B&R X20DC1178
B&R X20DC1178  624,34
Back to products
B&R X20DC1198
B&R X20DC1198 Price range: € 90,10 through € 316,94

Fast delivery within 72 Hours

B&R X20DC1196

 159,00

13 in stock

1 ABR incremental encoder 5 V2 additional inputs e.g. for home enable switch5 VDC, 24 VDC and GND for encoder supply

The module is equipped with 1 input fo…

13 in stock

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

1 ABR incremental encoder 5 V2 additional inputs e.g. for home enable switch5 VDC, 24 VDC and GND for encoder supply

The module is equipped with 1 input for an ABR incremental encoder with 5 V encoder signal.

Specification

I/O module1 ABR incremental encoder 5 V
B&R ID code0x1BAF
Status indicatorsI/O function per channel, operating state, module status
Module run/errorYes, using LED status indicator and software
Bus0.01 W
Internal I/O1.5 W
Additional power dissipation caused by actuators (resistive) [W]
Type of signal linesShielded lines must be used for all signal lines.
CEYes
UKCAYes
CRA (Cyber Resilience Act)In preparation
ATEXZone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user’s manual) FTZÚ 09 ATEX 0083X
ULcULus E115267 Industrial control equipment
HazLoccCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5
DNVTemperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck)
CCSYes
LRENV1
KRYes
ABSYes
BVEC33B Temperature: 5 – 55°C Vibration: 4 g EMC: Bridge and open deck
KCYes
Quantity2
Nominal voltage24 VDC
Input characteristics per EN 61131-2Type 1
Input voltage24 VDC -15% / +20%
Input current at 24 VDCApprox. 3.3 mA
Input circuitSink
Hardware≤200 ns
Software
Connection type3-wire connections
Input resistance7.19 kΩ
Additional functionsHome enable switch
Low<5 VDC
High>15 VDC
Insulation voltage between channel and bus500 Veff
Encoder inputs5 V, symmetrical
Counter size16/32-bit
Input frequencyMax. 600 kHz
Evaluation4x
5 VDC±5%, module-internal, max. 300 mA
24 VDCModule-internal, max. 300 mA
Common-mode range-7 V ≤ VCM ≤ +12 V
Overload characteristics of encoder power supplyShort-circuit proof, overload-proof
Insulation voltage between encoder and bus500 Veff
Electrical isolationBus isolated from encoder and channel Channel not isolated from channel and encoder
HorizontalYes
VerticalYes
0 to 2000 mNo limitation
>2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP20
Horizontal mounting orientation-25 to 60°C
Vertical mounting orientation-25 to 50°C
Derating
Storage5 to 95%, non-condensing
Transport5 to 95%, non-condensing
Operation5 to 95%, non-condensing
NoteOrder 1x terminal block X20TB12 separately. Order 1x bus module X20BM11 separately.
Pitch12.5+0.2 mm

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “B&R X20DC1196”