B&R X20DC2190

Ultrasonic transducer modulePath measurement (resolution 10 µm)Speed measurement (resolution 100 µm/s)1, 2, 3 and 4 magnetic rod measurements possibleDPI/IP protocol supported…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Ultrasonic transducer modulePath measurement (resolution 10 µm)Speed measurement (resolution 100 µm/s)1, 2, 3 and 4 magnetic rod measurements possibleDPI/IP protocol supported

This module can be used to determine paths and to calculate speeds at the same time. The ultrasonic transducer rods are connected directly to the RS422 interface. Communication to the transducer rod takes place using start/stop signals. With the DPI/IP protocol, it is also possible, for example, to read operational properties directly from the transducer. During service (when a transducer is being exchanged) the machine can be started again quickly without additional configuration work. The module is designed for connecting 2 transducer rods with a total of up to 4 paths. That means, for example, that 2 ultrasonic transducers with 2 magnets each or one with 4 magnets can be used. The combination 3/1 is also possible. The module provides 24 VDC as an external supply for the sensor.

Specification

I/O moduleUltrasonic path measurement module, 2 path measurement rods, 4 path recorders, speed measurement
B&R ID code0x2188
Status indicatorsI/O function per channel, operating state, module status
Module run/errorYes, using LED status indicator and software
Bus0.01 W
Internal I/O1.1 W
Additional power dissipation caused by actuators (resistive) [W]
CEYes
UKCAYes
CRA (Cyber Resilience Act)In preparation
ATEXZone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user’s manual) FTZÚ 09 ATEX 0083X
ULcULus E115267 Industrial control equipment
HazLoccCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5
KCYes
Quantity2
Supported encoder typesStart/Stop interface EP start/stop interface DPI/IP interface
Voltage24 VDC, module-internal, max. 150 mA
MonitoringConfigurable overvoltage/undervoltage monitoring (±10%, ±15%, ±20%, ±25%)
Short-circuit proofRev. D0 and later
Input and output levelRS422 differential level
Multi-magnet measurementYes, in combination per rod, max. 4 magnets total
Outputs1.6 µs durational initialization pulse
Path measurementResolution = 0.01 mm, measurement range = ±5.2 m
Speed measurementResolution = 0.1 mm/s, measurement range = ±3.2 m/s
Accuracy±50 ppm ±5 ppm/year
Short-circuit protectionNo
Electrical isolationChannel isolated from bus Channel not isolated from channel
HorizontalYes
VerticalYes
0 to 2000 mNo limitation
>2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP20
Horizontal mounting orientation-25 to 60°C
Vertical mounting orientation-25 to 50°C
Derating
Storage5 to 95%, non-condensing
Transport5 to 95%, non-condensing
Operation5 to 95%, non-condensing
NoteOrder 1x terminal block X20TB12 separately. Order 1x bus module X20BM11 separately.
Pitch12.5+0.2 mm