Fast delivery within 72 Hours

Wago 252-308

Pluggable pcb terminal block, 252 Series, grayOur pluggable pcb terminal block (item number 252-308) simplifies electrical installations. Conductors should only be connected to pluggable pcb terminal…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Pluggable pcb terminal block, 252 Series, grayOur pluggable pcb terminal block (item number 252-308) simplifies electrical installations. Conductors should only be connected to pluggable pcb terminal block if their strip length is between 6 mm and 7 mm. This product features one conductor terminal and utilizes PUSH WIRE®. Our PUSH WIRE® connection is the simple and reliable method for connecting solid conductors. The dimensions are 28 x 11 x 10.5 mm (width x height x depth). Pluggable pcb terminal block is suitable for conductor cross sections ranging from 0.14 mm² to 0.5 mm². It has one level. Eight potentials can connect eight poles using the sixteen clamping points The contacts are made of electrolytic copper (ECu), the gray housing is made of polyamide (PA66) for insulation, and the clamping spring is made of a Copper alloy. Tin is used for coating the contact surfaces.

Specification

Notes

Variants:Other pole numbers, Direct marking, Other versions (or variants) can be requested from WAGO Sales or configured at https://configurator.wago.com/.

Electrical data - Ratings per IEC/EN

Ratings perIEC/EN 60664-1
Nominal voltage (III/3)160 V
Rated impulse withstand voltage (III / 3)2.5 kV
Rated voltage (III/2)160 V
Rated impulse withstand voltage (III/2)2.5 kV
Nominal voltage (II/2)320 V
Rated impulse withstand voltage (II/2)2.5 kV
Rated current2 A
Legend (ratings)(III / 2) ≙ Overvoltage category III / Pollution degree 2
Ratings perIEC/EN 60664-1 / IEC/EN 60664-1 / IEC/EN 60664-1
Overvoltage categoryIII / III / II
Pollution degree3 / 2 / 2
Nominal voltage160 V / 160 V / 320 V
Rated impulse withstand voltage2.5 kV / 2.5 kV / 2.5 kV
Rated current2 A / 2 A / 2 A

Electrical data - Ratings per UL

Approvals perUL 1059
Rated voltage UL (Use Group B)300 V
Rated current UL (Use Group B)2 A
Rated voltage UL (Use Group D)300 V
Rated current UL (Use Group D)2 A
Approvals perUL 1059 / UL 1059 / UL 1059
Use groupB / C / D
Rated voltage300 V / 300 V
Rated current2 A / 2 A

Connection data

Clamping units16
Total number of potentials8
Number of connection types1
Number of levels1

Connection data - Connection 1

Connection technologyPUSH WIRE®
Actuation typePush-button
Solid conductor0.14 … 0.5 mm² / 26 … 20 AWG
Conductor diameter0.4 … 0.8 mm / 26 … 20 AWG
Strip length6 … 7 mm / 0.24 … 0.28 inches
Conductor connection direction to PCB0 °
Pole number8

Physical data

Pin spacing3.5 mm / 0.138 inches
Width28 mm / 1.102 inches
Height11 mm / 0.433 inches
Depth10.5 mm / 0.413 inches

Plug-in connection

Contact type (pluggable connector)Female connector/socket
Connector (connection type)for PCB
Plugging without loss of pin spacingYes
Mating direction to the rail-mount terminal block90 °

Material data

Note (material data)Information on material specifications can be found here
Colorgray
Material groupI
Insulation material (main housing)Polyamide (PA66)
Flammability class per UL94V0
Clamping spring materialCopper alloy
Contact materialElectrolytic copper (ECu)
Contact platingTin
Fire load0.076 MJ
Weight3.6 g

Environmental requirements

Limit temperature range-60 … +105 °C

Environmental requirements - Environmental Testing

Test specification: <br/>Railway applications –<br/>Rolling stock –<br/>Electronic equipmentDIN EN 50155 (VDE 0115-200):2022-06
Test procedure: <br/>Railway applications – <br/>Rolling stock equipment – <br/>Vibration and shock testsDIN EN 61373 (VDE 0115-0106):2011-04
Spectrum/Mounting locationService life test, Category 1, Class A/B
Functional test with noise-like oscillationsTest passed according to Section 8 of the standard
Frequencyf1 = 5 Hz to f2 = 150 Hz
Acceleration0.101g (highest test level used for all axes)
Test duration per axis10 min.
Test directionsX, Y and Z axes
Monitoring of contact faults and interruptionsPassed
Voltage drop measurement before and after each axisPassed
Simulated service life test through increased levels of noise-like oscillationsTest passed according to Section 9 of the standard
Frequencyf1 = 5 Hz to f2 = 150 Hz
Acceleration0.572g (highest test level used for all axes)
Test duration per axis5 h
Test directionsX, Y and Z axes
Extended testing: Monitoring of contact faults and interruptionsPassed
Extended testing: Voltage drop measurement before and after each axisPassed
Shock testTest passed according to Section 10 of the standard
Shock pulse formHalf sine
Acceleration5g (highest test level used for all axes)
Shock duration30 ms
Number of shocks (per axis)3 pos. und 3 neg.
Test directionsX, Y and Z axes
Extended testing: Monitoring of contact faults and interruptionsPassed
Extended testing: Voltage drop measurement before and after each axisPassed
Vibration and shock stress for rolling stock equipmentPassed

Commercial data

PU (SPU)200 (50) pcs
Packaging typebox
Country of originPL
GTIN4055143829557
Customs tariff number85366990990

Product Classification

UNSPSC39121409
ETIM 9.0EC002643
ETIM 10.0EC002643
ECCNNO US CLASSIFICATION

Environmental Product Compliance

RoHS Compliance StatusCompliant,No Exemption

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Wago 252-308”