B&R X20RT8381

reACTION Technology module4 high-speed digital inputs4 high-speed digital channels, configurable as inputs or outputs2 high-speed analog inputs ±10 V1 high-speed analog output ±10 V1 ABR incremental e…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

reACTION Technology module4 high-speed digital inputs4 high-speed digital channels, configurable as inputs or outputs2 high-speed analog inputs ±10 V1 high-speed analog output ±10 V1 ABR incremental encoder input 24 VPulse width modulationSupport of data type “REAL” for arithmetic operationsSupports blackout mode

This reACTION Technology module is equipped with 4 high-speed digital inputs and 4 high-speed digital mixed channels. All connections are designed for 1-wire connections. All inputs are designed for sink connections; the outputs are designed for push-pull connections.A voltage signal of ±10 V can be read or output using 2 analog inputs and 1 analog output, respectively.Ultrafast reACTION Technology makes it possible to control the integrated I/O channels with response times down to 1 μs. All of the commands that can be used for reACTION programs are provided as function blocks in special libraries (e.g. AsIORTI). Programming in compliance with IEC 61131-3 requirements takes place in the Function Block Diagram editor in Automation Studio.The module supports blackout mode. In blackout mode, programmable module functionality persists even if the network fails.

Specification

I/O module4 digital input channels, 4 digital channels configurable as inputs or outputs, 2 analog inputs ±10 V, 1 analog output ±10 V, reACTION Technology
B&R ID code0xF24E
Status indicatorsI/O function per channel, operating state, module status
Module run/errorYes, using LED status indicator and software
OutputsYes, using LED status indicator and software (output error status)
InputsYes, using LED status indicator and software
Channel typeYes, using software
ReACTION-capable I/O channelsYes
ScopeModule
FunctionProgrammable
Standalone modeNo
Bus0.01 W
Internal I/O1.7 W
Additional power dissipation caused by actuators (resistive) [W]+1.1
Type of signal linesShielded lines must be used for all signal lines, line length: Max. 20 m
Type64 Mbit flash memory
Data retention20 years at 55°C
Guaranteed erase/write cycles100,000
CEYes
UKCAYes
CRA (Cyber Resilience Act)In preparation
ULcULus E115267 Industrial control equipment
DNVTemperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck)
CCSYes
LRENV1
KRYes
ABSYes
BVEC33B Temperature: 5 – 55°C Vibration: 4 g EMC: Bridge and open deck
Quantity1
Nominal voltage24 VDC
Input voltage24 VDC -15% / +20%
Input current at 24 VDCTyp. 1.3 mA
Input circuitSink
Hardware<3 µs
SoftwareDefault 200 ns, configurable between 200 ns and 5 ms in 10 ns intervals
Connection type1-wire connections
Input resistance18.16 kΩ
Low<5 VDC
High>15 VDC
Insulation voltage between channel and bus500 Veff
Encoder inputs24 V, asymmetrical
Counter size32-bit
Input frequencyMax. 333 kHz
Evaluation4x
Input±10 V
Input typeDifferential input
Digital converter resolution±12-bit
Data typeINT
VoltageINT 0x8000 – 0x7FFF / 1 LSB = 0x0008 = 2.441 mV
Input impedance in signal range20 MΩ
Input protectionProtection against wiring with supply voltage
Permissible input signalMax. ±30 V
Undershoot0x8001
Overshoot0x7FFF
Conversion procedureSAR
Input filterThird-order low-pass filter / Cutoff frequency 130 kHz
Gain0.15%
Offset0.05%
Max. gain drift0.022 %/°C
Max. offset drift0.032%/°C
DC86 dB
50 Hz84 dB
Common-mode range±12 V
Nonlinearity0.005%
Sampling frequency500 kHz
VariantPush-Pull
Switching voltage24 VDC -15% / +20%
Nominal output current100 mA
Total nominal current400 mA
Output circuitSink or source
Output protectionShort-circuit proof
Diagnostic statusOutput monitoring with delay <700 ns
Leakage current when the output is switched offApprox. 25 µA
RDS(on)140 mΩ
Residual voltage<0.4 V at nominal current 100 mA
Max. continuous current100 mA
Peak short-circuit current<10 A
Switch-on in the event of overload shutdown or short-circuit shutdownApprox. 3 ms
0 → 1<1 µs
1 → 0<1 µs
Resistive loadMax. 500 kHz
Output±10 V
Conversion time2 μs
Settling time on output change over entire range5 μs
Switch on/off behaviorInternal enable relay for startup
Load per channelMax. ±10 mA, load ≥1 kΩ
Short-circuit proofCurrent limiting ±65 mA
Output filterFirst-order low-pass filter / cutoff frequency 22 kHz
Error caused by load changeMax. 0.14%, from 10 MΩ → 1 kΩ, resistive
Electrical isolationChannel isolated from bus Channel not isolated from channel
HorizontalYes
VerticalYes
0 to 2000 mNo limitation
>2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP20
Horizontal mounting orientation-25 to 60°C
Vertical mounting orientation-25 to 50°C
DeratingSee section “Derating and hardware configuration”.
Storage5 to 95%, non-condensing
Transport5 to 95%, non-condensing
Operation5 to 95%, non-condensing
NoteOrder 2x terminal block X20TB12 separately. Order 1x bus module X20BM31 separately.
Pitch25+0.2 mm