Fast delivery within 72 Hours

Wago 750-494

The 750-494 3-Phase Power Measurement Module measures electrical data in a three-phase supply network. The voltage is measured via network connection to clamping points L1, L2, L3 and N. The current o…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

The 750-494 3-Phase Power Measurement Module measures electrical data in a three-phase supply network. The voltage is measured via network connection to clamping points L1, L2, L3 and N. The current of the three phases is fed to IL1, IL2, IL3, and IN via current transformers. The 3-phase power measurement module transmits all metrics (e.g., reactive/apparent/effective power, energy consumption, power factor, phase angle, frequency, over-/undervoltage) directly to the process image, without requiring high computing power from the controller. Both comprehensive metrics and harmonic analysis up to the 41st harmonic permit extensive network analysis via the fieldbus. These metrics enable the operator to optimize supply to a drive or machine, protecting the system from damage and failure. The four-quadrant display indicates the load type (inductive, capacitive) and whether it is an energy consumer or producer.

Specification

Technical data

Number of measurement inputs6 (3 voltage measurement inputs, 3 current measurement inputs)
Signal typePower measurement
Input voltage (max.)Current Inputs: 18 VAC
Signal formAny periodic signals (considering the threshold frequencies)
Resolution [bit]24 Bit
Data width2 x 128-bit data; 2 x 64-bit control/status
Voltage path input resistance (typ.)1072 kΩ
Current path input resistance (typ.)22 mΩ
Reference for measurement errorAC current/voltage
Measurement error (reference temperature)25 °C
Measurement error, deviation (max.) from the upper-range value0.5 %
Measurement current (max.)1 A
Measurement cycle timeAdjustable for the arithmetic mean value, min./max. values
Frequency range (mains frequency)45 … 65 Hz
Frequency range (harmonics analysis)0 … 3300 Hz
Limit frequency15.9 kHz
Rated voltageULN = 277 VAC; ULL = 480 VAC
Calculated valuesLine-to-line voltage, power output, energy, power factors, mains frequency, harmonic analysis (up to the 41st harmonic), THD
Measurement componentsEvaluating
Measurement methodTrue RMS measurement
Configuration optionsWAGO-I/O-CHECK, CODESYS Library, e!COCKPIT
Supply voltage (system)5 VDC; via data contacts
Current consumption (5 V system supply)100 mA
Isolation4 kV system/field
Rated impulse withstand voltage4 kV
IndicatorsLED (A) green: Communication; LED (B-G) red: Error L1, Override in Current Measurement Path (display), Undervoltage in Voltage Measurement Path (display), Error L2, Error L3, Override in Voltage Measurement Path (display); LED (H) yellow: Interchange in Phase Sequence L1-L2-L3

Connection data

Connection technology: I/O8 x CAGE CLAMP®
Connectable conductor materialsCopper
Connection typeInputs/outputs
Solid conductor0.08 … 2.5 mm² / 28 … 14 AWG
Fine-stranded conductor0.08 … 2.5 mm² / 28 … 14 AWG
Strip length8 … 9 mm / 0.31 … 0.35 inches

Physical data

Width12 mm / 0.472 inches
Height100 mm / 3.937 inches
Depth67.8 mm / 2.669 inches
Depth from upper-edge of DIN-rail60.6 mm / 2.386 inches

Mechanical data

Mounting typeDIN-35 rail

Material data

Colorlight gray
Housing materialPolycarbonate; polyamide 6.6
Fire load0.704 MJ
Weight49.6 g
Conformity markingCE

Environmental requirements

Ambient temperature (operation)0 … +55 °C
Ambient temperature (storage)-40 … +85 °C
Protection typeIP20
Pollution degree2
Operating altitude0 … 2000 m / 0 … 6562 ft
Mounting positionHorizontal left, horizontal right, horizontal top, horizontal bottom, vertical top and vertical bottom
Relative humidity (without condensation)95 %
Vibration resistance4g per IEC 60068-2-6
Shock resistance15g per IEC 60068-2-27
EMC immunity to interferenceper EN 61000-6-2
EMC emission of interferenceper EN 61000-6-3
Exposure to pollutantsper IEC 60068-2-42 and IEC 60068-2-43
Permissible H<sub>2</sub>S contaminant concentration at a relative humidity <lt/> 75 %10 ppm
Permissible SO<sub>2</sub> contaminant concentration at a relative humidity <lt/> 75 %25 ppm

Commercial data

Product Group15 (I/O System)
PU (SPU)1 pcs
Packaging typeBox
Country of originDE
GTIN4050821548232
Customs tariff number85389099990

Product Classification

UNSPSC41113630
eCl@ss 10.027-24-26-05
eCl@ss 9.027-24-26-05
ETIM 9.0EC001596
ETIM 10.0EC001596
ECCNNO US CLASSIFICATION

Environmental Product Compliance

CAS-No.1303-86-2, 1317-36-8, 7439-92-1
REACH Candidate List SubstanceDiboron trioxide, Lead, Lead monoxide
RoHS Compliance StatusCompliant,With Exemption
RoHS Exemption6(c), 7(a), 7(c)-I, 7(c)-II
SCIP notification number (Austria)6751fb20-e77f-42f9-8909-ff11e9fc8990
SCIP notification number (Belgium)56eb9410-401e-49a8-b2b6-4649bdd9a5b1
SCIP notification number (Bulgaria)8dea98db-3e6b-497b-89b3-906410e9f55d
SCIP notification number (Czech Republic)d4b46b93-65de-4e96-a18c-b9e4f3e427fb
SCIP notification number (Denmark)373321ab-036e-4d53-a5cf-312fac46e55b
SCIP notification number (Finland)bcc5f37c-7820-452a-a569-53ad8314950d
SCIP notification number (France)d71a6c73-2878-4a10-9a68-1c6598010ac4
SCIP notification number (Germany)887005a7-e5b5-4faf-8895-9b97b481b884
SCIP notification number (Hungary)d86d6665-3f25-4730-891e-e650f2789d5e
SCIP notification number (Italy)60fac85f-f397-4122-b43e-21d65be01e79
SCIP notification number (Netherlands)fdb296f1-9fad-4839-9ce0-af9489c9f744
SCIP notification number (Poland)01a8255e-4e30-43f9-9574-9addf52d1931
SCIP notification number (Romania)616c9896-c53c-48e3-a0f6-493b97ccb7b8
SCIP notification number (Sweden)dde8ce05-89f9-4677-bb05-948fc7426253

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Wago 750-494”

Your email address will not be published. Required fields are marked *