Fast delivery within 72 Hours

Wago 750-493/000-001

The 3-phase power measurement module measures electrical data in a three-phase supply network.The voltage is measured via network connection to clamping points L1, L2, L3 and N.The current of the thre…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

The 3-phase power measurement module measures electrical data in a three-phase supply network.The voltage is measured via network connection to clamping points L1, L2, L3 and N.The current of the three phases is fed to IL1, IL2, IL3, and IN via current transformers.The 3-phase power measurement module transmits the root mean square values into the process image without requiring high computing power from the controller. For each phase, the effective power (P) and the energy consumption (W) are calculated by the 3-phase power measurement module using the root mean square values for all measured voltages (V) and currents (I). For example, both the apparent power (S) and phase shift angle (φ) can be easily derived from these values.Therefore, the 3-phase power measurement module provides comprehensive network analysis via fieldbus. Metrics, such as effective and apparent power consumption or load condition, enable the operator to optimize supply to a drive or machine. This can protect the installation from damage and failure.

Specification

Technical data

Number of measurement inputs6 (3 voltage measurement inputs, 3 current measurement inputs)
Signal typePower measurement
Input voltage (max.)Current Inputs: 18 VAC
Signal formAny (taking the maximum frequency into account)
Resolution [bit]16 Bit
Data width2 x 48-bit data; 2 x 24-bit control/status (optional)
Voltage path input resistance (typ.)1071 kΩ
Current path input resistance (typ.)5 mΩ
Reference for measurement errorAC current/voltage
Measurement error (reference temperature)25 °C
Measurement error, deviation (max.) from the upper-range value0.5 %
Measurement current (max.)5 A
Measurement cycle timeAdjustable measuring cycle time for Min_Max_Values
Frequency range with activated DC filter10 … 2000 Hz
Frequency range with deactivated DC filter0 … 2000 Hz
Frequency range (mains frequency)45 … 65 Hz
Limit frequency7.2 kHz
Rated voltageULN = 277 VAC; ULL = 480 VAC
Calculated valuesActive power, active energy, grid frequency, cos ϕ
Measurement componentsEvaluating
Measurement methodTrue RMS measurement
Configuration optionsWAGO-I/O-CHECK, CODESYS Library, e!COCKPIT
Supply voltage (system)5 VDC; via data contacts
Current consumption (5 V system supply)100 mA
Isolation4 kV system/field
Rated impulse withstand voltage4 kV
IndicatorsLED (A) green: Communication; LED (B-G) red: Error L1, Override in Current Measurement Path (display), Undervoltage in Voltage Measurement Path (display), Error L2, Error L3, Override in Voltage Measurement Path (display); LED (H) yellow: Interchange in Phase Sequence L1-L2-L3

Connection data

Connection technology: I/O8 x CAGE CLAMP®
Connectable conductor materialsCopper
Connection typeInputs/outputs
Solid conductor0.08 … 2.5 mm² / 28 … 14 AWG
Fine-stranded conductor0.08 … 2.5 mm² / 28 … 14 AWG
Strip length8 … 9 mm / 0.31 … 0.35 inches

Physical data

Width12 mm / 0.472 inches
Height100 mm / 3.937 inches
Depth67.8 mm / 2.669 inches
Depth from upper-edge of DIN-rail60.6 mm / 2.386 inches

Mechanical data

Mounting typeDIN-35 rail

Material data

Colorlight gray
Housing materialPolycarbonate; polyamide 6.6
Fire load0.704 MJ
Weight48 g
Conformity markingCE

Environmental requirements

Ambient temperature (operation)0 … +55 °C
Ambient temperature (storage)-40 … +85 °C
Protection typeIP20
Pollution degree2 per IEC 61131-2
Operating altitude0 … 2000 m / 0 … 6562 ft
Mounting positionHorizontal left, horizontal right, horizontal top, horizontal bottom, vertical top and vertical bottom
Relative humidity (without condensation)95 %
Vibration resistancePer IEC 60068-2-6
Shock resistance15g per IEC 60068-2-27
EMC immunity to interferenceper EN 61000-6-2
EMC emission of interferenceper EN 61000-6-3
Exposure to pollutantsper IEC 60068-2-42 and IEC 60068-2-43
Permissible H<sub>2</sub>S contaminant concentration at a relative humidity <lt/> 75 %10 ppm
Permissible SO<sub>2</sub> contaminant concentration at a relative humidity <lt/> 75 %25 ppm

Commercial data

PU (SPU)1 pcs
Packaging typeBox
Country of originDE
GTIN4055143374422
Customs tariff number85389099990

Product Classification

UNSPSC41113630
eCl@ss 10.027-24-26-05
eCl@ss 9.027-24-26-05
ETIM 9.0EC001596
ETIM 10.0EC001596
ECCNNO US CLASSIFICATION

Environmental Product Compliance

CAS-No.1303-86-2, 1317-36-8, 7439-92-1
REACH Candidate List SubstanceDiboron trioxide, Lead, Lead monoxide
RoHS Compliance StatusCompliant,With Exemption
RoHS Exemption6(c), 7(a), 7(c)-I, 7(c)-II
SCIP notification number (Bulgaria)e3e85262-907a-4597-ae48-32a09b67dbb7