Fast delivery within 72 Hours

Wago 750-338/040-000

This fieldbus coupler connects the WAGO I/O System as a slave to the CANopen fieldbus. Data is transmitted via PDOs and SDOs.The fieldbus coupler detects all connected I/O modules and creates a local…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

This fieldbus coupler connects the WAGO I/O System as a slave to the CANopen fieldbus. Data is transmitted via PDOs and SDOs.The fieldbus coupler detects all connected I/O modules and creates a local process image. Analog and specialty module data is sent via words and/or bytes, digital data is sent bit by bit.The local process image is divided into two data zones containing the data received and the data to be sent. The process data can be sent via the CANopen bus to a control system for further processing. The process output data is sent via the CANopen bus.The data of the analog modules is stored in the PDOs according to the order in which the modules are connected to the coupler. The bits of the digital modules are sent byte by byte and also mapped in the PDOs. If the amount of digital I/O information exceeds eight bits, the coupler automatically starts with a new byte.All entries of the object directory can be mapped as required in the 32 Rx PDOs and 32 Tx PDOs. The complete input and output process image can be transmitted via SDOs.Spacer modules can be set via software.The device is ideal for operation in extreme environments thanks to:An extended temperature rangeGreater immunity to impulse voltages and electromagnetic interferenceHigher vibration and shock resistance

Specification

Notes

NoteNote: Configuration files required (EDS)!

Technical data

CommunicationsCANopen
Number of fieldbus nodes on master (max.)110
Transmission rate10 kBd … 1 MBd
Bus segment length (max.)1000 m
Transmission medium (communication/fieldbus)Shielded Cu cable 3 x 0.25 mm²
Number of modules per node (max.)64
Number of modules without a bus extension (max.)64
Other CANopen featuresNMT slave, Minimum boot-up, Variable PDO mapping, Emergency message, Life guarding, Empty module configuration
Number of PDOs32 Tx / 32 Rx
Number of SDOs2 SDO servers
COB ID distributionSDO, standard
Node ID distributionDIP switch
Communication profileDS-301 V4.1
Device profileDS-401 V2.0, Limit value monitoring, Edge-triggered PDOs, Configurable response in the event of an error
Input and output process image (fieldbus) max.512 bytes/512 bytes
Supply voltage (system)24 VDC; via pluggable connector (CAGE CLAMP® connection); Derating must be observed!
Current consumption (5 V system supply)350 mA
Total current (system supply)1,650 mA
Supply voltage (field)24 VDC; Power supply via pluggable connector (CAGE CLAMP® connection); Transmission via power jumper contacts; Derating must be observed!
Input current (typ.) at nominal load (24 V)500 mA
Power supply efficiency (typ.) at nominal load (24 V)90 %
Number of outgoing power jumper contacts2
Current carrying capacity (power jumper contacts)10 A
Rated impulse withstand voltage1 kV
Ratings perIEC/EN 60664-1
DeratingDerating (supply voltage):Ambient temperatures under laboratory conditions: (-25 … +30 %);for -40 … +55 °C: 24 V (-25 … +20 %);for +55 … +70 °C: 24 V (-25 … +10 %);Lower limit in all temperature ranges: -27.5 % (including 15 % residual ripple)

Connection data

Connection technology: communication/fieldbusCANopen: 1 x D-sub 9 plug
Connection technology: field supply4 x CAGE CLAMP®
Connection technology: system supply2 x CAGE CLAMP®
Connectable conductor materialsCopper
Connection typeSystem/field supply
Solid conductor0.25 … 2.5 mm² / 24 … 14 AWG
Fine-stranded conductor0.25 … 2.5 mm² / 24 … 14 AWG
Strip length8 … 9 mm / 0.31 … 0.35 inches
Connection technology: device configuration1 x Male connector; 4-pole

Physical data

Width50.5 mm / 1.988 inches
Height100 mm / 3.937 inches
Depth71.1 mm / 2.799 inches
Depth from upper-edge of DIN-rail63.9 mm / 2.516 inches

Mechanical data

Mounting typeDIN-35 rail

Material data

Housing materialPolycarbonate; polyamide 6.6
Fire load2.166 MJ
Weight176.5 g
Conformity markingCE

Environmental requirements

Ambient temperature (operation)-40 … +70 °C
Ambient temperature (storage)-40 … +85 °C
Ambient temperature (installation)-20 … +70 °C
Protection typeIP20
Pollution degree2 per IEC 61131-2
Operating altitudewithout temperature derating: 0 … 2000 m; with temperature derating: 2000 … 5000 m (0.5 K/100 m); 5000 m (max.)
Mounting positionHorizontal left, horizontal up, vertical top and vertical bottom
Relative humidity (without condensation)95 %
Relative humidity (with condensation)Short-term condensation per Class 3K7/IEC EN 60721-3-3 and E-DIN 40046-721-3 (except for wind-driven precipitation, water and ice formation)
Vibration resistanceAccording to type test for marine classification (ABS, BV, DNV, IACS, LR): acceleration: 5g, IEC 60068-2-6, EN 60870-2-2, IEC 60721-3-1, -3, EN 50155, EN 61373
Shock resistanceper IEC 60068-2-27 (10g/16 ms/half-sine/1,000 shocks; 25g/6 ms/half-sine/1,000 shocks), EN 50155, EN 61373
EMC immunity to interferenceper EN 61000-6-1, -2, EN 61131-2, marine applications, EN 50121-3-2, -4, -5, EN 60255-26
EMC emission of interferenceper EN 61000-6-3, -4, EN 61131-2, EN 60255-26, marine applications, EN 60870-2-1, EN 61850-3, EN 50121-3-2, EN 50121-4, -5
Exposure to pollutantsper IEC 60068-2-42 and IEC 60068-2-43
Permissible H<sub>2</sub>S contaminant concentration at a relative humidity <lt/> 75 %10 ppm
Permissible SO<sub>2</sub> contaminant concentration at a relative humidity <lt/> 75 %25 ppm

Commercial data

Product Group15 (I/O System)
PU (SPU)1 pcs
Packaging typeBox
Country of originDE
GTIN4050821460145
Customs tariff number85176200000

Product Classification

UNSPSC32151705
eCl@ss 10.027-24-26-07
eCl@ss 9.027-24-26-07
ETIM 9.0EC001603
ETIM 10.0EC001603
ECCNNO US CLASSIFICATION

Environmental Product Compliance

CAS-No.1303-86-2, 1317-36-8, 7439-92-1, 79-94-7, 1303-86-2, 1317-36-8, 7439-92-1
REACH Candidate List Substance2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol, Diboron trioxide, Lead, Lead monoxide, Perfluorobutane sulfonic acid (PFBS) and its salts, Diboron trioxide, Lead, Lead monoxide, Perfluorobutane sulfonic acid (PFBS) and its salts
RoHS Compliance StatusCompliant,With Exemption
RoHS Exemption6(c), 7(a), 7(c)-I, 7(c)-II, 6(c), 7(a), 7(c)-I, 7(c)-II
SCIP notification number (Austria)81a21ba6-08c7-4694-a15e-b16000d7fccd
SCIP notification number (Belgium)b3d96990-dbed-44a7-9acb-7e7b6fe64314
SCIP notification number (Bulgaria)b4e7ee55-ea12-4ba7-9745-8888af8e1177
SCIP notification number (Czech Republic)ab0ffa1e-8bd0-486e-9f96-888a73abf80d
SCIP notification number (Denmark)d739ba71-cf22-406c-8370-46a3573781bb
SCIP notification number (Finland)09629630-5663-42f9-a617-9d2840ac9b9c
SCIP notification number (France)33e7d9e8-8167-4a38-b9f2-9759de3103fe
SCIP notification number (Germany)a66ab265-ac02-4ce8-8e90-ed3f3c4f7017
SCIP notification number (Hungary)c04421ac-f0b7-4009-80db-e7f65e343dbb
SCIP notification number (Italy)91558b2d-1823-4810-873c-6922e2a5c695
SCIP notification number (Netherlands)23058bd8-1880-4d53-823d-4d6db7a70131
SCIP notification number (Poland)3ed6dc64-30e1-4fd6-b612-8b4e47efa9a4
SCIP notification number (Romania)ad2c4fa2-f929-4a80-8982-1906e7990abc
SCIP notification number (Sweden)27170e24-a743-4e39-88e3-0fdd3ff94dd9

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.