Fast delivery within 72 Hours

B&R X20PS9500

 274,54

4 in stock

Supply for Compact or Fieldbus CPU, X2X Link network and internal I/O power supplyElectrical isolation of supply and CPU / X2X Link power supplyRedundancy of CPU / X2X Link supply possible by operatin…

4 in stock

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Supply for Compact or Fieldbus CPU, X2X Link network and internal I/O power supplyElectrical isolation of supply and CPU / X2X Link power supplyRedundancy of CPU / X2X Link supply possible by operating multiple supply modules simultaneouslyRS232 configurable as an online interfaceCAN bus

The power supply module is used together with an X20 Compact or Fieldbus CPU. It is equipped with a supply for the Compact or Fieldbus CPU, X2X Link network and internal I/O power supply.

Specification

Power supply module24 VDC power supply module for Compact or Fieldbus CPU, X2X Link power supply and I/O
Interfaces1x RS232, 1x CAN bus
B&R ID code0x2018
Status indicatorsOverload, operating state, module status, RS232, CAN bus
Module run/errorYes, using LED status indicator and software
CAN bus data transferYes, using LED status indicator
RS232 data transferYes, using LED status indicator
OverloadYes, using LED status indicator and software
Internal I/O0.6 W
Additional power dissipation caused by actuators (resistive) [W]
CEYes
UKCAYes
ATEXZone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user’s manual) FTZÚ 09 ATEX 0083X
ULcULus E115267 Industrial control equipment
HazLoccCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5
DNVTemperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck)
CCSYes
LRENV1
KRYes
ABSYes
BVEC33B Temperature: 5 – 55°C Vibration: 4 g EMC: Bridge and open deck
KCYes
Input voltage24 VDC -15% / +20%
Input currentMax. 0.7 A
FuseRequired line fuse: Max. 10 A, slow-blow
Reverse polarity protectionNo
Nominal output power7 W
Parallel connectionYes
Redundant operationYes
Overload characteristicsShort-circuit proof, temporary overload
Nominal output voltage24 VDC
Behavior on short circuitRequired line fuse
Permissible contact load10 A
SignalCAN bus
VariantConnection via 12-pin terminal block X20TB12
Transfer rateMax. 1 Mbit/s
Electrical isolationCPU/X2X Link supply isolated from CPU/X2X Link power supply I/O supply not isolated from I/O power supply
HorizontalYes
VerticalYes
0 to 2000 mNo limitation
>2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP20
Horizontal mounting orientation-25 to 60°C
Vertical mounting orientation-25 to 50°C
DeratingSee section “Derating”.
Storage5 to 95%, non-condensing
Transport5 to 95%, non-condensing
Operation5 to 95%, non-condensing
NoteOrder 1x terminal block X20TB12 separately. Order 1x Compact CPU base X20BB22 or X20BB27 separately Order 1x Fieldbus CPU base X20BB3x/4x separately
Pitch12.5+0.2 mm

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “B&R X20PS9500”

Your email address will not be published. Required fields are marked *