Fast delivery within 72 Hours

Wago 750-606

This supply module powers all intrinsically safe 750 Series Ex i Modules. It also monitors the power supply to the downstream Ex i segment and electrically isolates the intrinsically safe from the non…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

This supply module powers all intrinsically safe 750 Series Ex i Modules. It also monitors the power supply to the downstream Ex i segment and electrically isolates the intrinsically safe from the non-intrinsically safe section of the WAGO I/O System 750. The input and output sides are electrically isolated from each other.The maximum output current provided by the supply module is 1.0 A. When configuring the Ex i segment, the total current must not be exceeded.In the event of a short circuit or overload, electronic monitoring automatically disables the output voltage. Once the fault has been cleared, the output voltage is reactivated after approximately 10 seconds.Note:If more than one supply module is required per station due to load conditions, four spacer modules (750-616) must be used to ensure proper separation between the intrinsically safe Ex i segments.Indicators:Green LED (input voltage)Green/red LED (output voltage available/not available)

Specification

Notes

NoteGeneral information on explosion protection, including installation regulations, can be found in the WAGO I/O System 750/753 manuals!

Technical data

Item descriptionPower Supply; 24 VDC; Diagnostics
Supply voltage24 VDC; (−25 % … +30 %); input voltage
Fuseelectronic
Intrinsically safe Ex iYes
DiagnosticsInput voltage failure, fuse triggered
Data width2-bit diagnostics
Supply voltage (system)5 VDC; via data contacts
Current consumption (5 V system supply)7.5 mA
Supply voltage (field)24 VDC (-25 … +30 %); (Adjacent Ex i modules are supplied with Uo = max. 26.8 V); via power jumper contacts (power supply via CAGE CLAMP® connection; distribution via spring contact)
Power consumption P<sub>max.</sub>29 W
Power loss P<sub>l</sub>< 5 W
Number of outgoing power jumper contacts2
Current carrying capacity (power jumper contacts)1 A
IndicatorsLED (A) green: operating voltage status: input; LED (B) green/red: operating voltage status: output

Explosion protection

IdentificationATEX: II 3 (1) G Ex ec [ia Ga] IIC T4 Gc; II (1) D [Ex ia Da] IIIC; I (M1) [Ex ia Ma] I, IECEx/INMETRO: Ex ec [ia Ga] IIC T4 Gc; [Ex ia Da] IIIC; [Ex ia Ma] I, cULus (Zone classified): AEx nA IIC T4 Gc; Ex nA IIC T4 Gc X, cULus (Devision classified): Class I, Div. 2, Group A B C D, T4
Ex standardEN IEC 60079-0, -7, -11
Power supply (output)Uo = 26.8 V (safe voltage per IEC 60079-11, protection level ia); Un = 24 V ± 0.3 V, In = 1 A
Power supply (input)Un = 24 VDC (−25 … +30 %); Pmax = 29 W; Um = 253 VAC

Connection data

Connectable conductor materialsCopper
Connection typeField supply
Solid conductor0.08 … 1.5 mm² / 28 … 14 AWG
Fine-stranded conductor0.08 … 1.5 mm² / 28 … 14 AWG
Strip length5 … 6 mm / 0.2 … 0.24 inches
Connection technology: field supply2 x CAGE CLAMP®

Physical data

Width48 mm / 1.89 inches
Height100 mm / 3.937 inches
Depth70.9 mm / 2.791 inches
Depth from upper-edge of DIN-rail63.7 mm / 2.508 inches

Mechanical data

Mounting typeDIN-35 rail

Material data

Housing materialPolycarbonate; polyamide 6.6
Fire load1.913 MJ
Weight167.5 g
Conformity markingCE

Environmental requirements

Ambient temperature (operation)0 … +55 °C
Ambient temperature (storage)-25 … +85 °C
Protection typeIP20
Pollution degree2 per IEC 61131-2
Operating altitude0 … 2000 m / 0 … 6562 ft
Mounting positionHorizontal left, horizontal right, horizontal top, horizontal bottom, vertical top and vertical bottom
Relative humidity (without condensation)95 %
Vibration resistance4g per IEC 60068-2-6
Shock resistance15g per IEC 60068-2-27
EMC immunity to interferenceper EN 61000-6-2, marine applications
EMC emission of interferenceper EN 61000-6-3, marine applications
Exposure to pollutantsper IEC 60068-2-42 and IEC 60068-2-43
Permissible H<sub>2</sub>S contaminant concentration at a relative humidity <lt/> 75 %10 ppm
Permissible SO<sub>2</sub> contaminant concentration at a relative humidity <lt/> 75 %25 ppm

Commercial data

Product Group15 (I/O System)
PU (SPU)1 pcs
Packaging typeBox
Country of originDE
GTIN4045454961909
Customs tariff number85389091890

Product Classification

UNSPSC39121004
eCl@ss 10.027-24-26-10
eCl@ss 9.027-24-26-10
ETIM 9.0EC001600
ETIM 10.0EC001600
ECCNNO US CLASSIFICATION

Environmental Product Compliance

RoHS Compliance StatusCompliant,No Exemption
SCIP notification number (Austria)c0e961b9-f5ee-4b65-a1a8-472aee7a2b4c
SCIP notification number (Belgium)9a9fbad1-2151-4ca2-aec5-25ab8f123037
SCIP notification number (Bulgaria)ed072b21-fb78-4134-9934-dfa4a6dc0ef4
SCIP notification number (Czech Republic)266c66db-8acb-4f00-bf69-094ee6553caa
SCIP notification number (Denmark)350710b9-e9a4-4603-aaf5-169b93ff0e77
SCIP notification number (Finland)8ff26ff3-9f09-4bb8-aedc-18be5f80fba7
SCIP notification number (France)8535d1d5-e475-4e2e-a292-5ec098a62a8b
SCIP notification number (Germany)8624e861-a34f-472f-901f-a8b55966be77
SCIP notification number (Hungary)a933bfdc-ce3e-40d2-95cd-93c13d3796c4
SCIP notification number (Italy)f9a05418-8ba1-4d38-9d5d-9faba4db04de
SCIP notification number (Netherlands)9e17eb72-481a-4d00-bf13-7abd58508e22
SCIP notification number (Poland)25b955c9-d2f8-4744-b703-a5b0acbd030b
SCIP notification number (Romania)737c4cd0-1a61-4064-827d-49007a2f8b50
SCIP notification number (Sweden)a8f2598e-8225-4e57-84ed-8ccaa13ba2aa