POWERLINK8 digital channels, configurable as inputs or outputsI/O configuration and firmware update via the fieldbusIntegrated connection to the local expansion via X2X Link for up to 250 additional m…

3 in stock

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

POWERLINK8 digital channels, configurable as inputs or outputsI/O configuration and firmware update via the fieldbusIntegrated connection to the local expansion via X2X Link for up to 250 additional modulesConfigurable I/O cycle

The bus controller makes it possible to connect X2X Link I/O nodes to POWERLINK. It is also possible to operate the X2X Link cycle synchronously 1:1 or synchronous to POWERLINK using a prescaler. Additional X2X Link I/O nodes (X67 modules or other modules based on X2X Link) can be connected using the integrated X2X Link connection. Mechanically, POWERLINK is connected via an IP67-rated standard D-coded M12 Ethernet connector.POWERLINK is a standard protocol for Fast Ethernet equipped with hard real-time characteristics. The POWERLINK Standardization Group (EPSG) ensures that the standard remains open and is continually developed:: www.ethernet-powerlink.org.

Specification

Bus controller0x1E37
Inputs/Outputs8x M8, 3-pin
Insulation voltage between channel and bus860 Veff
Nominal voltage24 VDC
Internal I/O module0x1311
Sensor/Actuator power supplyMax. 12 W
Status indicatorsI/O function per channel, supply voltage, bus function
OutputsYes, using LED status indicator and software
I/O power supplyM8, 4-pin
Dynamic node allocation (DNA)Yes
Fieldbus200 μs
Power output3 W X2X Link power supply for I/O modules
Internal I/O2.5 W
CEYes
UKCAYes
CRA (Cyber Resilience Act)In preparation
ATEXZone 2, II 3G Ex nA IIA T5 Gc IP67, Ta = 0 – Max. 60°C TÜV 05 ATEX 7201X
ULcULus E115267 Industrial control equipment
HazLoccCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5
KCYes
TypeType 2
VariantCurrent-sourcing FET
Line lengthMax. 100 m between 2 stations (segment length)
Transfer rate100 Mbit/s
Physical layer100BASE-TX
Half-duplexYes
Full-duplexNo
AutonegotiationYes
Auto-MDI/MDIXYes
Synchronization between bus systems possibleYes
Voltage range18 to 30 VDC
Integrated protective functionReverse polarity protection
VoltageI/O power supply minus voltage drop for short-circuit protection
Voltage drop for short-circuit protection at 0.5 AMax. 2 VDC
Summation currentMax. 0.5 A
Short-circuit proofYes
Input characteristics per EN 61131-2Type 1
Input voltage18 to 30 VDC
Input current at 24 VDCTyp. 4 mA
Input circuitSink
Hardware≤10 μs (channels 1 to 4) / ≤70 µs (channels 5 to 8)
SoftwareDefault 0 ms, configurable between 0 and 25 ms in 0.2 ms intervals
Input resistanceTyp. 6 kΩ
Additional functions50 kHz event counting, gate measurement
Low<5 VDC
High>15 VDC
Quantity1
Signal formSquare wave pulse
EvaluationPositive edge – Negative edge
Input frequencyMax. 50 kHz
Counter 1Input 1
Counter 2Input 3
Counter frequencyMax. 50 kHz
Counter size16-bit
Internal48 MHz, 3 MHz, 187.5 kHz
Length of pause between pulses≥100 µs
Pulse length≥20 µs
Supported inputsInput 2 or input 4
Switching voltageI/O power supply minus residual voltage
Nominal output current0.5 A
Total nominal current4 A
Output circuitSource
Output protectionThermal shutdown in the event of overcurrent or short circuit, integrated protection for switching inductive loads, reverse polarity protection of the output power supply
Diagnostic statusOutput monitoring with 10 ms delay
Leakage current when the output is switched off5 µA
Switching on after overload shutdownApprox. 10 ms (depends on the module temperature)
Residual voltage<0.3 V at 0.5 A nominal current
Peak short-circuit current<12 A
0 → 1<400 µs
1 → 0<400 µs
Resistive loadMax. 100 Hz
Inductive loadSee section “Switching inductive loads”.
Braking voltage when switching off inductive loads50 VDC
Electrical isolationBus isolated from POWERLINK and channel Channel not isolated from channel
AnyYes
Installation elevation above sea levelMax. 4000 m (no limitations)
Degree of protection per EN 60529IP67
Operation-25 to 60°C
Derating
Storage-40 to 85°C
Transport-40 to 85°C
Width53 mm
Height85 mm
Depth42 mm
Weight195 g
M8Max. 0.4 Nm
M12Max. 0.6 Nm