Fast delivery within 72 Hours
B&R VFC42040.000P
Machine vision flash controller, 4 channels each 20 A for external lighting, trigger inputs and outputs per channel, IP65/IP67 protection, POWERLINK interface with integrated 2-port hub
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
From $20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From $40
-
Warranty 1 year
-
Free 30-Day returns
Description
Machine vision flash controller, 4 channels each 20 A for external lighting, trigger inputs and outputs per channel, IP65/IP67 protection, POWERLINK interface with integrated 2-port hub
Specification
| Accessories |
Flash controller |
|---|---|
| Cooling |
Passive |
| Diagnostics |
Yes, using LED "Status" and software |
| Undervoltage detection |
Yes |
| Reverse polarity protection |
Yes |
| CE |
Yes |
| CRA (Cyber Resilience Act) |
In preparation |
| Connection |
M12, 4-pin, L-coded, male |
| Nominal voltage |
24 VDC -15% / +20% |
| Max. input current |
8 A |
| Quantity |
4 |
| Connection designation |
IF3, IF4, IF5, IF6 |
| Fieldbus |
POWERLINK |
| Type |
POWERLINK (V2) managing or controlled node |
| Variant |
M12, 5-pin, A-coded, female |
| Line length |
Max. 30 m between 2 stations (segment length) |
| Transfer rate |
100 Mbit/s |
| Physical layer |
100BASE-TX |
| Half-duplex |
Yes |
| Full-duplex |
No |
| Autonegotiation |
Yes |
| Auto-MDI/MDIX |
Yes |
| Min. cycle time |
400 µs |
| Input characteristics per EN 61131-2 |
Type 1 |
| Input voltage |
24 VDC -15% / +20% |
| Input current at 24 VDC |
Typ. 3.7 mA |
| Input circuit |
Sink/Source |
| Input resistance |
Typ. 6.5 kΩ |
| Low |
<5 VDC |
| High |
>15 VDC |
| Channel - Channel |
Yes |
| Channel - Power supply |
Yes |
| 0 → 1 |
<1 µs |
| 1 → 0 |
<1 µs |
| Output circuit |
Push / Pull / Push-Pull |
| Leakage current when the output is switched off |
Max. 200 µA |
| RDS(on) |
Max. 0.1 Ohm |
| Max. output current |
100 mA |
| Electrical isolation |
No |
| Short-circuit proof |
Yes |
| Overtemperature shutdown |
Yes |
| Max. cable length |
20 m |
| Max. line inductance |
10 µH |
| Min. output voltage |
5 V |
| Max. output voltage |
48 V |
| Per channel |
10 kHz |
| All channels |
96 W |
| Current setting step size |
5 mA |
| Voltage setting step size |
50 mV |
| Voltage measurement resolution |
50 mV |
| At 20 A output current |
4% |
| Min. pulse duration |
1 µs |
| Configurable |
4147 s |
| At full load, 1 channel |
4 ms |
| At full load, all 4 channels simultaneously |
1 ms |
| At 250 mA output current |
100% |
| All 4 channels simultaneously |
20 kHz |
| Horizontal |
Yes |
| Vertical |
Yes |
| Face-up |
Yes |
| 0 to 2000 m |
No limitations |
| >2000 m |
Reduction of ambient temperature by 0.5°C per 100 m |
| Pollution degree per EN 60664-1 |
2 |
| Overvoltage category per EN 60664-1 |
II |
| Degree of protection per EN 60529 |
IP67 |
| Operation |
5 to 100%, condensing |
| Storage |
5 to 95%, non-condensing |
| Transport |
5 to 95%, non-condensing |
| Material |
Aluminum die casting |
| Width |
270.0 mm |
| Length |
186.0 mm |
| Height |
65.1 mm |

Reviews
Clear filtersThere are no reviews yet.