B&R X67BC81RT.L12

POWERLINKreACTION Technology moduleIntegrated hub for efficient cabling4 digital inputs5 digital channels, configurable as inputs or outputs2 analog inputs ±10 V1 analog input ±10 V1 ABR incremental e…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

POWERLINKreACTION Technology moduleIntegrated hub for efficient cabling4 digital inputs5 digital channels, configurable as inputs or outputs2 analog inputs ±10 V1 analog input ±10 V1 ABR incremental encoder input 5 V5 V and 24 V encoder power supply integrated in the encoder connectorI/O configuration and firmware update via the fieldbusIntegrated connection to local expansions via X2X Link for 250 additional modulesCycle time configurable starting at 200 µs for local expansions

The bus controller makes it possible to connect X2X Link I/O nodes to POWERLINK. It is also possible to operate the X2X Link cycle synchronously 1:1 or synchronous to POWERLINK using a prescaler. Additional X2X Link I/O nodes (X67 modules or other modules based on X2X Link) can be connected using the integrated X2X Link connection. Mechanically, POWERLINK is connected via an IP67-rated standard D-coded M12 Ethernet connector.POWERLINK is a standard protocol for Fast Ethernet equipped with hard real-time characteristics. The POWERLINK Standardization Group (EPSG) ensures that the standard remains open and is continually developed:: www.ethernet-powerlink.org.Ultrafast reACTION Technology makes it possible to control I/O channels with response times down to 1 μs. All of the commands that can be used for reACTION programs are provided as function blocks in special libraries (e.g. AsIORTI). Programming using the standard Function Block Diagram (FBD) editor in Automation Studio is compliant with IEC 61131-3.

Specification

Bus controller0xE2DC
Inputs/OutputsM12, 5-pin, A-coded
Insulation voltage between channel and bus500 Veff, 1 min
Nominal voltage24 VDC
Internal I/O module0xE2DF
Status indicatorsI/O function per channel, supply voltage, bus function
OutputsYes, using LED status indicator and software
I/O power supplyM8, 4-pin
Dynamic node allocation (DNA)Yes
ReACTION-capable I/O channelsYes
Fieldbus200 μs
EncoderM12, 12-pin, A-coded
Power output15 W X2X Link power supply for I/O modules
Internal I/O6 W
Type16 Mbit flash memory
Data retention20 years at 55°C
Guaranteed erase/write cycles100,000
CEYes
UKCAYes
CRA (Cyber Resilience Act)In preparation
ATEXZone 2, II 3G Ex nA IIA T5 Gc IP67, Ta = 0 – Max. 60°C TÜV 05 ATEX 7201X
ULcULus E115267 Industrial control equipment
HazLoccCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5
VariantPush/Pull
Line lengthMax. 100 m between 2 stations (segment length)
Transfer rate100 Mbit/s
Physical layer100BASE-TX
Half-duplexYes
Full-duplexNo
AutonegotiationYes
Auto-MDI/MDIXYes
Hub propagation delay0.96 to 1 µs
Synchronization between bus systems possibleYes
5 VDCModule-internal, max. 0.3 A summation current
24 VDCModule-internal, max. 0.5 A summation current
Voltage range18 to 30 VDC
Integrated protective functionReverse polarity protection
Sensor/Actuator power supplyMax. 12 W
VoltageI/O power supply minus voltage drop for short-circuit protection
Voltage drop for short-circuit protection at 0.5 AMax. 2 VDC
Summation currentMax. 0.5 A
Short-circuit proofYes
Quantity1
Encoder inputsDI 5 to DI 7, 5 V, symmetrical DI 1 to DI 4 and DI 8 to DI 9, 24 V, asymmetrical
Counter size32-bit
Input frequencyDI 1 to DI 7: 250 kHz DI 8 and DI 9: 100 kHz
Evaluation4x
Encoder power supply5 V: Module-internal, max. 0.3 A 24 V: Module-internal, max. 0.5 A
Overload characteristics of encoder power supplyShort-circuit proof, overload-proof
Input circuitSink
Insulation voltage between encoder and bus500 Veff
Hardware≤50 ns
SoftwareDefault 200 ns, configurable between 200 ns and 5 ms in 20 ns intervals
Input characteristics per EN 61131-2Type 1
Input voltage24 VDC -15/+20%
Channel 1 and 2Typ. 3 kΩ
Channel 3 and 4Typ. 8 kΩ
Channel 8 and 9Typ. 40 kΩ
Sensor power supply0.5 A summation current
Low<5 VDC
High<15 VDC
Input±10 V
Input typeSingle-ended
Digital converter resolution12-bit
Conversion time2 µs
Output formatExample: INT 0x8001 – 0x7FFF / 1 LSB = 0x0010 = 4.882 mV
Input protectionProtection against wiring with supply voltage
Open-circuit detectionYes, using software
Reverse polarity protectionYes
Permissible input signal±30 V
Undershoot0x8001
Overshoot0x7FFF
Conversion procedureSuccessive approximation
Gain0.15%
Offset0.05%
Crosstalk between channels-70 dB
Nonlinearity<0.15%
Output protectionShort-circuit proof
Output currentMax. 65 mA
Diagnostic statusOverload monitoring
Switching frequencyMax. 500 kHz
Nominal output current0.4 A
Braking voltage when switching off inductive loads50 VDC
Switch-on in the event of overload shutdown or short-circuit shutdownApprox. 25 ms
Peak short-circuit current<1 A
Switching voltage24 VDC (-15/+20%)
Resistive loadMax. 100 kHz
Inductive loadMax. 100 kHz
0 → 1<1 µs
1 → 0<1 µs
Output±10 V
Settling time on output change over entire range2.5 µs
Switch on/off behaviorInternal enable relay for startup
Load per channelMax. ±10 mA, load ≥1 kΩ
Output filterFirst-order low-pass filter / cutoff frequency 2.5 kHz
Max. gain drift0.012%/°C
Max. offset drift0.001%/°C
Error caused by load changeMax. 0.01%, from 10 MΩ → 1 kΩ, resistive
Output response when the power supply is switched on/offAn enable relay is switched on at a defined value ≠ 0, default setting = 10 kΩ to GND
Current limiting±40 mA
To actuator or I/O power supplyYes
To GNDYes
Electrical isolationBus isolated from POWERLINK and channel Channel not isolated from channel
AnyYes
0 to 2000 mNo limitation
>2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP67
Operation-25 to 60°C
Derating
Storage-40 to 85°C
Transport-40 to 85°C
Width53 mm
Height155 mm
Depth42 mm
Weight320 g
M8Max. 0.4 Nm
M12Max. 0.6 Nm