Fast delivery within 72 Hours
Wago 750-464/040-000
This analog input module directly connects to Pt or Ni resistance sensors and potentiometers.It can be operated as a 2-channel (2- and 3-wire) or 4-channel (2-wire) module.The module automatically lin…
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
This analog input module directly connects to Pt or Ni resistance sensors and potentiometers.It can be operated as a 2-channel (2- and 3-wire) or 4-channel (2-wire) module.The module automatically linearizes the entire temperature range. A sensor error (short circuit, line break or measurement range overflow) is indicated by a red LED.The module can be configured via WAGO‐I/O‐CHECK or GSD files.It features multiple setting options and high accuracy. The device is ideal for operation in extreme environments thanks to:An extended temperature rangeGreater immunity to impulse voltages and electromagnetic interferenceHigher vibration and shock resistance
Specification
Technical data
| Number of analog inputs | 4 |
|---|---|
| Total number of channels (module) | 4 |
| Signal type | Resistance measurement, Potentiometer positions |
| Signal type (configurable) | Yes |
| Sensor connection | 4 x (2-wire); 2 x (3-wire) |
| Data width | 4 (2) x 16-bit data; 4 (2) x 8-bit control/status (optional) |
| Resolution (over entire range) | 0.1 °C |
| Conversion time (typ.) | 320 ms |
| Measurement error (25 °C) | ≤ 1 K over entire temperature range, ≤ 0.5 K over limited temperature range (−30 °C … +120 °C) |
| Temperature coefficient | ≤ 20 ppm/K; typ. ≤ 15 ppm/K |
| Accuracy (+25 °C) | ≤ ± 0.2 % of full scale value; typ.: ≤ ± 0.1 % of full scale value |
| Measuring current (typ.) | ≤ 350 µA per measurement circuit |
| Measurement repetition rate (standard) | 1.1 s |
| Measurement repetition rate (2-channel/2-conductor) | 0.63 s |
| Response time (max.) | 4 s |
| Sensor types | Pt100; Configurable: Pt200, Pt500, Pt1000 (IEC 751), Ni100, Ni1000 (DIN 43760), Ni120 (Minco), Ni1000 (TK 5000), Potentiometer (2-channel operation only): 10R … 1k2, 10R … 5k0 |
| Temperature range | −200 … +850 °C (Pt), −60 … +300 °C (Ni 100, Ni 1000), −60 … +250 °C (Ni 1000 TK5000), −80 … +260 °C (Ni 120) |
| Supply voltage (system) | 5 VDC; via data contacts |
| Current consumption (5 V system supply) | 50 mA |
| Supply voltage (field) | 24 VDC (-25 … +30 %); via power jumper contacts (power supply via blade contact; transmission via spring contact); Derating must be observed! |
| Dielectric strength | 510 VAC / 775 VDC; per EN 60870-2-1 |
| Rated impulse withstand voltage | 1 kV |
| Indicators | LED (A, E, B, F) green: Function AI 1 … AI 4; LED (C, G, D, H) red: Error AI 1 … AI 4 |
| Number of incoming power jumper contacts | 2 |
| Number of outgoing power jumper contacts | 2 |
| Current carrying capacity (power jumper contacts) | 10 A |
| Derating | Derating (supply voltage):Ambient temperatures under laboratory conditions: (-25 … +30 %);for -40 … +55 °C: 24 V (-25 … +20 %);for +55 … +70 °C: 24 V (-25 … +10 %);Lower limit in all temperature ranges: -27.5 % (including 15 % residual ripple) |
Connection data
| Connection technology: I/O | 8 x CAGE CLAMP® |
|---|---|
| Connectable conductor materials | Copper |
| Connection type | Inputs/outputs |
| Solid conductor | 0.25 … 2.5 mm² / 24 … 14 AWG |
| Fine-stranded conductor | 0.25 … 2.5 mm² / 24 … 14 AWG |
| Strip length | 8 … 9 mm / 0.31 … 0.35 inches |
Physical data
| Width | 12 mm / 0.472 inches |
|---|---|
| Height | 100 mm / 3.937 inches |
| Depth | 67.8 mm / 2.669 inches |
| Depth from upper-edge of DIN-rail | 60.6 mm / 2.386 inches |
Mechanical data
| Mounting type | DIN-35 rail |
|---|
Material data
| Color | dark gray |
|---|---|
| Housing material | Polycarbonate; polyamide 6.6 |
| Fire load | 0.945 MJ |
| Weight | 49.2 g |
| Conformity marking | CE |
Environmental requirements
| Ambient temperature (operation) | -40 … +70 °C |
|---|---|
| Ambient temperature (installation) | -20 … +70 °C |
| Ambient temperature (storage) | -40 … +85 °C |
| Protection type | IP20 |
| Pollution degree | 2 per IEC 61131-2 |
| Operating altitude | Without temperature derating: 0 … 2000 m; with temperature derating: 2000 … 5000 m (0.5 K/100 m); 5000 m (max.) |
| Mounting position | Horizontal left, horizontal up, vertical top and vertical bottom |
| Relative humidity (without condensation) | 95 % |
| Relative humidity (with condensation) | Short-term condensation per Class 3K7/IEC EN 60721-3-3 and E-DIN 40046-721-3 (except for wind-driven precipitation, water and ice formation) |
| Vibration resistance | According to type test for marine classification (ABS, BV, DNV, IACS, LR): acceleration: 5g, IEC 60068-2-6, EN 60870-2-2, IEC 60721-3-1, -3, EN 50155, EN 61373 |
| Shock resistance | per IEC 60068-2-27 (10g/16 ms/half-sine/1,000 shocks; 25g/6 ms/half-sine/1,000 shocks), EN 50155, EN 61373 |
| EMC immunity to interference | per EN 61000-6-1, -2; EN 61131-2; marine applications; EN 50121-3-2; EN 50121-4, -5; EN 60255-26; EN 60870-2-1; EN 61850-3; IEC 61000-6-5; IEEE 1613; VDEW: 1994 |
| EMC emission of interference | Per EN 61000-6-3, -4, EN 61131-2, EN 60255-26, marine applications, EN 60870-2-1, EN 61850-3, EN 50121-3-2, EN 50121-4, -5 |
| Exposure to pollutants | Per IEC 60068-2-42 and IEC 60068-2-43 |
| Permissible H<sub>2</sub>S contaminant concentration at a relative humidity <lt/> 75 % | 10 ppm |
| Permissible SO<sub>2</sub> contaminant concentration at a relative humidity <lt/> 75 % | 25 ppm |
Commercial data
| Product Group | 15 (I/O System) |
|---|---|
| PU (SPU) | 1 pcs |
| Packaging type | box |
| Country of origin | DE |
| GTIN | 4050821460329 |
| Customs tariff number | 85389099990 |
Product Classification
| UNSPSC | 32151705 |
|---|---|
| eCl@ss 10.0 | 27-24-26-01 |
| eCl@ss 9.0 | 27-24-26-01 |
| ETIM 9.0 | EC001596 |
| ETIM 10.0 | EC001596 |
| ECCN | NO US CLASSIFICATION |
Environmental Product Compliance
| CAS-No. | 11120-22-2, 1303-86-2, 1317-36-8, 7439-92-1 |
|---|---|
| REACH Candidate List Substance | Diboron trioxide, Lead, Lead monoxide, Lead silicate, Perfluorobutane sulfonic acid (PFBS) and its salts |
| RoHS Compliance Status | Compliant,With Exemption |
| RoHS Exemption | 6(c), 7(a), 7(c)-I, 7(c)-II |
| SCIP notification number (Austria) | bab220f3-b49b-441a-8fd7-48e5982bcd23 |
| SCIP notification number (Belgium) | a161140f-3c02-4860-8be3-4a918e3e9c76 |
| SCIP notification number (Bulgaria) | d91bb5a7-aed1-4363-a08e-c172555b75e5 |
| SCIP notification number (Czech Republic) | e4a9f6a4-6f7a-4061-ae2d-3ffdcfa87f5e |
| SCIP notification number (Denmark) | 97ac303c-0b68-4a0a-b773-1e0b597ba505 |
| SCIP notification number (Finland) | bc8a2508-d83f-494a-9b77-891c17d679d9 |
| SCIP notification number (France) | 92c6ffd5-683f-47c9-9303-04f1eb11d07e |
| SCIP notification number (Germany) | 4cafb702-c987-4248-97f9-958392ef1696 |
| SCIP notification number (Hungary) | acceee52-5fff-42ed-8c7a-5dd17ddcc41f |
| SCIP notification number (Italy) | 716885ac-4b76-49bb-b148-de234d459afb |
| SCIP notification number (Netherlands) | 97a7ba7b-1381-468f-aad2-ef48b5efe4f1 |
| SCIP notification number (Poland) | 46ac5db4-0c81-48de-83e4-8ba05ad159b2 |
| SCIP notification number (Romania) | ff97a74b-3b6e-4da5-ad3c-ea4c8bfff58c |
| SCIP notification number (Sweden) | 54824380-7890-40fd-8ea7-ca890161656d |

Reviews
Clear filtersThere are no reviews yet.