B&R X20CS1012
Power supply for up to 64 slaves on the M-BusDecentralized use of the communication interface
The M-Bus master is designed as a single-width module and can…
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Power supply for up to 64 slaves on the M-BusDecentralized use of the communication interface
The M-Bus master is designed as a single-width module and can be connected anywhere within the X20 I/O system. It can therefore be used decentrally for distributed topologies. The M-Bus master supports transfer rates of 300, 2400 and 9600 bit/s; up to 64 slaves supplied via M-Bus can be connected.M-Bus (Meter-Bus) is a relatively simple fieldbus for recording consumption data, such as from electricity or heat meters. It is based on a reverse polarity protected two-wire line and works according to the master-slave principle.
Specification
| Communication module | 1 M-Bus master for controlling up to 64 slaves |
|---|---|
| B&R ID code | 0xCABF |
| Status indicators | Data transfer, M-Bus power supply, operating state, module status |
| Module run/error | Yes, using LED status indicator and software |
| Data transfer | Yes, using LED status indicator |
| M-Bus power supply | Yes, using LED status indicator and software |
| Bus | 0.2 W |
| Internal I/O | 0.35 W + (Number of slaves * 0.08 W) |
| Module power dissipation | 0.55 W + (Number of slaves * 0.006 W) |
| Additional power dissipation caused by actuators (resistive) [W] | – |
| Insulation voltage between M-Bus and X2X Link | 500 VDC, 1 min |
| CE | Yes |
| UKCA | Yes |
| CRA (Cyber Resilience Act) | In preparation |
| ATEX | Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user’s manual) FTZÚ 09 ATEX 0083X |
| UL | cULus E115267 Industrial control equipment |
| HazLoc | cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5 |
| Type | M-Bus master |
| Variant | Connection via 12-pin terminal block X20TB12 |
| Max. distance | See section “M-Bus”. |
| Transfer rate | 300, 2400 or 9600 bit/s |
| Number of slaves | Max. 64 |
| Internal resistance of master | Max. 6 Ω |
| Bus voltage mark at 0 mA | I/O supply voltage + (11.5 to 13.5) V |
| Bus voltage drop with space | 12 to 13.5 V |
| Overload shutdown | 250 mA ±10% |
| Bit threshold | 6 to 9 mA |
| Collision threshold | 24 to 36 mA |
| Received readjustment time | Max. 10 s |
| Bus cable | Shielded or unshielded |
| Electrical isolation | M-Bus isolated from bus M-Bus not isolated from I/O power supply |
| Horizontal | Yes |
| Vertical | Yes |
| 0 to 2000 m | No limitation |
| >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 | IP20 |
| Horizontal mounting orientation | -25 to 60°C |
| Vertical mounting orientation | -25 to 50°C |
| Derating | – |
| Storage | 5 to 95%, non-condensing |
| Transport | 5 to 95%, non-condensing |
| Operation | 5 to 95%, non-condensing |
| Note | Order 1x terminal block X20TB12 separately. Order 1x bus module X20BM11 separately. |
| Pitch | 12.5+0.2 mm |