B&R X20cSLX402

openSAFETY manager for up to 10 SafeNODEsFlexibly programmable using Automation Studio / SafeDESIGNERInnovative management of safe machine options (SafeOPTION)Parameter and configuration management4 s…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

openSAFETY manager for up to 10 SafeNODEsFlexibly programmable using Automation Studio / SafeDESIGNERInnovative management of safe machine options (SafeOPTION)Parameter and configuration management4 safe digital inputs, sink circuit4 pulse outputsSoftware input filter configurable for each channel2 safe digital outputs, output type B with 0.2 A, source circuitIntegrated output protection

The module is equipped with SafeLOGIC functionality that allows it to safely execute applications designed in SafeDESIGNER. The module can be used in safety-related applications up to PL e or SIL 3.In addition, the module coordinates the safety-related communication of all modules involved in the application. In this context, the module also monitors the configuration of these modules and carries out autonomous parameter downloads to the modules whenever necessary. This guarantees a consistent and correct module configuration in the network from a safety standpoint in all scenarios involving module replacement and service. These services are performed in conjunction with Automation Runtime on the standard CPU.In addition, SafeLOGIC-X products have the same I/O properties as the associated SafeIO products (X20SC0xxx).

Specification

I/O module4 safe type A digital inputs, 4 pulse outputs, 24 VDC, 2 safe type B2 digital outputs, 24 VDC, 0.2 A, OSSD <10 µs, SafeLOGIC-X technology
B&R ID code0xF210
Status indicatorsI/O function per channel, operating state, module status
Module run/errorYes, using LED status indicator and software
OutputsYes, using LED status indicator and software
InputsYes, using LED status indicator and software
ScopeModule
FunctionProgrammable
Standalone modeYes
Max. I/O cycle time1 ms
Bus0.4 W
Internal I/O2.5 W
Safe digital HS-HS outputs0.4
Pulse outputs0.8
Channel - BusYes
Channel - ChannelNo
CEYes
UKCAYes
CRA (Cyber Resilience Act)In preparation
Functional safetyEN 50156-1 in preparation
ATEXZone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user’s manual) FTZÚ 09 ATEX 0083X
ULcULus E115267 Industrial control equipment
NoteOrder 2x safety-keyed terminal block separately. Order 1x safety-keyed bus module separately.
FB instances256
Marker memory5120 bytes (0x1400)
Stack memory4096 bytes
Memory for safe input data128 bytes, 68 bytes of which are usable for modules
Memory for safe output data64 bytes
Memory for standard input data64 bytes
Memory for standard output data64 bytes
Marker count256
Max. number of function block types64
Max. number of force variables8
Max. number of variable with variable status128
Nominal voltage24 VDC
Voltage range24 VDC -15% / +20%
Integrated protective functionReverse polarity protection
Quantity4
VariantPush-Pull
Input characteristics per EN 61131-2Type 1
Hardware≤150 µs
SoftwareConfigurable between 0 and 500 ms
Input circuitSink
Input voltage24 VDC -15% / +20%
Input current at 24 VDCMin. 2 mA to max. 3.28 mA
Input resistanceMin. 7.33 kΩ
Error detection time1 s
Insulation voltage between channel and bus500 Veff
Low<5 VDC
High>15 VDC
Line length between signal source (pulse output or external signal) and inputMax. 60 m with unshielded line Max. 400 m with shielded line
Nominal output current50 mA
Total nominal current200 mA
Output protectionShutdown of individual channels in the event of overload or short circuit
Braking voltage when switching off inductive loadsMax. 45 VDC
Peak short-circuit current0.5 A for 120 µs
Leakage current when the output is switched off0.1 mA
RDS(on)80 Ω
Switching voltageI/O power supply minus voltage drop due to RDS(on)
Max. switching frequencySee section “Inrush current behavior for output channels”.
Test pulse lengthMax. 10 µs
Max. capacitive load100 nF
IOUT<100 µA
IGND<200 mA
Short-circuit current15 mAeff
HorizontalYes
VerticalYes
Installation elevation above sea level0 to 2000 m, no limitation
Degree of protection per EN 60529IP20
Horizontal mounting orientation-25 to 60°C
Vertical mounting orientation-25 to 50°C
DeratingSee section “Derating”.
Starting temperatureYes, -40°C
Storage5 to 95%, non-condensing
Transport5 to 95%, non-condensing
OperationUp to 100%, condensing
Pitch25+0.2 mm