Wago 750-377
This fieldbus coupler connects the WAGO I/O System 750 to PROFINET IO (open, real-time Industrial ETHERNET automation standard). The coupler identifies the connected I/O modules and creates local proc…
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
This fieldbus coupler connects the WAGO I/O System 750 to PROFINET IO (open, real-time Industrial ETHERNET automation standard). The coupler identifies the connected I/O modules and creates local process images for one I/O controller and one I/O supervisor according to preset configurations. This process image may include a mixed arrangement of analog (word-by-word data transfer) or complex modules and digital (bit-by-bit data transfer) modules. The fieldbus coupler operates as an I/O device in the network. It features an integrated 2-port switch, simplifying the creation of a line structure without additional network components.The device name can be assigned via DCP protocol or a default name can be instantiated via DIP switch.
Specification
Technical data
| Communications | PROFINET IO |
|---|---|
| Device-specific | Supported profiles: PROFIsafe V2, PROFIenergy V1.0; ID code: Vendor ID: 0x011D; Device ID: 0x02EE; Module ID: 0x01000177 (firmware version 01, 02), 0x02000177 (from firmware version 03) |
| PROFINET IO features | Integrierter 2-Port-Switch; Autonegotiation; Auto-MDIX; isochrone Echtzeitkommunikation; Sendetakt: 1 ms (RT); 1, 2, 4 ms (IRT); Gerätetausch ohne Programmiergerät |
| Transmission rate | 10/100 Mbit/s (10 Mbit/s (ETHERNET protocols), 100 Mbit/s full duplex (PROFINET IO)) |
| Bus segment length (max.) | 100 m |
| Transmission medium (communication/fieldbus) | Twisted pair S-UTP; 100 Ω; Cat. 5 |
| Number of modules per node (max.) | 64 |
| Number of modules without a bus extension (max.) | 64 |
| Input and output process image (fieldbus) max. | 256 bytes/256 bytes |
| Supply voltage (system) | 24 VDC (-25 … +30 %); via pluggable connector |
| Current consumption (5 V system supply) | 450 mA |
| Total current (system supply) | 700 mA |
| Input current (typ.) at nominal load (24 V) | 280 mA |
| Power supply efficiency (typ.) at nominal load (24 V) | 90 % |
| Isolation | 500 V system/field |
Connection data
| Connection technology: communication/fieldbus | PROFINET IO: 2 x RJ-45 |
|---|---|
| Connection technology: system supply | 2 x CAGE CLAMP® |
| Connectable conductor materials | Copper |
| Connection type | System supply |
| Solid conductor | 0.08 … 1.5 mm² / 28 … 14 AWG |
| Fine-stranded conductor | 0.08 … 1.5 mm² / 28 … 14 AWG |
| Strip length | 5 … 6 mm / 0.2 … 0.24 inches |
| Connection technology: device configuration | 1 x Male connector; 4-pole |
Physical data
| Width | 49.5 mm / 1.949 inches |
|---|---|
| Height | 96.8 mm / 3.811 inches |
| Depth | 71.9 mm / 2.831 inches |
| Depth from upper-edge of DIN-rail | 64.7 mm / 2.547 inches |
Mechanical data
| Mounting type | DIN-35 rail |
|---|
Material data
| Color | light gray |
|---|---|
| Housing material | Polycarbonate; polyamide 6.6 |
| Fire load | 1.045 MJ |
| Weight | 107.1 g |
| Conformity marking | CE |
Environmental requirements
| Ambient temperature (operation) | 0 … +55 °C |
|---|---|
| Ambient temperature (storage) | -25 … +85 °C |
| Protection type | IP20 |
| Pollution degree | 2 per IEC 61131-2 |
| Operating altitude | 0 … 2000 m / 0 … 6562 ft |
| Mounting position | Horizontal left, horizontal right, horizontal top, horizontal bottom, vertical top and vertical bottom |
| Relative humidity (without condensation) | 95 % |
| Vibration resistance | 4g per IEC 60068-2-6 |
| Shock resistance | 15g per IEC 60068-2-27 |
| EMC immunity to interference | per EN 61000-6-2, marine applications |
| EMC emission of interference | per EN 61000-6-3, marine applications |
| Exposure to pollutants | per IEC 60068-2-42 and IEC 60068-2-43 |
| Permissible H<sub>2</sub>S contaminant concentration at a relative humidity <lt/> 75 % | 10 ppm |
| Permissible SO<sub>2</sub> contaminant concentration at a relative humidity <lt/> 75 % | 25 ppm |
Commercial data
| Product Group | 15 (I/O System) |
|---|---|
| PU (SPU) | 1 pcs |
| Packaging type | Box |
| Country of origin | DE |
| GTIN | 4050821687443 |
| Customs tariff number | 85176200000 |
Product Classification
| UNSPSC | 32151705 |
|---|---|
| eCl@ss 10.0 | 27-24-26-07 |
| eCl@ss 9.0 | 27-24-26-07 |
| ETIM 9.0 | EC001603 |
| ETIM 10.0 | EC001603 |
| ECCN | NO US CLASSIFICATION |
Environmental Product Compliance
| CAS-No. | 1303-86-2, 1317-36-8, 693-98-1, 7439-92-1 |
|---|---|
| REACH Candidate List Substance | 2-methylimidazole, Diboron trioxide, Lead, Lead monoxide |
| RoHS Compliance Status | Compliant,With Exemption |
| RoHS Exemption | 6(c), 7(a), 7(c)-I, 7(c)-II |
| SCIP notification number (Austria) | 8e50993b-352f-4caf-b004-7e9bce6f15bb |
| SCIP notification number (Belgium) | a14f6ab6-06ac-4c61-98a2-5c189db49153 |
| SCIP notification number (Bulgaria) | 2a37af0c-f34d-4aed-afec-3f07e855fd3a |
| SCIP notification number (Czech Republic) | 4533a93d-d469-4c73-8f02-f71b1d908549 |
| SCIP notification number (Denmark) | d80e9460-6e10-4c56-9fe2-521065092b5a |
| SCIP notification number (Finland) | a863a644-f00a-44c2-8803-845c28ed6d3a |
| SCIP notification number (France) | d2bd405c-a678-4596-9082-85dc4e946173 |
| SCIP notification number (Germany) | 92183a6e-26ea-470d-aff7-cc025a1b5463 |
| SCIP notification number (Hungary) | b146cca2-9aec-44c2-9ab9-34650969996e |
| SCIP notification number (Italy) | c2952b09-a026-4fb2-bdc1-29d0d10f0151 |
| SCIP notification number (Netherlands) | 1184562c-de93-4a45-ad62-0783d6050495 |
| SCIP notification number (Poland) | 566db317-8dbc-4015-b228-7d4e34300976 |
| SCIP notification number (Romania) | b746bece-b994-46d0-be97-e360b08af70e |
| SCIP notification number (Sweden) | 8583835a-b794-43b9-92a9-38cb252241c7 |