Fast delivery within 72 Hours
B&R X20PS9400
€ 26,50 – € 47,70Price range: € 26,50 through € 47,70
Supply for the bus controller, X2X Link and internal I/O supplyFeed and bus controller / X2X Link supply electrically isolatedRedundancy of bus controller / X2X Link supply possible by operating multi…
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Supply for the bus controller, X2X Link and internal I/O supplyFeed and bus controller / X2X Link supply electrically isolatedRedundancy of bus controller / X2X Link supply possible by operating multiple supply modules simultaneouslyService interface (RS232)
The supply module is used together with an X20 bus controller. It is equipped with a feed for the bus controller, the X2X Link and the internal I/O supply.
Specification
| Power supply module | 24 VDC supply module for bus controller, X2X Link power supply and I/O |
|---|---|
| Interfaces | 1x RS232 service interface |
| B&R ID code | 0x1F8C |
| Status indicators | Overload, operating status, module status, RS232 |
| Module run/error | Yes, using LED status indicator and software |
| RS232 data transfer | Yes, using LED status indicator |
| Overload | Yes, using LED status indicator and software |
| Power consumption for X2X Link power supply | 1.42 W |
| Internal I/O | 0.6 W |
| Additional power dissipation caused by actuators (resistive) [W] | – |
| CE | Yes |
| UKCA | Yes |
| CRA (Cyber Resilience Act) | In preparation |
| ATEX | Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user’s manual) FTZÚ 09 ATEX 0083X |
| UL | cULus E115267 Industrial control equipment |
| HazLoc | cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5 |
| DNV | Temperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck) |
| CCS | Yes |
| LR | ENV1 |
| KR | Yes |
| ABS | Yes |
| BV | EC33B Temperature: 5 – 55°C Vibration: 4 g EMC: Bridge and open deck |
| KC | Yes |
| Input voltage | 24 VDC -15% / +20% |
| Input current | Max. 0.7 A |
| Fuse | Required line fuse: Max. 10 A, slow-blow |
| Reverse polarity protection | No |
| Nominal output power | 7 W |
| Parallel connection | Yes |
| Redundant operation | Yes |
| Overload characteristics | Short-circuit proof, temporary overload |
| Nominal output voltage | 24 VDC |
| Behavior on short circuit | Required line fuse |
| Permissible contact load | 10 A |
| Signal | RS232 |
| Variant | Connection made using 12-pin terminal block X20TB12 |
| Max. transfer rate | 115.2 kbit/s |
| Electrical isolation | BC/X2X Link supply isolated from BC/X2X Link power supply I/O supply not isolated from I/O power supply, and RS232 not isolated from bus |
| Horizontal | Yes |
| Vertical | Yes |
| 0 to 2000 m | No limitation |
| >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 | IP20 |
| Horizontal mounting orientation | -25 to 60°C |
| Vertical mounting orientation | -25 to 50°C |
| Derating | See section “Derating”. |
| Storage | 5 to 95%, non-condensing |
| Transport | 5 to 95%, non-condensing |
| Operation | 5 to 95%, non-condensing |
| Note | Order 1x terminal block X20TB12 separately. Order 1x bus base X20BB8x separately. |
| Pitch | 12.5+0.2 mm |
| Condition | New, New Without Box, Refurbished, Used |
| Revision | Rev. D0, Rev. F0, Rev. G0, Rev. I0 |

Reviews
Clear filtersThere are no reviews yet.