Back to products
B&R X20BC0083
B&R X20BC0083 Price range: € 68,90 through € 143,10

Fast delivery within 72 Hours

B&R X20BC0073

Fieldbus: CAN busAutomatic firmware update via the fieldbusIntegrated I/O access in B&R Automation StudioIntegrated terminating resistor

The bus controller…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Fieldbus: CAN busAutomatic firmware update via the fieldbusIntegrated I/O access in B&R Automation StudioIntegrated terminating resistor

The bus controller makes it possible to connect X2X Link I/O nodes to CAN I/O. CAN I/O is a transfer protocol based on standard CAN bus that is fully integrated in the B&R system.Up to 43 logic I/O modules can be connected to the bus controller. Up to 16 of them can be analog modules.With multifunction modules, the bus controller supports only the default function model in the event of automatic configuration by the bus controller (see the respective module description).

Specification

Bus controllerCAN I/O slave
B&R ID code0x1F1D
Status indicatorsModule status, bus function, data transfer, terminating resistor
Module statusYes, using LED status indicator and software
Bus functionYes, using LED status indicator
Data transferYes, using LED status indicator
Terminating resistorIntegrated in module
Bus1.5 W
Additional power dissipation caused by actuators (resistive) [W]
CEYes
UKCAYes
CRA (Cyber Resilience Act)In preparation
ATEXZone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user’s manual) FTZÚ 09 ATEX 0083X
ULcULus E115267 Industrial control equipment
HazLoccCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5
KCYes
FieldbusCAN I/O slave
Variant5-pin male multipoint connector
Max. distance1000 m
Transfer rateMax. 1 Mbit/s
Default transfer rateAutomatic transfer rate detection or fixed setting
Synchronization between bus systems possibleNo
Electrical isolationCAN I/O isolated from I/O CAN I/O not isolated from bus
HorizontalYes
VerticalYes
0 to 2000 mNo limitation
>2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP20
Horizontal mounting orientation-25 to 60°C
Vertical mounting orientation-25 to 50°C
Derating
Storage5 to 95%, non-condensing
Transport5 to 95%, non-condensing
Operation5 to 95%, non-condensing
NoteOrder 1x terminal block TB2105 separately. Order 1x terminal block X20TB12 separately. Order 1x power supply module X20PS9400 or X20PS9402 separately. Order 1x bus base X20BB80 separately.
Pitch37.5+0.2 mm

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “B&R X20BC0073”