Fast delivery within 72 Hours

B&R X20CM0985-02

Energy measurement for 120 to 480 VACSimultaneous measurement of 2 AC power systems plus 2 additional voltagesFor multifunction measurement tasksIntelligent power system synchronization unitCurrent va…

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

2-3 Days

From $20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From $40

  • Warranty 1 year
  • Free 30-Day returns

Description

Energy measurement for 120 to 480 VACSimultaneous measurement of 2 AC power systems plus 2 additional voltagesFor multifunction measurement tasksIntelligent power system synchronization unitCurrent values of generator voltage and currentMonitor functions per current power system guidelines

The module combines a power measurement module with special features in a compact footprint together with a synchronizing unit that meets all requirements.The measurement unit is 3 current inputs are suitable for both X: 1 A and X: 5 A current transformers. Overcurrent resistance and the high resolution of the unit of measurement round off its features. For the voltage inputs, the value range can also be configured between 480 VAC and 120 VAC without any loss in converter resolution. The area of application includes 4-wire AC power systems with a line-to-line voltage up to 480 VAC and 3-wire systems, where L2 can be grounded (V circuit). In addition, the module masters the measuring principle of the Aron circuit. The resulting measured values range from the pure phase current and line-to-line or phase voltage to active, reactive and apparent power components, mains frequency, power factor and much more. In addition, peak values and energy meters are stored on the module in nonvolatile memory. Depending on the configuration, it is also possible to use a digital output as a pulse encoder for an external energy meter. The synchronization unit does not just take the phasing and phase voltage into consideration; integrated intelligence also monitors the rate of change and other parameters, allowing them to influence when the synchronization output is switched. It is also possible to monitor a generator using a large number of additional conditions. A total of 4 voltage inputs provide substantial overall flexibility. Monitoring functions expand the features of the module. Dependent overcurrent monitoring is included, which utilizes the thermal capacity of the motor/generator to allow short overloads while still providing full protection. The dependent, delayed imbalanced load monitoring used to protect three-phase generator and three-phase networks from imbalanced load can be adapted to the characteristics of different generator types using parameters while taking their special thermal time constants into account.

Specification

I/O module

X20 energy measurement and synchronization module

B&R ID code

0xF425

Status indicators

Channel status, operating state, module status

Module run/error

Yes, using LED status indicator and software

Analog inputs

Yes, using LED status indicator (measurement range of analog inputs)

Digital outputs

Yes, using LED status indicator and software

Overvoltage category

ll

Measurement range

15.2 Hz to 2x nominal frequency

Accuracy

Typ. 10 mHz at 400 V / 50 Hz and sinusoidal signals

Bus

1.05 W

Internal I/O

4 W

Additional power dissipation caused by actuators (resistive) [W]

CE

Yes

UKCA

Yes

CRA (Cyber Resilience Act)

In preparation

UL

cULus E115267
Industrial control equipment

UL 6200

Rev. D0
Hardware upgrade 1.5.0.0

Quantity

1

Variant

Relay / Changeover contact

Nominal voltage

30 VDC / 240 VAC

Switching voltage

Max. 60 VDC / 250 VAC

Nominal output current

1 A at 30 VDC / 1 A at 240 VAC

Total nominal current

0.5 A

Connection type

1-wire connections

Output circuit

Source

Output protection

Thermal shutdown in the event of overcurrent or short circuit

Diagnostic status

Output monitoring with 10 ms delay

Leakage current when the output is switched off

5 μA

Residual voltage

<0.3 V at 0.1 A nominal current

Peak short-circuit current

<2 A

Switch-on in the event of overload shutdown or short-circuit shutdown

Approx. 10 ms, depends on the module temperature

0 → 1

≤10 ms

1 → 0

≤10 ms

Resistive load

Max. 100 Hz

Insulation voltage between channel and bus

500 Veff

Rated frequency

DC / 45 to 63 Hz

Min.

10 mA / 5 VDC

Max.

30 W / 240 VAC

Actuator power supply

External

Mechanical

Min. 10 x 106 ops.

Electrical

Min. 60 x 103 ops. (NC) at 1 A
Min. 30 x 103 ops. (NO) at 1 A

Contact resistance

Max. 100 mΩ

Internal

None

External

None

DC

Inverse diode, RC combination or VDR

AC

RC combination or VDR

Channel - Channel

1000 VAC / 1 min

Channel - Bus

4000 VAC / 1 min

Channels

3

Input

1 A / 5 A AC

Input type

Isolated current transformer according to the compensation principle with a magnetic sensor, for connecting an external transformer

Digital converter resolution

±15-bit

50 Hz

10 ms

60 Hz

8.33 ms

Instantaneous values

Corresponds to the X2X cycle time

Permissible input signal

Max. 1.5 A / 7.7 A

±120 VAC

1 LSB = 0x0001 = 5.707 mV

±480 VAC

1 LSB = 0x0001 = 22.787 mV

Overshoot

0x7FFF

Undershoot

0x8001

Conversion method

SAR

Cutoff frequency

10 kHz

Slope

60 dB

Maximum gain drift

0.07% per °C

Maximum offset drift

Measurement range 2 A: 0.0064% per °C, measurement range 10 A: 0.00384% per °C

Crosstalk between channels

-70 dB

Nonlinearity

≤0.5% at 45 to 65 Hz

Protection against electric shock

Protective impedance per EN 61131-2

Test voltage between channel and bus (type test)

3700 Veff

Output format

INT

Input impedance in signal range

Approx. 3 MΩ

Gain

0.2%

Offset

0.05%

Input protection

Overvoltage protection

±1 A

1 LSB = 0x0001 = 189.903 μA

±5 A

1 LSB = 0x0001 = 949.513 μA

Thermal overcurrent

15 x INom for 0.2 s

Monitored overcurrent

4 x INom

Measurement range 1 A

Max. 30 mΩ

Measurement range 5 A

Max. 10 mΩ

Electrical isolation

Bus isolated from I/O power supply and digital inputs and outputs
Digital inputs and outputs isolated from each other

Horizontal

Yes

Vertical

Yes

0 to 2000 m

No limitation

>2000 m

Reduction of ambient temperature by 0.5°C per 100 m

Degree of protection per EN 60529

IP20

Horizontal mounting orientation

-25 to 60°C

Vertical mounting orientation

-25 to 50°C

Derating

See section "Derating".

Storage

5 to 95%, non-condensing

Transport

5 to 95%, non-condensing

Operation

5 to 95%, non-condensing

Note

Order 2x terminal block X20TB12 separately.
Order 2x screw clamp terminal block TB3102 and 2x screw clamp terminal block TB3104 separately.

Pitch

87.5+0.2 mm

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “B&R X20CM0985-02”

Your email address will not be published. Required fields are marked *