorspre-assembled versionswith A coding for use in many general mains applicationscustom-engineered solutionsconvenient installation and commissioning
Specification
Notes
| Note | The snap-in connectors must be relieved of tensile and transverse forces.A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position). |
|---|
Electrical data - Ratings per IEC/EN
| Ratings per | IEC/EN 60664-1 |
|---|---|
| Nominal voltage (III/3) | 400 V |
| Rated impulse withstand voltage (III / 3) | 6 kV |
| Rated current | 25 A |
| Legend (ratings) | (III / 3) ≙ Overvoltage category III / Pollution degree 3 |
| Ratings per | IEC/EN 60664-1 / IEC/EN 60664-1 / IEC/EN 60664-1 |
| Overvoltage category | III / III / II |
| Pollution degree | 3 / 2 / 2 |
| Nominal voltage | 400 V |
| Rated impulse withstand voltage | 6 kV |
| Rated current | 25 A |
Electrical data - Ratings per UL 1977
| Note for the US market | Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 16 A and voltages up to 600 V. For further information, please contact your local sales office. |
|---|---|
| Rated voltage (UL 1977) | 600 V |
| Rated current UL 1977 | 23 A |
| Approvals per | UL 1977 |
| Rated voltage | 600 V |
| Rated current | 23 A |
Electrical data - General information
| Note on contact resistance | approx. 1 mΩ of contact resistance approx. 0.25 mΩ contact transition plug/socket |
|---|
Connection data
| Clamping units | 8 |
|---|---|
| Total number of potentials | 4 |
Connection data - Connection 1
| Connection technology | Push-in CAGE CLAMP® |
|---|---|
| Actuation type | Operating tool, Push-in |
| Nominal cross-section | 4 mm² / 12 AWG |
| Solid conductor | 0.5 … 4 mm² / 20 … 12 AWG |
| Solid conductor; push-in termination | 1.5 … 4 mm² / 16 … 12 AWG |
| Stranded conductor | 0.5 … 2.5 mm² / 20 … 14 AWG |
| Fine-stranded conductor | 0.5 … 4 mm² / 20 … 12 AWG |
| Fine-stranded conductor; with insulated ferrule | 0.25 … 1.5 mm² / 20 … 16 AWG |
| Fine-stranded conductor; with uninsulated ferrule | 0.25 … 2.5 mm² / 20 … 14 AWG |
| Fine-stranded conductor; with ferrule; push-in termination | 1.5 mm² / 16 AWG |
| Strip length | 9 mm / 0.35 inches |
| Pole number | 4 |
| Conductor entry direction to mating direction | 0 ° |
Physical data
| Pin spacing | 10 mm / 0.394 inches |
|---|---|
| Width | 45.5 mm / 1.791 inches |
| Height | 18.5 mm / 0.728 inches |
| Depth | 37.5 mm / 1.476 inches |
Mechanical data
| Use | General mains applications |
|---|---|
| Coding | A |
| Variable coding | Yes |
| Marking | N ⏚ 2/L 1/L' |
| Potential marking | N ⏚ 2/L 1/L' |
| Mating force of a plug-in connection | approx. 20 … 70 N (depending on pole number) |
| Retention force of a plug-in connection | Locked: > 80 N |
| Unmating force of a plug-in connection | Unlocked: approx. 20 … 70 N (depending on pole number) |
| Number of mating cycles | 200, without resistive load |
| Housing sheet thickness | 0.5 … 2 mm / 0.02 … 0.079 inches |
| Design | with protruding interface |
| Mounting type | Snap-in flange |
| Protection type | IP20; When mated: IP2xC (These compact connectors are not designed for use in open, easily accessible areas!) |
Plug-in connection
| Contact type (pluggable connector) | Female connector/socket |
|---|---|
| Connector (connection type) | for conductor |
| Mismating protection | Yes |
| Note on mismating protection | All WINSTA® components are 100% protected against mismating when:a.) plugging different numbers of polesb.) plugging while rotated 180 c.) plugging while laterally staggeredd.) plugging one pole |
| Locking lever | Can be retrofitted |
| Locking of plug-in connection | locking lever |
| Note on locking system | All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug/socket). |
Material data
| Note (material data) | Information on material specifications can be found here |
|---|---|
| Color | white |
| Insulation material (main housing) | Polyamide (PA66) |
| Flammability class per UL94 | V0 |
| Clamping spring material | Chrome-nickel spring steel (CrNi) |
| Contact material | Copper or copper alloy; surface-treated |
| Contact plating | Tin |
| Fire load | 0.24 MJ |
| Weight | 13.5 g |
Environmental requirements
| Processing temperature | -5 … +40 °C |
|---|---|
| Continuous operating temperature | -35 … +85 °C |
| Note on continuous operating temperature | Insulating parts for temperatures ≤ 105 °C |
Commercial data
| PU (SPU) | 100 pcs |
|---|---|
| Packaging type | box |
| Country of origin | DE |
| GTIN | 4045454655099 |
| Customs tariff number | 85366990990 |
Product Classification
| UNSPSC | 39121421 |
|---|---|
| eCl@ss 10.0 | 27-44-06-02 |
| eCl@ss 9.0 | 27-44-06-02 |
| ETIM 9.0 | EC002566 |
| ETIM 10.0 | EC002566 |
| ECCN | NO US CLASSIFICATION |
Environmental Product Compliance
| RoHS Compliance Status | Compliant,No Exemption |
|---|

Reviews
Clear filtersThere are no reviews yet.