B&R X20cAI4622
4 analog inputsEither current or voltage signal possible13-bit digital converter resolution
X20 analog input module, coated, 4 inputs, ±1…
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
4 analog inputsEither current or voltage signal possible13-bit digital converter resolution
X20 analog input module, coated, 4 inputs, ±10 V or 0 to 20 mA / 4 to 20 mA, 13-bit converter resolution, configurable input filter
Specification
| I/O module | 4 analog inputs ±10 V or 0 to 20 mA / 4 to 20 mA |
|---|---|
| B&R ID code | 0xE1EF |
| Status indicators | I/O function per channel, operating state, module status |
| Module run/error | Yes, using LED status indicator and software |
| Inputs | Yes, using LED status indicator and software |
| Channel type | Yes, using software |
| Bus | 0.01 W |
| Internal I/O | 1.1 W |
| Additional power dissipation caused by actuators (resistive) [W] | – |
| CE | Yes |
| UKCA | Yes |
| CRA (Cyber Resilience Act) | In preparation |
| ATEX | Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user’s manual) FTZÚ 09 ATEX 0083X |
| UL | cULus E115267 Industrial control equipment |
| HazLoc | cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5 |
| DNV | Temperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck) |
| LR | ENV1 |
| KR | Yes |
| ABS | Yes |
| BV | EC33B Temperature: 5 – 55°C Vibration: 4 g EMC: Bridge and open deck |
| Input | ±10 V or 0 to 20 mA / 4 to 20 mA, via different terminal connections |
| Input type | Differential input |
| Voltage | <0.025% |
| Current | <0.05% |
| Conversion time | 400 μs for all inputs |
| Output format | INT |
| Input protection | Protection against wiring with supply voltage |
| Output of digital value during overload | Configurable |
| Conversion procedure | SAR |
| Input filter | Third-order low-pass filter / Cutoff frequency 1 kHz |
| Gain | 0 to 20 mA = 0.08% / 4 to 20 mA = 0.1% |
| Offset | 0 to 20 mA = 0.03% / 4 to 20 mA = 0.0375% |
| DC | 70 dB |
| 50 Hz | 70 dB |
| Common-mode range | ±12 V |
| Crosstalk between channels | <-70 dB |
| Insulation voltage between channel and bus | 500 Veff |
| Electrical isolation | Channel isolated from bus Channel not isolated from channel |
| Horizontal | Yes |
| Vertical | Yes |
| 0 to 2000 m | No limitation |
| >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 | IP20 |
| Horizontal mounting orientation | -25 to 60°C |
| Vertical mounting orientation | -25 to 50°C |
| Derating | – |
| Starting temperature | Yes, -40°C |
| Storage | 5 to 95%, non-condensing |
| Transport | 5 to 95%, non-condensing |
| Operation | Up to 100%, condensing |
| Note | Order 1x terminal block X20TB12 separately. Order 1x bus module X20cBM11 separately. |
| Pitch | 12.5+0.2 mm |