B&R X20AP3111

Calculates RMS values from currents and voltagesCalculates active, reactive and apparent powerPhasing detectionMeasures individual phases and calculates cumulative valuesOptional measurement of curren…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Calculates RMS values from currents and voltagesCalculates active, reactive and apparent powerPhasing detectionMeasures individual phases and calculates cumulative valuesOptional measurement of current through the neutral conductorCalculates frequency and harmonics with high precisionNetTime timestamp: Moment when measured value groups are read

Power monitoringThese modules measure active, reactive and apparent power individually for each of the 3 phases as well as all of them collectively. The power consumption of each phase is also recorded individually and in total. In addition, the modules provide the RMS values for voltage and current on the 3 phases. When measuring the current, the value of the current through the neutral conductor can also be detected and monitored. Measurement of the mains frequency and the phase angle of the 3 phases (current and voltage) complete the power measurement data.Energy managementThe integrated functions on the modules map the immediate power requirements of the machine in detail as well as record its total power consumption. For the user, all relevant data is prepared and made available in the process image.The ability to measure currents and voltages up to the 31st harmonic enables higher precision recording of RMS values than is generally possible. This allows the modules to easily cope with irregular sine curves and makes them well-suited to renewable energy applications. In these types of applications, for example, being able to accurately measure the frequency at a resolution of 0.01 Hz between 45 and 65 Hz is a great advantage. In general, the modules are suitable for use with 1-phase, 2-phase or 3-phase networks.NetTime timestamp of readout momentsFor many applications, not only the measured value is important, but also the exact moment when a group of measured values is read out. The module is equipped with a NetTime timestamp function for this that supplies a timestamp for the recorded position and trigger time with microsecond accuracy.The timestamp function is based on synchronized timers. If a timestamp event occurs, the module immediately saves the current NetTime. After the respective data is transferred to the CPU, including this precise moment, the CPU can then evaluate the data using its own NetTime (or system time), if necessary.

Specification

I/O module3-phase power and energy metering module for current transformers
B&R ID code0xC9DA
Status indicatorsI/O function per channel, operating state, module status
Module run/errorYes, using LED status indicator and software
InputsYes, using LED status indicator and software
Bus0.85 W (Rev. D0)
Internal I/O
Additional module power dissipation [W]40 mW
Inputs - Bus / I/O power supplyTested at 5500 VDC, 1 min
Inputs - GroundTested at 5500 VDC, 1 min
Bus / I/O power supply - GroundTested at 510 VAC, 1 min
CEYes
UKCAYes
CRA (Cyber Resilience Act)In preparation
ATEXZone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user’s manual) FTZÚ 09 ATEX 0083X
ULcULus E115267 Industrial control equipment
HazLoccCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5
DNVTemperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck)
CCSYes
LRENV1
KRYes
ABSYes
BVEC33B Temperature: 5 – 55°C Vibration: 4 g EMC: Bridge and open deck
Number of phases3
Input impedance1.68 MΩ
Between phasesMax. 480 VAC
Phase to NMax. 277 VAC
Max. display value655 VAC
Resolution1 mA, based on the primary current
Rated frequency50 and 60 Hz
Measurement range45 to 65 Hz
Quantity4 AC inputs
Secondary20 mA
Primary65 A directly configurable, larger values through conversion in the application
Max. overload current20 x IN for 0.5 s
Max. measuring current20 mA
Load25 Ω
URMS±0.65%
IRMS±0.65%
Effective, reactive and apparent power±0.80%
Frequency, power factor and phase angle±0.50%
Active energy per phase and total±0.40%
Active energy of fundamental frequency per phase and total±0.50%
Active energy of harmonics per phase and total±0.80%
Reactive energy per phase and total±0.50%
Per phase and arithmetic total±0.50%
Vector sum±0.80%
Electrical isolationChannel isolated from bus Channel not isolated from channel
HorizontalYes
VerticalYes
0 to 2000 mNo limitation
>2000 mNot permitted
Degree of protection per EN 60529IP20
Horizontal mounting orientation-25 to 60°C
Vertical mounting orientation-25 to 50°C
Derating
Storage5 to 95%, non-condensing
Transport5 to 95%, non-condensing
Operation5 to 95%, non-condensing
NoteOrder 1x terminal block X20TB32 separately. Order 1x bus module X20BM32 separately.
Pitch25+0.2 mm