Fast delivery within 72 Hours

B&R X20DO2322

 30,74

12 in stock

2 digital outputsSource connection3-wire connections24 VDC and GND for actuator supplyIntegrated output protectionOSP mode

This module is equipped with 2 o…

12 in stock

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

2 digital outputsSource connection3-wire connections24 VDC and GND for actuator supplyIntegrated output protectionOSP mode

This module is equipped with 2 outputs with 3-wire connections as well as 24 VDC and GND for the actuator power supply. The outputs are designed for a source circuit. This module is designed for the 6-pin X20 terminal block. For logistical reasons, for example, the 12-pin terminal block can also be used.

Specification

I/O module2 digital outputs 24 VDC for 3-wire connections
B&R ID code0x1B96
Status indicatorsI/O function per channel, operating state, module status
Module run/errorYes, using LED status indicator and software
OutputsYes, using LED status indicator and software (output error status)
Bus0.13 W
Internal I/O0.33 W
Additional power dissipation caused by actuators (resistive) [W]+0.1
CEYes
UKCAYes
CRA (Cyber Resilience Act)In preparation
ATEXZone 2, II 3G Ex nA nC IIA T5 GcIP20, Ta (see X20 user’s manual)FTZÚ 09 ATEX 0083X
ULcULus E115267Industrial control equipment
HazLoccCSAus 244665Process control equipmentfor hazardous locations Class I, Division 2, Groups ABCD, T5
DNVTemperature: B (0 to 55°C)Humidity: B (up to 100%)Vibration: B (4 g)EMC: B (bridge and open deck)
CCSYes
LRENV1
KRYes
ABSYes
BVEC33BTemperature: 5 – 55°CVibration: 4 gEMC: Bridge and open deck
KCYes
VariantCurrent-sourcing FET
Nominal voltage24 VDC
Switching voltage24 VDC -15% / +20%
Nominal output current0.5 A
Total nominal current1 A
Connection type3-wire connections
Output circuitSource
Output protectionThermal shutdown in the event of overcurrent or short circuit (see value “Short-circuit peak current”)Internal freewheeling diode for switching inductive loads (see section “Switching inductive loads”)
Actuator power supplyMax. 12 W
Diagnostic statusOutput monitoring with 10 ms delay
Leakage current when the output is switched off5 µA
RDS(on)210 mΩ
Peak short-circuit current<12 A
Switch-on in the event of overload shutdown or short-circuit shutdownApprox. 10 ms (depends on the module temperature)
0 → 1<300 µs
1 → 0<300 µs
Resistive loadMax. 500 Hz
Inductive loadSee section “Switching inductive loads”.
Braking voltage when switching off inductive loadsTyp. 50 VDC
Insulation voltage between channel and bus500 Veff
VoltageModule power supply minus voltage drop for short-circuit protection
Voltage drop for short-circuit protection at 500 mAMax. 2 V
Short-circuit proofYes
Electrical isolationChannel isolated from busChannel not isolated from channel and I/O power supply
HorizontalYes
VerticalYes
0 to 2000 mNo limitation
>2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP20
Horizontal mounting orientation-25 to 60°C
Vertical mounting orientation-25 to 50°C
Derating
Storage5 to 95%, non-condensing
Transport5 to 95%, non-condensing
Operation5 to 95%, non-condensing
NoteOrder 1x terminal block X20TB06 or X20TB12 separately. Order 1x bus module X20BM11 separately.
Pitch12.5+0.2 mm

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “B&R X20DO2322”

Your email address will not be published. Required fields are marked *