Fast delivery within 72 Hours
B&R X20DO2633
€ 369,94
3 in stock
2 digital outputsOutputs with integrated snubber circuitOutputs with 48 to 240 VACL switchingZero-crossing detectionPhase-angle controlOpen-circuit detection for each channelNegative half-waves can be…
3 in stock
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
2 digital outputsOutputs with integrated snubber circuitOutputs with 48 to 240 VACL switchingZero-crossing detectionPhase-angle controlOpen-circuit detection for each channelNegative half-waves can be switched off50 Hz or 60 Hz3-wire connections240 V codingOSP modeFrequency mode
The module is a digital output module with phase-angle control that is equipped with 2 Triac outputs using 3-line connections. The supply (L and N) is fed directly to the module.
Specification
| I/O module | 2 digital outputs 48 to 240 VAC for 3-wire connections |
|---|---|
| B&R ID code | 0xAC39 |
| Status indicators | I/O function per channel, operating state, module status |
| Module run/error | Yes, using LED status indicator and software |
| Outputs | Yes, using LED status indicator and software |
| Bus | 0.6 W |
| Internal I/O | – |
| External I/O | – |
| Additional power dissipation caused by actuators (resistive) [W] | +6 |
| CE | Yes |
| UKCA | Yes |
| CRA (Cyber Resilience Act) | In preparation |
| ATEX | Zone 2, II 3G Ex nA nC IIA T5 GcIP20, Ta (see X20 user’s manual)FTZÚ 09 ATEX 0083X |
| UL | cULus E115267Industrial control equipment |
| HazLoc | cCSAus 244665Process control equipmentfor hazardous locations Class I, Division 2, Groups ABCD, T5 |
| KC | Yes |
| Variant | Triac |
| Circuit | L-switching |
| Nominal voltage | 48 to 240 VAC |
| Max. voltage | 264 VAC |
| Rated frequency | 47 to 63 Hz |
| Nominal output current | 2 A |
| Total nominal current | 4 A |
| Output current | 2.5 A |
| Summation current | 5 A |
| Connection type | 3-wire connections |
| Zero-crossing detection | Yes |
| Minimum holding current IH | 15 mA |
| Leakage current | Max. 2 mA at 240 V at 50 HzMax. 2.4 mA at 240 V at 60 Hz |
| Residual voltage (on-state voltage) | 1.5 V |
| Area | 5 to 95% |
| Resolution | 1% |
| Accuracy (60 to 240 VAC) | <100 μs |
| Voltage monitoring L - N | Yes |
| Additional functions | Open-circuit detection |
| Overvoltage protection between L and N | Yes, varistor |
| Channel - Bus | Tested with 2300 VAC (Rev. <E0 1500 VAC) |
| Channel - Internal I/O | Tested with 2300 VAC (Rev. <E0 2000 VAC) |
| Channel - Ground | Tested with 2300 VAC (Rev. <E0 1500 VAC) |
| External | See section “External fuses”. |
| Internal | Snubber circuit (RC element) and varistor |
| Electrical isolation | Channel isolated from bus and I/O power supply |
| Horizontal | Yes |
| Vertical | Yes |
| 0 to 2000 m | No limitation |
| >2000 m | Not permitted |
| Degree of protection per EN 60529 | IP20 |
| Horizontal mounting orientation | -25 to 60°C |
| Vertical mounting orientation | -25 to 50°C |
| Derating | See section “Derating”. |
| Storage | 5 to 95%, non-condensing |
| Transport | 5 to 95%, non-condensing |
| Operation | 5 to 95%, non-condensing |
| Note | Order 1x terminal block X20TB32 separately.Order 1x bus module X20BM32 separately. |
| Pitch | 25+0.2 mm |

Reviews