Fast delivery within 72 Hours
Wago 770-215
Male connector/plug WINSTA® MIDI rated current 25 AThe WINSTA® MIDI male connector/plug A coding allows installation of solid and fine-stranded conductors. The pluggable installation connectors with s…
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Male connector/plug WINSTA® MIDI rated current 25 AThe WINSTA® MIDI male connector/plug A coding allows installation of solid and fine-stranded conductors. The pluggable installation connectors with spring pressure connection technology work entirely without screw connections. They allow resource-efficient, error-free installation in numerous possible uses. The coding options reduce installation errors, allowing fast, secure wiring of all components. The pluggable installation connector is protected against ingress by solid objects in accordance with protection type IP20 (When mated and secured with a strain relief housing: IP2xC (These compact connectors are not designed for use in open, easily accessible areas!)). General mains applications for almost any domain of use can be realised with WINSTA® MIDI pluggable installation connectors with A coding. This pluggable installation connector can be employed for a voltage load of up to 25 A. As a result, it can also be used for high power loads. Our WINSTA® MIDI product line offers total flexibility for the installation. Through its Push-in CAGE CLAMP® spring pressure connection technology, it guarantees error-free, time-saving installation and offers customization and flexibility for meeting various installation requirements.Lower costs through fast commissioning and elimination of service expenses – solutions from WINSTA® MIDIThe WINSTA® Pluggable Connection System is perfectly tailored to the very strict requirements of building installation. It makes electrical installation pluggable, and thus more efficient, even more reliable, and error-free. Using this pre-assembled system reduces time spent on assembly and errors during installation at the construction site. Now you can also cut installation costs without compromising safety and quality: with marking reduces the need for servicing and prevents unnecessary downtime. protection against mismating eliminates errorspre-assembled versionswith A coding for a great number of applicationsready for immediate usequick replacement of defective units during ongoing operation
Specification
Electrical data - Ratings per IEC/EN
| Ratings per | IEC/EN 60664-1 |
|---|---|
| Nominal voltage (III/3) | 400 V |
| Rated impulse withstand voltage (III / 3) | 6 kV |
| Rated current | 25 A |
| Legend (ratings) | (III / 3) ≙ Overvoltage category III / Pollution degree 3 |
| Ratings per | IEC/EN 60664-1 / IEC/EN 60664-1 / IEC/EN 60664-1 |
| Overvoltage category | III / III / II |
| Pollution degree | 3 / 2 / 2 |
| Nominal voltage | 400 V |
| Rated impulse withstand voltage | 6 kV |
| Rated current | 25 A |
Electrical data - Ratings per UL 1977
| Note for the US market | Some versions may also be used for current interruption in accordance with the UL certificate in select applications with currents below 16 A and voltages up to 600 V. For further information, please contact your local sales office. |
|---|---|
| Rated voltage (UL 1977) | 600 V |
| Rated current UL 1977 | 23 A |
| Approvals per | UL 1977 |
| Rated voltage | 600 V |
| Rated current | 23 A |
Electrical data - General information
| Note on contact resistance | approx. 1 mΩ of contact resistance approx. 0.25 mΩ contact transition plug/socket |
|---|
Connection data
| Clamping units | 10 |
|---|---|
| Total number of potentials | 5 |
| PE function | Preceding PE contact |
Connection data - Connection 1
| Connection technology | Push-in CAGE CLAMP® |
|---|---|
| Actuation type | Operating tool, Push-in |
| Nominal cross-section | 4 mm² / 12 AWG |
| Solid conductor | 0.5 … 4 mm² / 20 … 12 AWG |
| Solid conductor; push-in termination | 1.5 … 4 mm² / 16 … 12 AWG |
| Stranded conductor | 0.5 … 2.5 mm² / 20 … 14 AWG |
| Fine-stranded conductor | 0.5 … 4 mm² / 20 … 12 AWG |
| Fine-stranded conductor; with insulated ferrule | 0.25 … 1.5 mm² / 20 … 16 AWG |
| Fine-stranded conductor; with uninsulated ferrule | 0.25 … 2.5 mm² / 20 … 14 AWG |
| Fine-stranded conductor; with ferrule; push-in termination | 1.5 mm² / 16 AWG |
| Strip length | 9 mm / 0.35 inches |
| Pole number | 5 |
| Conductor entry direction to mating direction | 0 ° |
Physical data
| Pin spacing | 10 mm / 0.394 inches |
|---|---|
| Width | 50 mm / 1.969 inches |
| Height | 12.9 mm / 0.508 inches |
| Depth | 37.5 mm / 1.476 inches |
Mechanical data
| Use | General mains applications |
|---|---|
| Coding | A |
| Variable coding | Yes |
| Marking | L3 L2 L1 ⏚ N |
| Potential marking | L3 L2 L1 ⏚ N |
| Mating force of a plug-in connection | approx. 20 … 70 N (depending on pole number) |
| Retention force of a plug-in connection | Locked: > 80 N |
| Unmating force of a plug-in connection | Unlocked: approx. 20 … 70 N (depending on pole number) |
| Number of mating cycles | 200, without resistive load |
| Protection type | IP20; When mated and secured with a strain relief housing: IP2xC (These compact connectors are not designed for use in open, easily accessible areas!) |
Plug-in connection
| Contact type (pluggable connector) | Male connector/plug |
|---|---|
| Connector (connection type) | for conductor |
| Mismating protection | Yes |
| Note on mismating protection | All WINSTA® components are 100% protected against mismating when:a.) plugging different numbers of polesb.) plugging while rotated 180 c.) plugging while laterally staggeredd.) plugging one pole |
| Locking lever | Can be retrofitted |
| Locking of plug-in connection | locking lever |
| Note on locking system | All connectors for mounted installations (snap-in versions for lighting fixtures or devices, all types of PCB and distribution connectors) are factory-equipped with locking levers to ensure plugs and sockets are securely locked. Additional locking levers are only required for flying leads (plug/socket). |
Material data
| Note (material data) | Information on material specifications can be found here |
|---|---|
| Color | black |
| Cover color | gray |
| Material group | I |
| Insulation material (main housing) | Polyamide (PA66) |
| Flammability class per UL94 | V0 |
| Clamping spring material | Chrome-nickel spring steel (CrNi) |
| Contact material | Copper or copper alloy; surface-treated |
| Contact plating | Tin |
| Fire load | 0.331 MJ |
| Weight | 16.8 g |
Environmental requirements
| Processing temperature | -5 … +40 °C |
|---|---|
| Continuous operating temperature | -35 … +85 °C |
| Note on continuous operating temperature | Insulating parts for temperatures ≤ 105 °C |
Commercial data
| Product Group | 20 (Winsta) |
|---|---|
| PU (SPU) | 50 pcs |
| Packaging type | box |
| Country of origin | PL |
| GTIN | 4044918254557 |
| Customs tariff number | 85366990990 |
Product Classification
| UNSPSC | 39121402 |
|---|---|
| eCl@ss 10.0 | 27-44-06-05 |
| eCl@ss 9.0 | 27-44-06-05 |
| ETIM 9.0 | EC002560 |
| ETIM 10.0 | EC002560 |
| ECCN | NO US CLASSIFICATION |
Environmental Product Compliance
| RoHS Compliance Status | Compliant,No Exemption |
|---|

Reviews
Clear filtersThere are no reviews yet.