Fast delivery within 72 Hours

B&R X90RO440.04-S1

9 to 32 VDC4 safe relay outputsOutput type “Relay”Nominal output current 2x 2 A and 2x 4 ANormally open contactSingle-channel isolated outputsX2X LinkThe relay option board provides 4 additional safe…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

9 to 32 VDC4 safe relay outputsOutput type “Relay”Nominal output current 2x 2 A and 2x 4 ANormally open contactSingle-channel isolated outputsX2X LinkThe relay option board provides 4 additional safe relay outputs. Communication to the mainboard is made possible via X2X Link. The modules can be used for controlling floating actuators in safety-related applications up to PL e or SIL 3. Safety relays are installed within the module. The positively driven feedback contacts are evaluated within the module. The safe digital output modules have a start interlock on error in the event of network errors.

Specification

I/O module4 relays with 1 normally open contact each, 9 to 32 VDC / 2 and 4 A
B&R ID code0xFB3D
Automation Studio4.7 or later
Automation Runtime4.7 or later
Mapp Technology Packagemapp Safety 5.12 and later:
Status indicators
Module run/errorYes, using software
OutputsYes, using software
Power consumptionMax. 2 W
Max. I/O cycle time1 ms
Bus0.26 W
Internal I/O1.65 W
Additional power dissipation caused by actuators (resistive) [W]+3.2
UN ECE-R10Yes
CEYes
UKCAYes
CRA (Cyber Resilience Act)In preparation
MTTFD per channel100 years if the relay channel is used individually, 390 years if 2 relay channels are connected in series
Mission timeMax. 20 years
Module<2.7*10-7 if the relay channel is used individually, <5.4*10-9 if 2 relay channels are connected in series
OpenSAFETY wiredNegligible
OpenSAFETY wireless<1*10-14 * Number of openSAFETY packets per hour
PFD per channel<5.6*10-4 if the relay channel is used individually, <1*10-4 if 2 relay channels are connected in series
Proof test interval (PT)20 years
CategoryKAT 1 if the relay channel is used individually, KAT 4 if 2 relay channels are connected in series
PLPL c if the relay channel is used individually, PL e if 2 relay channels are connected in series
DC1, 24 VDC2 A / 1,800,000 4 A / 1,000,000
DC13, 24 VDC2 A / 121,400 4 A / 120,000
SIL CLSIL 1 if the relay channel is used individually, SIL 3 if 2 relay channels are connected in series
Voltage range9 to 32 VDC
Quantity4
VariantRelay / Normally open contact, internal high-side and low-side control
Nominal output currentRelays 1 and 2: 2 A Relays 3 and 4: 4 A
Diagnostic statusContact position determined by positively driven contacts
Max. switching frequency10 Hz
0 → 1<50 ms
1 → 0<20 ms
MechanicalMin. 1 x 107 ops.
ElectricalMin. 1 x 105 ops. (at 4 A / 32 VDC)
Internal
ExternalRelays 1 and 2: External fuse 2 A Relays 3 and 4: External fuse 4 A
Contact resistance (without terminal block)80 mΩ
Contact service lifeSee “Contact service life”.
Switching voltage range5 to 32 VDC
Switching current range1 mA to 4 A
Max. inrush current20 A for 25 ms, max. 1x per minute
Overvoltage category per EN 60664-1II
DC1Relays 1 and 2: 24 VDC / 2 A Relays 3 and 4: 24 VDC / 4 A
DC13Relays 1 and 2: 24 VDC / 2 A Relays 3 and 4: 24 VDC / 4 A
Electrical isolationChannel isolated from channel and bus
AnyYes
Degree of protection per EN 60529IP66, IP69K
Horizontal mounting orientation-40 to 75°C housing surface
Vertical mounting orientation-40 to 75°C housing surface
Storage5 to 100%, condensing
Transport5 to 100%, condensing
Operation5 to 100%, condensing
Width47 mm
Length95 mm

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “B&R X90RO440.04-S1”

Your email address will not be published. Required fields are marked *