Fast delivery within 72 Hours

B&R X20RT8001

reACTION technology module4 high-speed digital inputs4 high-speed digital channels, configurable as inputs or outputs1 ABR incremental encoder input 24 VPulse width modulation24 VDC and GND for encode…

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

2-3 Days

From $20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From $40

  • Warranty 1 year
  • Free 30-Day returns

Description

reACTION technology module4 high-speed digital inputs4 high-speed digital channels, configurable as inputs or outputs1 ABR incremental encoder input 24 VPulse width modulation24 VDC and GND for encoder supplySupports blackout mode

This reACTION technology module has four high-speed digital inputs and four high-speed digital mixed channels. All connections are designed for 1-wire connections. All inputs are designed for sink connections, the outputs for push-pull connections.Ultrafast reACTION Technology makes it possible to control the integrated I/O channels with response times down to 1 μs. All of the commands that can be used for reACTION programs are provided as function blocks in special libraries (e.g. AsIORTI). Programming in compliance with IEC 61131-3 requirements takes place in the Function Block Diagram editor in Automation Studio.The module supports blackout mode. In blackout mode, programmable module functionality persists even if the network fails.

Specification

I/O module

4 digital input channels, 4 digital channels configurable as inputs or outputs, reACTION Technology

B&R ID code

0xE559

Status indicators

I/O function per channel, operating state, module status

Module run/error

Yes, using LED status indicator and software

Outputs

Yes, using LED status indicator and software (output error status)

ReACTION-capable I/O channels

Yes

Scope

Module

Function

Programmable

Standalone mode

No

Bus

0.01 W

Internal I/O

1 W

Additional power dissipation caused by actuators (resistive) [W]

+0.6

Type of signal lines

Shielded cables must be used for all signal lines, cable length: Max. 20 m

Type

64 Mbit flash memory

Data retention

20 years at 55°C

Guaranteed erase/write cycles

100,000

CE

Yes

UKCA

Yes

CRA (Cyber Resilience Act)

In preparation

ATEX

Zone 2, II 3G Ex nA nC IIA T5 Gc
IP20, Ta (see X20 user's manual)
FTZÚ 09 ATEX 0083X

UL

cULus E115267
Industrial control equipment

HazLoc

cCSAus 244665
Process control equipment
for hazardous locations
Class I, Division 2, Groups ABCD, T5

DNV

Temperature: B (0 to 55°C)
Humidity: B (up to 100%)
Vibration: B (4 g)
EMC: B (bridge and open deck)

CCS

Yes

LR

ENV1

KR

Yes

ABS

Yes

BV

EC33B
Temperature: 5 – 55°C
Vibration: 4 g
EMC: Bridge and open deck

Output voltage

24 VDC -15% / +20%

Output current

Module-internal, max. 600 mA

Short-circuit proof, overload protection

Yes

Quantity

4 mixed channels, configuration as input or output using software

Nominal voltage

24 VDC

Input voltage

24 VDC -15% / +20%

Input current at 24 VDC

Typ. 1.3 mA

Input circuit

Sink

Hardware

<3 µs

Software

Default 200 ns, configurable between 200 ns and 5 ms in 10 ns intervals

Connection type

1-wire connections

Input resistance

18.16 kΩ

Low

<5 VDC

High

>15 VDC

Insulation voltage between channel and bus

500 Veff (Rev. <E0); 856 VAC (Rev. ≥E0)

Encoder inputs

24 V, asymmetrical

Counter size

32-bit

Input frequency

Max. 333 kHz

Evaluation

4x

Variant

Push-Pull

Switching voltage

24 VDC -15% / +20%

Nominal output current

100 mA (Rev. <E0)
Configurable: 100/530 mA (Rev. ≥E0)

Total nominal current

400 mA (Rev. <E0); 2.12 A (Rev. ≥E0)

Output circuit

Sink or source

Output protection

Thermal shutdown in the event of overcurrent or short circuit (see value "Short-circuit peak current")

Diagnostic status

Output monitoring with delay <700 ns

Leakage current when the output is switched off

Approx. 25 µA

RDS(on)

140 mΩ

Residual voltage

<0.4 V at nominal current

Max. continuous current

100 mA (Rev. <E0); 530 mA (Rev. ≥E0)

Peak short-circuit current

<10 A

Switch-on in the event of overload shutdown or short-circuit shutdown

Approx. 3 ms

0 → 1

<1 µs

1 → 0

<1 µs

Resistive load

100 mA: Max. 500 kHz
530 mA: Max. 20 Hz (Rev. ≥E0)

Electrical isolation

Channel isolated from bus
Channel not isolated from channel

Horizontal

Yes

Vertical

Yes

0 to 2000 m

No limitation

>2000 m

Reduction of ambient temperature by 0.5°C per 100 m

Degree of protection per EN 60529

IP20

Horizontal mounting orientation

-25 to 60°C

Vertical mounting orientation

-25 to 50°C

Derating

See section "Derating and hardware configuration".

Storage

5 to 95%, non-condensing

Transport

5 to 95%, non-condensing

Operation

5 to 95%, non-condensing

Note

Order 1x terminal block X20TB12 separately.
Order 1x bus module X20BM11 separately.

Pitch

12.5+0.2 mm

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “B&R X20RT8001”

Your email address will not be published. Required fields are marked *