Fast delivery within 72 Hours
Wago 750-439/040-000
This digital input module records binary signals from sensors operating in Zone 0+1 hazardous areas, permitting channel-by-channel short circuit and wire-break diagnostics. NAMUR sensors, optocouplers…
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
This digital input module records binary signals from sensors operating in Zone 0+1 hazardous areas, permitting channel-by-channel short circuit and wire-break diagnostics. NAMUR sensors, optocouplers, mechanical contacts (LED diagnostics can be turned off via control byte) or other actuating elements can be connected via intrinsically safe devices.The WAGO I/O System 750 XTR must be installed either in Zone 2 or in a non-hazardous area. Each sensor is supplied with a short-circuit-protected voltage of 8.2 V.Indicators:Green LED (signal ON)Red LED (short circuit)Red flashing LED (wire-break)Field and system levels are electrically isolated.The device is ideal for operation in extreme environments thanks to:An extended temperature rangeGreater immunity to impulse voltages and electromagnetic interferenceHigher vibration and shock resistance
Specification
Notes
| Note | The digital input module must only be operated via 24 VDC Ex i XTR power supply (750-606/040-000)!General information on explosion protection, including installation regulations, can be found in the WAGO I/O System 750 XTR manuals! |
|---|
Technical data
| Item description | 8-Channel Digital Input; NAMUR; Intrinsically safe |
|---|---|
| Number of digital inputs | 8 |
| Total number of channels (module) | 8 |
| Signal type | NAMUR |
| Signal current (0) NAMUR | ≤1.2 mA |
| Signal current (1) NAMUR | ≥2.1 mA |
| Sensor connection | 8 x (2-wire) |
| Input characteristic | high-side switching |
| Input filter | 3 ms |
| Sensor supply | 8.2 VDC |
| Input pulse separation | ≥3 ms |
| Open-circuit voltage | 8.2 V |
| Short-circuit current | ≤ 8.2 mA (± 0.2 mA) |
| Switching hysteresis | 0.2 mA |
| Input resistance | 1,000 Ω |
| Intrinsically safe Ex i | Yes |
| Diagnostics | Short circuit, wire break |
| Input data width (internal) max. | 16 Bit |
| Output data width (internal) max. | 16 Bit |
| Supply voltage (system) | 5 VDC; via data contacts |
| Current consumption (5 V system supply) | 56 mA |
| Supply voltage (field) | 24 VDC; (Ex i XTR power supply: Uo = max. 26.8 ); via power jumper contacts (supply via blade contact; distribution via spring contact) |
| Current consumption, field supply (module with no external load) | 11 mA |
| Power consumption P<sub>max.</sub> | 1.2 W |
| Power loss P<sub>l</sub> | 0.54 W |
| Isolation | 300 VAC system/supply |
| Rated impulse withstand voltage | 1 kV; Rated surge voltage between intrinsically safe and non-intrinsically safe circuits: 1.5 kV (EN 60079-11) |
| Number of incoming power jumper contacts | 2 |
| Number of outgoing power jumper contacts | 2 |
| Current carrying capacity (power jumper contacts) | 1 A |
| Indicators | LED (A-H) green/red: Status/error DI 1 … DI 8 |
Explosion protection
| Identification | ATEX: II 3 (1) G Ex ec [ia Ga] IIC T4 Gc; II (1) D [Ex ia Da] IIIC; I (M1) [Ex ia Ma] I, IECEx/INMETRO: Ex ec [ia Ga] IIC T4 Gc; [Ex ia Da] IIIC; [Ex ia Ma] I, cULus (Devision classified): Class I, Div. 2, Group A B C D, T4 |
|---|---|
| Ex standard | EN/IEC 60079-0, -7, -11 |
| Safety-relevant data (circuit) | Uo = 11.76 V; Io = 12.48 mA; Po = 36.67 mW; linear characteristic curve |
| Reactances Ex ia IIC | Lo = 100 mH; Co = 1.5 µF |
| Reactances Ex ia IIB | Lo = 100 mH; Co = 9.9 µF |
| Reactances Ex ia IIA | Lo = 100 mH; Co = 39 µF |
| Reactances Ex ia I | Lo = 100 mH; Co = 38 µF |
| Reactances (note) | Reactances without accounting for the concurrence of capacitance (Co) and inductance (Lo) |
Connection data
| Connection technology: I/O | 16 x CAGE CLAMP® |
|---|---|
| Connectable conductor materials | Copper |
| Connection type | Inputs/outputs |
| Solid conductor | 0.25 … 2.5 mm² / 24 … 14 AWG |
| Fine-stranded conductor | 0.25 … 2.5 mm² / 24 … 14 AWG |
| Strip length | 8 … 9 mm / 0.31 … 0.35 inches |
Physical data
| Width | 24 mm / 0.945 inches |
|---|---|
| Height | 100 mm / 3.937 inches |
| Depth | 67.8 mm / 2.669 inches |
| Depth from upper-edge of DIN-rail | 60.6 mm / 2.386 inches |
Mechanical data
| Mounting type | DIN-35 rail |
|---|
Material data
| Color | blue |
|---|---|
| Housing material | Polycarbonate; polyamide 6.6 |
| Fire load | 1.975 MJ |
| Weight | 93.8 g |
| Conformity marking | CE |
Environmental requirements
| Ambient temperature (operation) | -40 … +70 °C |
|---|---|
| Ambient temperature (storage) | -40 … +85 °C |
| Ambient temperature (installation) | -20 … +70 °C |
| Protection type | IP20 |
| Pollution degree | 2 per IEC 61131-2 |
| Operating altitude | without temperature derating: 0 … 2000 m; with temperature derating: 2000 … 5000 m (0.5 K/100 m); 5000 m (max.) |
| Mounting position | Horizontal left, horizontal up, vertical top and vertical bottom |
| Relative humidity (without condensation) | 95 % |
| Relative humidity (with condensation) | Short-term condensation per Class 3K7/IEC EN 60721-3-3 and E-DIN 40046-721-3 (except for wind-driven precipitation, water and ice formation) |
| Vibration resistance | Per IEC 60068-2-6 (acceleration: 5g), EN 60870-2-2, IEC 60721-3-1, -3 |
| Shock resistance | per IEC 60068-2-27 (15g/11 ms/half-sine/1,000 shocks; 25g/6 ms/1,000 shocks), EN 61373 |
| EMC immunity to interference | per EN 61000-6-1, -2, EN 61131-2, marine applications, EN 60255-26, EN 60870-2-1, EN 61850-3, IEC 61000-6-5, IEEE 1613, VDEW: 1994 |
| EMC emission of interference | per EN 61000-6-3, -4, EN 61131-2, EN 60255-26, marine applications, EN 60870-2-1, EN 61850-3 |
| Exposure to pollutants | per IEC 60068-2-42 and IEC 60068-2-43 |
| Permissible H<sub>2</sub>S contaminant concentration at a relative humidity <lt/> 75 % | 10 ppm |
| Permissible SO<sub>2</sub> contaminant concentration at a relative humidity <lt/> 75 % | 25 ppm |
Commercial data
| PU (SPU) | 1 pcs |
|---|---|
| Packaging type | Box |
| Country of origin | DE |
| GTIN | 4055143649438 |
| Customs tariff number | 85389099990 |
Product Classification
| UNSPSC | 32151705 |
|---|---|
| eCl@ss 10.0 | 27-24-26-04 |
| eCl@ss 9.0 | 27-24-26-04 |
| ETIM 9.0 | EC001599 |
| ETIM 10.0 | EC001599 |
| ECCN | NO US CLASSIFICATION |
Environmental Product Compliance
| CAS-No. | 1303-86-2, 1317-36-8, 7439-92-1 |
|---|---|
| REACH Candidate List Substance | Diboron trioxide, Lead, Lead monoxide, Perfluorobutane sulfonic acid (PFBS) and its salts |
| RoHS Compliance Status | Compliant,With Exemption |
| RoHS Exemption | 6(c), 7(a), 7(c)-I, 7(c)-II |
| SCIP notification number (Austria) | 4b25589e-1a1f-4e4f-8aa5-ae53fcc796c8 |
| SCIP notification number (Belgium) | 754f4b36-3019-4307-81b2-e8dc6dcbb7bc |
| SCIP notification number (Bulgaria) | 906f2450-7508-4d2a-87e8-b51778bc0927 |
| SCIP notification number (Czech Republic) | 77d8c957-822e-4359-b662-8e7185fbf900 |
| SCIP notification number (Denmark) | f3cdf71f-986a-424b-a9a1-53e3ae1e5de8 |
| SCIP notification number (Finland) | 14553aa8-65d3-4d17-88ab-f1c2bc41e68c |
| SCIP notification number (France) | fc4853d8-7dfa-4d21-9061-d01358e49185 |
| SCIP notification number (Germany) | 44c64c42-b9e3-4ea1-b3c1-c8939e5132b1 |
| SCIP notification number (Hungary) | 31674adb-3080-4686-9480-57a5616fd7ca |
| SCIP notification number (Italy) | d01fd5d7-b59c-405e-8f8d-efcfd53f9de5 |
| SCIP notification number (Netherlands) | 525622d2-fa17-438e-8093-4c9f6ef5250a |
| SCIP notification number (Poland) | 4a12c42e-c306-42dc-a319-777279d7d0bb |
| SCIP notification number (Romania) | 808a02ba-32de-4866-9df1-08beb0ca094b |
| SCIP notification number (Sweden) | 9ebbee69-5b9c-4b70-b1bf-ed78693a9462 |

Reviews