Fast delivery within 72 Hours

B&R X20cSO6530

6 safe relay outputsOutput type “Relay”Relay module for 230 VAC / 24 VDCSwitching current 6 ANormally open contactSingle-channel isolated outputs

This modu…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

6 safe relay outputsOutput type “Relay”Relay module for 230 VAC / 24 VDCSwitching current 6 ANormally open contactSingle-channel isolated outputs

This module is equipped with 6 safe relay outputs.The module can be used for controlling floating actuators in safety-related applications up to PL e or SIL 3.Safety relays are installed in the module. The positively driven feedback contacts are evaluated internally by the module. Safe digital output channels provide protection against automatic restart when network errors occur.This module is designed for X20 12-pin terminal blocks.

Specification

I/O module6 relays with 1 normally open contact each, 230 VAC / 2 A (6 A), 24 VDC / 6 A
B&R ID code0x28DE
Status indicatorsI/O function per channel, operating state, module status
Module run/errorYes, using LED status indicator and software
OutputsYes, using LED status indicator and software
ScopeModule
FunctionModule functionality
Standalone modeNo
Max. I/O cycle time1 ms
Bus0.26 W
Internal I/O1.65 W
Additional power dissipation caused by actuators (resistive) [W]4.32
Channel - BusYes
Channel - ChannelYes
CEYes
UKCAYes
CRA (Cyber Resilience Act)In preparation
Functional safetyIEC 61508:2010, SIL 3 EN 62061:2005/A2:2015, SIL 3 EN ISO 13849-1:2015, Cat. 4 / PL e IEC 61511:2004, SIL 3
ATEXZone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user’s manual) FTZÚ 09 ATEX 0083X
ULcULus E115267 Industrial control equipment
EN 50155No
EN 61810-3Yes
NoteOrder 1x safety-keyed terminal block separately. Order 1x safety-keyed bus module separately.
Nominal voltage24 VDC
Voltage range24 VDC -15% / +20%
Integrated protective functionReverse polarity protection
Quantity6
VariantRelay / Normally open contact, internal high-side and low-side control
Nominal output current5 mA to 6 A (hardware revision <B5: 2 A)
Diagnostic statusContact position determined by positively driven contacts
Max. switching frequencySee section “Inrush current behavior for output channels”.
0 → 1<50 ms
1 → 0<50 ms Hardware upgrade 2.2.0.0 or later: <20 ms
Insulation voltage between channel and busSafe disconnection of 300 VAC per EN 50178
Insulation voltage between channel and channelTested at 1350 VAC
Contact resistance (without terminal block)20 mΩ
Contact service lifeSee “Contact service life”.
Short-circuit/Overload protectionExternal 6 A gL/gG fuse (melting fuse), LS automat C characteristic 1.6 A
Switching voltage range5 to 24 VDC, 5 to 230 VAC
Coil voltage24 VDC -15% / +20%
Short-circuit proofYes, 1000 A (with specified short-circuit/overload protection)
Max. inrush currentAC: 50 A for 100 ms, DC: 10 A for 200 ms
Overvoltage category per EN 60664-1II
UL 508B300 / R300
HorizontalYes
VerticalYes
Installation elevation above sea level0 to 2000 m, no limitation
Degree of protection per EN 60529IP20
Horizontal mounting orientation-25 to 60°C
Vertical mounting orientation-25 to 50°C
DeratingSee section “Derating”.
Starting temperatureYes, -25°C
Storage5 to 95%, non-condensing
Transport5 to 95%, non-condensing
OperationUp to 100%, condensing
Pitch25+0.2 mm