Fast delivery within 72 Hours

Wago 2604-1109

PCB terminal block, 2604 Series, 0 °conductor entry to boardThis PCB terminal block (item number 2604-1109) is designed for simple and secure connections. You can count on tried and tested safety with…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

PCB terminal block, 2604 Series, 0 °conductor entry to boardThis PCB terminal block (item number 2604-1109) is designed for simple and secure connections. You can count on tried and tested safety with these PCB terminal blocks, perfect for a host of applications when designing your devices. Rated current and voltage are important parameters when selecting a PCB terminal block, as they indicate how the product can be used. This product has a rated voltage of 400 V and a rated current of 32 A, making it suitable for high-load applications. Strip lengths must be between 9 mm and 11 mm when connecting conductors to this PCB terminal block. This product features one conductor terminal and utilizes Push-in CAGE CLAMP®. Push-in CAGE CLAMP® connection technology is ideal for connecting all conductor types. Solid and fine-stranded conductors with ferrules can be inserted without the need for tools—all thanks to its pluggable design. Dimensions: 47.4 x 20.7 x 19.2 mm (width x height x depth). This PCB terminal block is suitable for conductor cross sections ranging from 0.2 mm² to 4 mm². It features one level and nine clamping points that you can use to connect nine potentials / 9 poles. The clamping spring is made of chrome-nickel spring steel (CrNi), the gray housing is made of polyamide (PA66) for insulation, and the contacts are made of electrolytic copper (ECu). The contact surface is coated with tin. This PCB terminal block is operated with a lever. The PCB terminal block is designed for THT soldering. Insert the conductor into the board at an angle of 0°.. The solder pins measure 0.8 x 1 mm in cross-section and 4 mm in length and are laid out over the entire terminal strip (in-line). There are two solder pins per potential.

Specification

Notes

Variants:Other pole numbers, Direct marking, Other colors, Other versions (or variants) can be requested from WAGO Sales or configured at https://configurator.wago.com/.

Electrical data - Ratings per IEC/EN

Ratings perIEC/EN 60664-1
Nominal voltage (III/3)320 V
Rated impulse withstand voltage (III / 3)4 kV
Rated voltage (III/2)400 V
Rated impulse withstand voltage (III/2)4 kV
Nominal voltage (II/2)630 V
Rated impulse withstand voltage (II/2)4 kV
Rated current32 A
Legend (ratings)(III / 2) ≙ Overvoltage category III / Pollution degree 2
Ratings perIEC/EN 60664-1 / IEC/EN 60664-1 / IEC/EN 60664-1
Overvoltage categoryIII / III / II
Pollution degree3 / 2 / 2
Nominal voltage320 V / 400 V / 630 V
Rated impulse withstand voltage4 kV / 4 kV / 4 kV
Rated current32 A / 32 A / 32 A

Electrical data - Ratings per UL

Approvals perUL 1059
Rated voltage UL (Use Group B)300 V
Rated current UL (Use Group B)20 A
Rated voltage UL (Use Group D)300 V
Rated current UL (Use Group D)10 A
Approvals perUL 1059 / UL 1059 / UL 1059
Use groupB / C / D
Rated voltage300 V / 300 V
Rated current20 A / 10 A

Electrical data - Ratings per CSA

Approvals perCSA
Rated voltage CSA (Use Group B)300 V
Rated current CSA (Use Group B)20 A
Rated voltage CSA (Use Group D)300 V
Rated current CSA (Use Group D)5 A
Approvals perCSA / CSA / CSA
Use groupB / C / D
Rated voltage300 V / 300 V
Rated current20 A / 5 A

Connection data

Clamping units9
Total number of potentials9
Number of connection types1
Number of levels1

Connection data - Connection 1

Connection technologyPush-in CAGE CLAMP®
Actuation typeLever
Solid conductor0.2 … 4 mm² / 24 … 12 AWG
Fine-stranded conductor0.2 … 4 mm² / 24 … 12 AWG
Fine-stranded conductor; with insulated ferrule0.25 … 2.5 mm²
Fine-stranded conductor; with uninsulated ferrule0.25 … 2.5 mm²
Fine-stranded conductor; with twin ferrule0.25 … 1.5 mm²
Strip length9 … 11 mm / 0.35 … 0.43 inches
Conductor connection direction to PCB0 °
Pole number9

Physical data

Pin spacing5 mm / 0.197 inches
Width47.4 mm / 1.866 inches
Height20.7 mm / 0.815 inches
Height from the surface16.7 mm / 0.657 inches
Depth19.2 mm / 0.756 inches
Solder pin length4 mm
Solder pin dimensions0.8 x 1 mm
Drilled hole diameter with tolerance1.3 (+0.1) mm

PCB contact

PCB contactTHT
Solder pin arrangementover the entire terminal strip (in-line)
Number of solder pins per potential2

Material data

Note (material data)Information on material specifications can be found here
Colorgray
Material groupI
Insulation material (main housing)Polyamide (PA66)
Flammability class per UL94V0
Clamping spring materialChrome-nickel spring steel (CrNi)
Contact materialElectrolytic copper (ECu)
Contact platingTin
Fire load0.361 MJ
Actuator colororange
Weight13.5 g

Environmental requirements

Limit temperature range-60 … +105 °C
Processing temperature-35 … +60 °C
Continuous operating temperature-60 … +105 °C

Environmental requirements - Environmental Testing

Test specification: <br/>Railway applications –<br/>Rolling stock –<br/>Electronic equipmentDIN EN 50155 (VDE 0115-200):2022-06
Test procedure: <br/>Railway applications – <br/>Rolling stock equipment – <br/>Vibration and shock testsDIN EN 61373 (VDE 0115-0106):2011-04
Spectrum/Mounting locationService life test, Category 1, Class A/B
Functional test with noise-like oscillationsTest passed according to Section 8 of the standard
Frequencyf1 = 5 Hz to f2 = 150 Hz
Acceleration0.101g (highest test level used for all axes)
Test duration per axis10 min.
Test directionsX, Y and Z axes
Monitoring of contact faults and interruptionsPassed
Voltage drop measurement before and after each axisPassed
Simulated service life test through increased levels of noise-like oscillationsTest passed according to Section 9 of the standard
Frequencyf1 = 5 Hz to f2 = 150 Hz
Acceleration0.572g (highest test level used for all axes)
Test duration per axis5 h
Test directionsX, Y and Z axes
Extended testing: Monitoring of contact faults and interruptionsPassed
Extended testing: Voltage drop measurement before and after each axisPassed
Shock testTest passed according to Section 10 of the standard
Shock pulse formHalf sine
Acceleration5g (highest test level used for all axes)
Shock duration30 ms
Number of shocks (per axis)3 pos. und 3 neg.
Test directionsX, Y and Z axes
Extended testing: Monitoring of contact faults and interruptionsPassed
Extended testing: Voltage drop measurement before and after each axisPassed
Vibration and shock stress for rolling stock equipmentPassed

Commercial data

PU (SPU)40 pcs
Packaging typebox
Country of originDE
GTIN4055143564366
Customs tariff number85369010000

Product Classification

UNSPSC39121409
eCl@ss 10.027-44-04-01
eCl@ss 9.027-44-04-01
ETIM 9.0EC002643
ETIM 10.0EC002643
ECCNNO US CLASSIFICATION

Environmental Product Compliance

RoHS Compliance StatusCompliant,No Exemption

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Wago 2604-1109”

Your email address will not be published. Required fields are marked *