Wago 285-154

High-current terminal block, 285 Series, power cage clampOur through terminal block (item number 285-154) makes connections quick and easy. Conductors can only be connected to this through terminal bl…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

High-current terminal block, 285 Series, power cage clampOur through terminal block (item number 285-154) makes connections quick and easy. Conductors can only be connected to this through terminal block if their strip length is 32 mm . This product features conductor terminals and utilizes POWER CAGE CLAMP. The POWER CAGE CLAMP is perfect for connecting large conductor cross-sections. This universal connector is both reliable and maintenance-free. What’s more, you can use it to connect all types of conductors and the clamping point can be locked open, making it easier to use. You do not need to use a torque wrench or prepare the conductor. For example, crimping ferrules is not necessary. This through terminal block is suitable for conductor cross sections ranging from 10 mm² to 50 mm².

Specification

Electrical data - Ratings per IEC/EN

Ratings perIEC/EN 60947-7-1
Nominal voltage (III/3)1000 V
Rated impulse withstand voltage (III / 3)8 kV
Rated current150 A
Legend (ratings)(III / 3) ≙ Overvoltage category III / Pollution degree 3
Ratings perIEC/EN 60947-7-1 / IEC/EN 60947-7-1 / IEC/EN 60947-7-1
Overvoltage categoryIII / III / II
Pollution degree3 / 2 / 2
Nominal voltage1000 V
Rated impulse withstand voltage8 kV
Rated current150 A

Electrical data - Ratings per UL

Approvals perUL 1059
Rated voltage UL (Use Group B)600 V
Rated current UL (Use Group B)150 A
Rated voltage UL (Use Group C)600 V
Rated current UL (Use Group C)150 A
Approvals perUL 1059 / UL 1059 / UL 1059
Use groupB / C / D
Rated voltage600 V / 600 V
Rated current150 A / 150 A

Electrical data - Ratings per CSA

Approvals perCSA 22.2 No 158
Rated voltage CSA (Use Group B)600 V
Rated current CSA (Use Group B)150 A
Rated voltage CSA (Use Group C)600 V
Rated current CSA (Use Group D)150 A
Approvals perCSA 22.2 No 158 / CSA 22.2 No 158 / CSA 22.2 No 158
Use groupB / C / D
Rated voltage600 V / 600 V
Rated current150 A

Electrical data - Power Loss

Power loss, per pole (potential)4.725 W
Rated current I<sub>N</sub> for power loss specification150 A
Resistance value for specified, current-dependent power loss0 Ω

Electrical data - General information

Wiring directionSide-entry wiring

Connection data

Clamping units2
Total number of potentials1
Number of levels1
Number of jumper slots2

Connection data - Connection 1

Connection technologyPOWER CAGE CLAMP
Actuation typeT-wrench; 8 mm
Connectable conductor materialsCopper
Nominal cross-section50 mm²
Solid conductor10 … 50 mm² / 8 … 1/0 AWG
Stranded conductor10 … 50 mm² / 8 … 1/0 AWG
Fine-stranded conductor10 … 70 mm² / 8 … 2/0 AWG
Fine-stranded conductor; with insulated ferrule10 … 50 mm² / 8 … 1/0 AWG
Fine-stranded conductor; with uninsulated ferrule10 … 50 mm² / 8 … 1/0 AWG
Strip length32 mm / 1.26 inches
Wiring directionSide-entry wiring

Physical data

Width20 mm / 0.787 inches
Height94 mm / 3.701 inches
Depth from upper-edge of DIN-rail87 mm / 3.425 inches

Mechanical data

Mounting typeDIN-35 x 15 rail, DIN-rail 35 x 15
Mounting (note)only suitable for DIN 35 x 15 rail
Marking levelSide marking

Material data

Note (material data)Information on material specifications can be found here
Colorblue
Material groupI
Insulation material (main housing)Polyamide (PA66)
Flammability class per UL94V0
Fire load1.798 MJ
Weight158.7 g

Environmental requirements

Processing temperature-35 … +85 °C
Continuous operating temperature-60 … +105 °C

Environmental requirements - Environmental Testing

Test specification: <br/>Railway applications –<br/>Rolling stock –<br/>Electronic equipmentDIN EN 50155 (VDE 0115-200):2022-06
Test procedure: <br/>Railway applications – <br/>Rolling stock equipment – <br/>Vibration and shock testsDIN EN 61373 (VDE 0115-0106):2011-04
Spectrum/Mounting locationService life test, Category 1, Class A/B
Functional test with noise-like oscillationsTest passed according to Section 8 of the standard
Frequencyf1 = 5 Hz to f2 = 150 Hz
Acceleration0.101g (highest test level used for all axes)
Test duration per axis10 min.
Test directionsX, Y and Z axes
Monitoring of contact faults and interruptionsPassed
Voltage drop measurement before and after each axisPassed
Simulated service life test through increased levels of noise-like oscillationsTest passed according to Section 9 of the standard
Frequencyf1 = 5 Hz to f2 = 150 Hz
Acceleration0.572g (highest test level used for all axes)
Test duration per axis5 h
Test directionsX, Y and Z axes
Extended testing: Monitoring of contact faults and interruptionsPassed
Extended testing: Voltage drop measurement before and after each axisPassed
Shock testTest passed according to Section 10 of the standard
Shock pulse formHalf sine
Acceleration5g (highest test level used for all axes)
Shock duration30 ms
Number of shocks (per axis)3 pos. und 3 neg.
Test directionsX, Y and Z axes
Extended testing: Monitoring of contact faults and interruptionsPassed
Extended testing: Voltage drop measurement before and after each axisPassed
Vibration and shock stress for rolling stock equipmentPassed

Commercial data

Product Group1 (Rail Mounted Terminal Blocks)
PU (SPU)5 pcs
Packaging typebox
Country of originPL
GTIN4045454507428
Customs tariff number85369010000

Product Classification

UNSPSC39121410
eCl@ss 10.027-14-11-20
eCl@ss 9.027-14-11-20
ETIM 9.0EC000897
ETIM 10.0EC000897
ECCNNO US CLASSIFICATION

Environmental Product Compliance

RoHS Compliance StatusCompliant,No Exemption

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Wago 285-154”

Your email address will not be published. Required fields are marked *