Fast delivery within 72 Hours
B&R X20DI2377
2 digital inputsSink connection3-wire connections2 counter inputs with 50 kHz counter frequencyGate measurement24 VDC and GND for sensor supplySoftware input filter can be configured for entire module…
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
From $20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From $40
-
Warranty 1 year
-
Free 30-Day returns
Description
2 digital inputsSink connection3-wire connections2 counter inputs with 50 kHz counter frequencyGate measurement24 VDC and GND for sensor supplySoftware input filter can be configured for entire module
The module is equipped with two inputs for 3-wire connections. Both inputs can be configured as event counters. Gate measurement is only ever possible on one channel. This module is designed for X20 6-pin terminal blocks. If needed (e.g. for logistical reasons), the 12-pin terminal block can also be used.
Specification
| I/O module |
2 digital inputs 24 VDC for 3-wire connections, special functions |
|---|---|
| B&R ID code |
0x1B8E |
| Status indicators |
I/O function per channel, operating state, module status |
| Module run/error |
Yes, using LED status indicator and software |
| Bus |
0.15 W |
| Internal I/O |
0.82 W |
| Additional power dissipation caused by actuators (resistive) [W] |
– |
| CE |
Yes |
| UKCA |
Yes |
| CRA (Cyber Resilience Act) |
In preparation |
| ATEX |
Zone 2, II 3G Ex nA nC IIA T5 Gc |
| UL |
cULus E115267 |
| HazLoc |
cCSAus 244665 |
| DNV |
Temperature: B (0 to 55°C) |
| CCS |
Yes |
| LR |
ENV1 |
| KR |
Yes |
| ABS |
Yes |
| BV |
EC33B |
| KC |
Yes |
| Nominal voltage |
24 VDC |
| Input characteristics per EN 61131-2 |
Type 1 |
| Input voltage |
24 VDC -15% / +20% |
| Input current at 24 VDC |
Typ. 10.5 mA |
| Input circuit |
Sink |
| Hardware |
≤10 μs |
| Software |
Default 0 ms, configurable between 0 and 25 ms in 0.2 ms intervals |
| Connection type |
3-wire connections |
| Input resistance |
Typ. 2.23 kΩ |
| Additional functions |
50 kHz event counting, gate measurement |
| Low |
<5 VDC |
| High |
>15 VDC |
| Insulation voltage between channel and bus |
500 Veff |
| Quantity |
2 |
| Signal form |
Square wave pulse |
| Evaluation |
Positive edge – Negative edge |
| Input frequency |
Max. 50 kHz |
| Counter 1 |
Input 1 |
| Counter 2 |
Input 2 |
| Counter frequency |
Max. 50 kHz |
| Counter size |
16-bit |
| Number of gate time measurements |
1 |
| Internal |
48 MHz, 24 MHz, 12 MHz, 6 MHz, 3 MHz, 1.5 MHz, 750 kHz, 375 kHz, 187.5 kHz |
| Length of pause between pulses |
≥100 µs |
| Pulse length |
≥20 µs |
| Supported inputs |
Input 1 or input 2 |
| Power consumption |
Max. 12 W |
| Voltage |
Module power supply minus voltage drop for short-circuit protection |
| Voltage drop for short-circuit protection at 500 mA |
Max. 2 VDC |
| Summation current |
0.5 A |
| Short-circuit proof |
Yes |
| Electrical isolation |
Channel isolated from bus |
| Horizontal |
Yes |
| Vertical |
Yes |
| 0 to 2000 m |
No limitation |
| >2000 m |
Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 |
IP20 |
| Horizontal mounting orientation |
-25 to 60°C |
| Vertical mounting orientation |
-25 to 50°C |
| Derating |
– |
| Storage |
5 to 95%, non-condensing |
| Transport |
5 to 95%, non-condensing |
| Operation |
5 to 95%, non-condensing |
| Note |
Order 1x terminal block X20TB06 or X20TB12 separately. |
| Pitch |
12.5+0.2 mm |

Reviews