Integrated exchangeable microfuseMonitoring of the fusePotential for routing as neededCan be used as feed module for the I/O supply
The potential distribut…
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Integrated exchangeable microfuseMonitoring of the fusePotential for routing as neededCan be used as feed module for the I/O supply
The potential distributor module with feed can provide 6x 24 VDC and 6x ground connections from the internal I/O supply on the terminals. This module can also be used instead of a special feed module for the internal I/O supply. The internal 24 VDC supply is connected to the terminal connections through a replaceable microfuse for protection. The 24 VDC feed and the functionality of the fuse are monitored.
Specification
| Potential distributor module with supply | 6x 24 VDC on the terminals, 6x ground on the terminals |
|---|---|
| B&R ID code | 0x267F |
| Status indicators | Operating state, module status |
| Module run/error | Yes, using LED status indicator and software |
| Fuse monitoring | Yes, using LED status indicator and software |
| Bus | 0.12 W |
| Internal I/O | 1.15 W |
| External I/O | 1.15 W |
| Additional power dissipation caused by actuators (resistive) [W] | – |
| CE | Yes |
| UKCA | Yes |
| CRA (Cyber Resilience Act) | In preparation |
| ATEX | Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user’s manual) FTZÚ 09 ATEX 0083X |
| UL | cULus E115267 Industrial control equipment |
| HazLoc | cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5 |
| DNV | Temperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck) |
| CCS | Yes |
| LR | ENV1 |
| KR | Yes |
| ABS | Yes |
| BV | EC33B Temperature: 5 – 55°C Vibration: 4 g EMC: Bridge and open deck |
| KC | Yes |
| Nominal input voltage | 24 VDC -15% / +20% external, ground external |
| Input current | Max. 6 A |
| Fuse | Integrated 6.3 A, slow-blow, can be replaced |
| Behavior on short circuit | No protection available Use an external fuse. |
| Reverse polarity protection | No |
| Nominal output voltage | 24 VDC, ground |
| Permissible contact load | 6 A |
| On 24 VDC power supply | Integrated fuse |
| On GND power supply | No protection available |
| Horizontal | Yes |
| Vertical | Yes |
| 0 to 2000 m | No limitation |
| >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 | IP20 |
| Horizontal mounting orientation | -25 to 60°C |
| Vertical mounting orientation | -25 to 50°C |
| Derating | – |
| Storage | 5 to 95%, non-condensing |
| Transport | 5 to 95%, non-condensing |
| Operation | 5 to 95%, non-condensing |
| Note | Order 1x terminal block X20TB12 separately. Order 1x bus module X20BM01 or X20BM11 separately. |
| Pitch | 12.5+0.2 mm |