Fast delivery within 72 Hours

Wago 770-2313

Male connector/plug WINSTA® MIDI 3-poleFor power and signal transmission: The WINSTA® MIDI male connector/plug P coding. WAGO pluggable installation connectors can be used when specifications repeat o…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Male connector/plug WINSTA® MIDI 3-poleFor power and signal transmission: The WINSTA® MIDI male connector/plug P coding. WAGO pluggable installation connectors can be used when specifications repeat or are distributed on a specified grid, for example for installing grid lighting or flush-mount lighting. The coding options reduce installation errors, allowing fast, secure wiring of all components. The pluggable installation connector is protected in accordance with protection type IP20 (When mated: IP2xC (These compact connectors are not designed for use in open, easily accessible areas!)). This means that users’ fingers will never come into contact with electrified elements. UPS applications for data exchange mostly use the red WINSTA® MIDI pluggable installation connectors with P coding. The rated current and voltage are important criteria for selecting a pluggable installation connector: They provide information about possible domains of use and applications. This product has a current rating of 25 A – therefore it is suitable for high power loads. The WINSTA® MIDI Pluggable Connection System with Push-in CAGE CLAMP® spring pressure connection technology facilitates precise electrification. Due to the integrated test slot, it is possible to check connections even when they are plugged in. That saves time and reduces installation labor and expense.Lower costs through fast commissioning and elimination of service expenses – solutions from WINSTA® MIDIThe WINSTA® Pluggable Connection System allows pluggable electrical installation. This saves time, lowers costs, and reduces the need for servicing. Now you can also lower installation costs without compromising safety and quality: with protection type IP20 reduces the need for servicing and prevents unnecessary downtime. effective protection against mismatingsimple circuitsfor UPS applicationscustom-engineered solutionsquick replacement of defective units during ongoing operation

Specification

Notes

NoteThe snap-in connectors must be relieved of tensile and transverse forces.A surface finish can influence the edge radius of the cutouts. This may affect the snap-in socket fit, so ensure an adequate fit before use. In addition, the punched edge should be on the inside for punched cutouts.The wings of the snap-in connectors must not be mechanically stressed for a long period before use (e.g., due to a pre-locking position).

Electrical data - Ratings per IEC/EN

Ratings perIEC/EN 60664-1
Nominal voltage (III/3)250 V
Rated impulse withstand voltage (III / 3)4 kV
Rated current25 A
Legend (ratings)(III / 3) ≙ Overvoltage category III / Pollution degree 3
Ratings perIEC/EN 60664-1 / IEC/EN 60664-1 / IEC/EN 60664-1
Overvoltage categoryIII / III / II
Pollution degree3 / 2 / 2
Nominal voltage250 V
Rated impulse withstand voltage4 kV
Rated current25 A

Electrical data - Ratings per UL 1977

Note for the US marketSome versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 16 A and voltages up to 600 V. For further information, please contact your local sales office.
Rated voltage (UL 1977)600 V
Rated current UL 197723 A
Approvals perUL 1977
Rated voltage600 V
Rated current23 A

Electrical data - General information

Note on contact resistanceapprox. 1 mΩ of contact resistance approx. 0.25 mΩ contact transition plug/socket

Connection data

Clamping units6
Total number of potentials3
PE functionPreceding PE contact

Connection data - Connection 1

Connection technologyPush-in CAGE CLAMP®
Actuation typeOperating tool, Push-in
Nominal cross-section4 mm² / 12 AWG
Solid conductor0.5 … 4 mm² / 20 … 12 AWG
Solid conductor; push-in termination1.5 … 4 mm² / 16 … 12 AWG
Stranded conductor0.5 … 2.5 mm² / 20 … 14 AWG
Fine-stranded conductor0.5 … 4 mm² / 20 … 12 AWG
Fine-stranded conductor; with insulated ferrule0.25 … 1.5 mm² / 20 … 16 AWG
Fine-stranded conductor; with uninsulated ferrule0.25 … 2.5 mm² / 20 … 14 AWG
Fine-stranded conductor; with ferrule; push-in termination1.5 mm² / 16 AWG
Strip length9 mm / 0.35 inches
Pole number3
Conductor entry direction to mating direction0 °

Physical data

Pin spacing10 mm / 0.394 inches
Width35.5 mm / 1.398 inches
Height17.5 mm / 0.689 inches
Depth41.1 mm / 1.618 inches

Mechanical data

UseEDV (UPS)
CodingP
Variable codingNo
MarkingN ⏚ L
Potential markingN ⏚ L
Mating force of a plug-in connectionapprox. 20 … 70 N (depending on pole number)
Retention force of a plug-in connectionLocked: > 80 N
Unmating force of a plug-in connectionUnlocked: approx. 20 … 70 N (depending on pole number)
Number of mating cycles200, without resistive load
Housing sheet thickness0.5 … 2 mm / 0.02 … 0.079 inches
Mounting typeSnap-in flange
Protection typeIP20; When mated: IP2xC (These compact connectors are not designed for use in open, easily accessible areas!)

Plug-in connection

Contact type (pluggable connector)Male connector/plug
Connector (connection type)for conductor
Mismating protectionYes
Note on mismating protectionAll WINSTA® components are 100% protected against mismating when:a.) plugging different numbers of polesb.) plugging while rotated 180 c.) plugging while laterally staggeredd.) plugging one pole
Locking leveryes
Locking of plug-in connectionlocking lever
Note on locking systemAll connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug/socket).

Material data

Note (material data)Information on material specifications can be found here
Colorred
Insulation material (main housing)Polyamide (PA66)
Flammability class per UL94V0
Clamping spring materialChrome-nickel spring steel (CrNi)
Contact materialCopper or copper alloy; surface-treated
Contact platingTin
Fire load0.258 MJ
Weight11.9 g

Environmental requirements

Processing temperature-5 … +40 °C
Continuous operating temperature-35 … +85 °C
Note on continuous operating temperatureInsulating parts for temperatures ≤ 105 °C

Commercial data

Product Group20 (Winsta)
PU (SPU)100 pcs
Packaging typebox
Country of originPL
GTIN4045454396886
Customs tariff number85366990990

Product Classification

UNSPSC39121402
eCl@ss 10.027-44-06-02
eCl@ss 9.027-44-06-02
ETIM 9.0EC002566
ETIM 10.0EC002566
ECCNNO US CLASSIFICATION

Environmental Product Compliance

RoHS Compliance StatusCompliant,No Exemption

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Wago 770-2313”

Your email address will not be published. Required fields are marked *