Fast delivery within 72 Hours
B&R X20BC1083
POWERLINKI/O configuration and firmware update via the fieldbusIntegrated hub for efficient cablingUp to 2 slots for interface modules
The bus controller m…
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
POWERLINKI/O configuration and firmware update via the fieldbusIntegrated hub for efficient cablingUp to 2 slots for interface modules
The bus controller makes it possible to connect X2X Link I/O nodes to POWERLINK. It is also possible to operate the X2X Link cycle synchronously 1:1 or synchronous to POWERLINK using a prescaler. POWERLINK is a standard protocol for Fast Ethernet equipped with hard real-time characteristics. The POWERLINK Standardization Group (EPSG) ensures that the standard remains open and is continually developed:: www.ethernet-powerlink.org.The bus modules expanded to the left allow connection of up to 2 interface modules in addition to the bus controller.
Specification
| Bus controller | POWERLINK (V1/V2) controlled node with up to 2 slots for interface modules |
|---|---|
| B&R ID code | 0x2268 |
| Status indicators | Module status, bus function |
| Module status | Yes, using LED status indicator and software |
| Bus function | Yes, using LED status indicator and software |
| Dynamic node allocation (DNA) | Yes |
| Bus | 2 W |
| Additional power dissipation caused by actuators (resistive) [W] | – |
| CE | Yes |
| UKCA | Yes |
| CRA (Cyber Resilience Act) | In preparation |
| ATEX | Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user’s manual) FTZÚ 09 ATEX 0083X |
| UL | cULus E115267 Industrial control equipment |
| HazLoc | cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5 |
| DNV | Temperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck) |
| CCS | Yes |
| LR | ENV1 |
| KR | Yes |
| ABS | Yes |
| BV | EC33B Temperature: 5 – 55°C Vibration: 4 g EMC: Bridge and open deck |
| KC | Yes |
| Fieldbus | 200 μs |
| Type | Type 2 |
| Variant | 2x shielded RJ45 (hub) |
| Line length | Max. 100 m between 2 stations (segment length) |
| Transfer rate | 100 Mbit/s |
| Physical layer | 100BASE-TX |
| Half-duplex | Yes |
| Full-duplex | No |
| Autonegotiation | Yes |
| Auto-MDI/MDIX | Yes |
| Hub propagation delay | 0.96 to 1 µs |
| X2X Link | 200 μs |
| Synchronization between bus systems possible | Yes |
| Input data | Max. 1488 bytes |
| Output data | Max. 1488 bytes |
| Electrical isolation | POWERLINK isolated from bus and I/O |
| Horizontal | Yes |
| Vertical | Yes |
| 0 to 2000 m | No limitation |
| >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 | IP20 |
| Horizontal mounting orientation | -25 to 60°C |
| Vertical mounting orientation | -25 to 50°C |
| Derating | – |
| Storage | 5 to 95%, non-condensing |
| Transport | 5 to 95%, non-condensing |
| Operation | 5 to 95%, non-condensing |
| Note | Order 1x terminal block X20TB12 separately. Order 1x power supply module X20PS9400 or X20PS9402 separately. Order 1x bus base X20BB81 or X20BB82 separately. |
| X20BB81 | 62.5+0.2 mm |
| X20BB82 | 87.5+0.2 mm |

Reviews
Clear filtersThere are no reviews yet.