B&R X90PO210.08-00

9 to 32 VDC8 PWM outputs4 A per channelCurrent measurementCentral cutoffX2X LinkThe PWM option board offers 8 additional analog outputs that can also be used as digital inputs/outputs. Communication t…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

9 to 32 VDC8 PWM outputs4 A per channelCurrent measurementCentral cutoffX2X LinkThe PWM option board offers 8 additional analog outputs that can also be used as digital inputs/outputs. Communication to the mainboard is implemented using X2X Link. In addition, the PWM option board provides current measurement for each channel.

Specification

I/O module8 digital inputs/outputs 9 to 32 VDC for 1-wire connections
B&R ID code0xEBC2
Status indicators
Diagnostic outputsIn the application using current measurement
Power consumption0.91 W
Digital - DigitalNo
UN ECE-R10Yes
CEYes
UKCAYes
CRA (Cyber Resilience Act)In preparation
Quantity0 to 8, depends on the use of multifunction inputs/outputs
Functions4 A nominal current / channel PWM frequency 15 Hz to 1 kHz, digital input/output, sink/source circuit – configurable per channel, configurable software input filter, configurable switch-on/switch-off ramp, integrated output protection
Input voltage9 to 32 VDC
Input current at 24 VDCTyp. 2.7 mA
Input circuitSink/Source, configurable
Hardware100 µs
SoftwareDefault 1 ms, configurable between 0 and 25 ms in 0.1 ms increments
Input resistanceTyp. 9 kΩ
Switching threshold45% supply voltage
Nominal voltage12/24 VDC
Supply voltage (permissible range)9 to 32 VDC
Nominal current4 A
Summation current16 A
PWM frequency15 Hz to 1 kHz
Duty cycle0 to 100% in 0.1% steps, resolution <50 μs
Output circuitSink/Source
Output protectionThermal shutdown in the event of overcurrent or short circuit, integrated protection for switching inductive loads
VariantCurrent-sourcing/Current-sinking FET
Diagnostic statusOutput monitoring with 1 ms delay
Leakage current when the output is switched offMax. 50 µA
Residual voltage<0.1 V at 4 A nominal current
Peak short-circuit current50 A (max. 0.2 ms)
Current measurement range±10 A
Conversion time40 μs
Resolution12-bit (6 mA)
Data typeINT 0x8001 to 0x7FFF
Current1 LSB = 305 μA
Accuracy±0.5% ±50 mA
Temperature drift±0.02%/°C ±1 mA/°C
Common mode error±3 mA/V
AnyYes
Degree of protection per EN 60529Up to IP69K
Horizontal mounting orientation-40 to 85°C housing surface
Vertical mounting orientation-40 to 85°C housing surface
Storage5 to 100%, condensing
Transport5 to 100%, condensing
Operation5 to 100%, condensing
Width47 mm
Length95 mm