Fast delivery within 72 Hours

B&R X20AO2438

2 analog current outputsHART protocol integrationSupport for HART variablesElectrically isolated analog channels16-bit digital converter resolutionOSP modeNetTime timestamp: HART image…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

2 analog current outputsHART protocol integrationSupport for HART variablesElectrically isolated analog channels16-bit digital converter resolutionOSP modeNetTime timestamp: HART image

The module is equipped with 2 current outputs with 16-bit digital converter resolution. It supports the HART communication standard for data transfer, parameter configuration and diagnostics.The 2 channels are electrically isolated from each other. The user can select between the 3 output ranges 4 to 20 mA, 0 to 20 mA and 0 to 24 mA.

Specification

I/O module2 analog outputs 4 to 20 mA, 0 to 20 mA or 0 to 24 mA
B&R ID code0xB3AA
Status indicatorsI/O function per channel, operating state, module status, HART
Module run/errorYes, using LED status indicator and software
OutputsYes, using LED status indicator and software
HART errorYes, using LED status indicator and software
Bus0.05 W
Internal I/O1.65 W
Additional power dissipation caused by actuators (resistive) [W]
CEYes
UKCAYes
CRA (Cyber Resilience Act)In preparation
ATEXZone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user’s manual) FTZÚ 09 ATEX 0083X
ULcULus E115267 Industrial control equipment
HazLoccCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5
DNVTemperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck)
CCSYes
LRENV1
KRYes
ABSYes
BVEC33B Temperature: 5 – 55°C Vibration: 4 g EMC: Bridge and open deck
KCYes
Output4 to 20 mA, 0 to 20 mA or 0 to 24 mA configurable using software
Digital converter resolution16-bit
Settling time on output change over entire range2 ms to 20 s, configurable using software
With HART210 ms (default)
Analog1 ms without ramp
4 to 20 mA0.14%
0 to 20 mA0.1%
0 to 24 mA0.1%
Output protectionShort-circuit proof, overvoltage protection (up to 30 VDC)
Open-circuit detectionYes, using hardware and software
Data formatINT
Load per channelMax. 600 Ω
Short-circuit proofYes, continuous
Output filterActive second-order low-pass filter / Cutoff frequency 19 Hz Configurable slew rate
Nonlinearity<0.003%
Channel - Channel1000 VAC
Channel - Bus1000 VAC
Channel - Ground1000 VAC
Transfer rate1200 bit/s
Operating frequencies1200 Hz / 2200 Hz
Burst operation possibleYes
PossibleYes
StationsUp to 15
Minimum120 mVpp
Typical500 mVpp
Maximum1500 mVpp
Electrical isolationChannel isolated from channel and bus
HorizontalYes
VerticalYes
0 to 2000 mNo limitation
>2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP20
Horizontal mounting orientation-25 to 60°C
Vertical mounting orientation-25 to 50°C
DeratingSee section “Derating”.
Storage5 to 95%, non-condensing
Transport5 to 95%, non-condensing
Operation5 to 95%, non-condensing
NoteOrder 1x terminal block X20TB12 separately. Order 1x bus module X20BM11 separately.
Pitch12.5+0.2 mm

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “B&R X20AO2438”